Ranganathan Rani Hemamalini
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ranganathan Rani Hemamalini has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
- Pachaivannan Partheeban
Department of Civil Engineering, Chennai Institute of Technology, Chennai, India
9 shared publications - K. P. Indira
Sathyabama University, Chennai - 600 119, Tamil Nadu
3 shared publications N. Sowri Raja Pillai
St. Peters Institute of Higher Education and Research
3 shared publications- P. Grace Kanmani Prince
Sathyabama University
3 shared publications - Sumathi Sokkanarayanan
Sri Sairam Engineering College,Department of Electronics and Communication Engineering,Chennai,India
3 shared publications - K. Anbumani
Sathyabama Institute of Science and Technology, Chennai, India
2 shared publications
Latest Publications
- 9 October 2026
- Published by Elsevier in Next Research
- Vol. 14
Condition monitoring of DC-link capacitor in back-to-back power converters using distributed convolutional neural network
- 9 October 2026
- Published by Elsevier in Next Research
- Vol. 14
Condition monitoring of DC-link capacitor in back-to-back power converters using distributed convolutional neural network
- Open Access
- 6 April 2026
- Published by Elsevier in Measurement: Energy
- Vol. 10
Hierarchical temporal memory-based predictive maintenance of DC-link capacitors in power electronic converters
- 6 April 2026
- Published by Elsevier in Measurement: Energy
- Vol. 10
Open AccessHierarchical temporal memory-based predictive maintenance of DC-link capacitors in power electronic converters
- Open Access
- 12 November 2024
- Published by MDPI AG in Sustainability
- Vol. 16 (22) , 9848
Groundwater Quality Prediction and Analysis Using Machine Learning Models and Geospatial Technology
The most prominent source of drinking water is groundwater, followed by lakes and reservoirs. Hydrological parameters like temperature, dissolved oxygen, pH, conductivity, ORP, and turbidity often change due to waste dumping into natural drinking water sources, particularly in densely populated areas. As a result, the water quality must be tested before public consumption to ensure healthy living in society. This research collected water samples from 129 wells in the Kanchipuram district in Tamil Nadu, India. An efficient integrated machine-learning-based prediction model has been proposed and modeled to determine the groundwater quality index (GQI). Several machine learning models were used to predict the water’s quality, including the naïve Bayes model, the KNN classifier, and the XGBoost classifier. Water quality predictions in 2024 were made using a combination of classification algorithms and models based on long short-term memory (LSTM) neural networks. The projected water quality characteristics were analyzed using geographical information system (GIS) technology to better understand and visualize the results. The XGBoost classifier model outperforms prior findings in the literature, with an accuracy of roughly 94.6%. The classification and prediction model was validated using collected and tested current data samples from a selected well. The findings were accurate within the 5% error range, promoting sustainability.
- 12 November 2024
- Published by MDPI AG in Sustainability
- Vol. 16 (22) , 9848
Open AccessGroundwater Quality Prediction and Analysis Using Machine Learning Models and Geospatial Technology
The most prominent source of drinking water is groundwater, followed by lakes and reservoirs. Hydrological parameters like temperature, dissolved oxygen, pH, conductivity, ORP, and turbidity often change due to waste dumping into natural drinking water sources, particularly in densely populated areas. As a result, the water quality must be tested before public consumption to ensure healthy living in society. This research collected water samples from 129 wells in the Kanchipuram district in Tamil Nadu, India. An efficient integrated machine-learning-based prediction model has been proposed and modeled to determine the groundwater quality index (GQI). Several machine learning models were used to predict the water’s quality, including the naïve Bayes model, the KNN classifier, and the XGBoost classifier. Water quality predictions in 2024 were made using a combination of classification algorithms and models based on long short-term memory (LSTM) neural networks. The projected water quality characteristics were analyzed using geographical information system (GIS) technology to better understand and visualize the results. The XGBoost classifier model outperforms prior findings in the literature, with an accuracy of roughly 94.6%. The classification and prediction model was validated using collected and tested current data samples from a selected well. The findings were accurate within the 5% error range, promoting sustainability.
- 16 October 2024
- Published by Elsevier in Measurement
- Vol. 242
Assessment of harmful gases emission and its impact using IoT and geospatial technology
- 16 October 2024
- Published by Elsevier in Measurement
- Vol. 242
Assessment of harmful gases emission and its impact using IoT and geospatial technology
- Open Access
- 6 September 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (18) , 13347
Air Quality Monitoring and Analysis for Sustainable Development of Solid Waste Dump Yards Using Smart Drones and Geospatial Technology
Air pollution has become a global health issue, affecting millions of people annually. It is essential to obtain accurate and up-to-date information on air quality levels to reduce the impact of air pollution on human health. Traditional air quality monitoring methods are limited by spatial coverage and the time required for sample collection and analysis. However, the Internet of Things (IoT), drone technology, and Geographic Information System (GIS) technology have enabled the development of real-time air quality monitoring systems that provide accurate and up-to-date information on air quality levels across large areas. The study found that gas concentration varied significantly at different heights, with the highest concentration at 3 m from the ground and the lowest at 9 m. The concentration of gases also varied by month, with the highest concentration of CO recorded in March at 45 ppm at 3 m, and the highest concentration of NH4 recorded in September at 66.7 ppm at 3 m. Kodungaiyur dump yard needs environmental monitoring due to the high levels of environmental pollution and health risks caused by unsegregated waste. In conclusion, developing real-time air quality monitoring systems using GIS technology is necessary to obtain accurate and up-to-date information on air quality levels. It is essential to monitor the Kodungaiyur dump yard and other, similar sites regularly to prevent the health risks associated with environmental pollution.
- 6 September 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (18) , 13347
Open AccessAir Quality Monitoring and Analysis for Sustainable Development of Solid Waste Dump Yards Using Smart Drones and Geospatial Technology
Air pollution has become a global health issue, affecting millions of people annually. It is essential to obtain accurate and up-to-date information on air quality levels to reduce the impact of air pollution on human health. Traditional air quality monitoring methods are limited by spatial coverage and the time required for sample collection and analysis. However, the Internet of Things (IoT), drone technology, and Geographic Information System (GIS) technology have enabled the development of real-time air quality monitoring systems that provide accurate and up-to-date information on air quality levels across large areas. The study found that gas concentration varied significantly at different heights, with the highest concentration at 3 m from the ground and the lowest at 9 m. The concentration of gases also varied by month, with the highest concentration of CO recorded in March at 45 ppm at 3 m, and the highest concentration of NH4 recorded in September at 66.7 ppm at 3 m. Kodungaiyur dump yard needs environmental monitoring due to the high levels of environmental pollution and health risks caused by unsegregated waste. In conclusion, developing real-time air quality monitoring systems using GIS technology is necessary to obtain accurate and up-to-date information on air quality levels. It is essential to monitor the Kodungaiyur dump yard and other, similar sites regularly to prevent the health risks associated with environmental pollution.
- Retraction
- 4 July 2022
- Published by Springer Nature in Journal of Ambient Intelligence and Humanized Computing
- Vol. 14 (S1) , 609
Retraction Note to: Decentralised fractional order pi decontroller tuned using grey wolf optimization for three interacting cylindrical tanks
- 4 July 2022
- Published by Springer Nature in Journal of Ambient Intelligence and Humanized Computing
- Vol. 14 (S1) , 609
RetractionRetraction Note to: Decentralised fractional order pi decontroller tuned using grey wolf optimization for three interacting cylindrical tanks
- 1 January 2022
- Published by Zarqa University in The International Arab Journal of Information Technology
- Vol. 19 (6) , 956-964
Hybrid User Acceptance Test Procedure to Improve the Software Quality
- 1 January 2022
- Published by Zarqa University in The International Arab Journal of Information Technology
- Vol. 19 (6) , 956-964
Hybrid User Acceptance Test Procedure to Improve the Software Quality
- Retracted
- 25 May 2020
- Published by Springer Nature in Journal of Ambient Intelligence and Humanized Computing
- Vol. 12 (5) , 5561-5569
RETRACTED ARTICLE: Decentralised fractional order pi decontroller tuned using grey wolf optimization for three interacting cylindrical tanks
- 25 May 2020
- Published by Springer Nature in Journal of Ambient Intelligence and Humanized Computing
- Vol. 12 (5) , 5561-5569
RetractedRETRACTED ARTICLE: Decentralised fractional order pi decontroller tuned using grey wolf optimization for three interacting cylindrical tanks
- 2 January 2020
- Published by Taru Publications in Journal of Statistics and Management Systems
- Vol. 23 (1) , 103-112
Nonlinear process control of anaerobic sludge digester
Anaerobic absorption is a sequence of processes by which microbes separate decomposable wastes without oxygen. They convert the decomposable wastes in the form of carbon dioxide and water. Due to the nonlinear nature of the anaerobic process several control strategies are used to adjust the manipulated inputs to maintain the process outputs at desired set points. The objective of this work is to achieve the desired sludge temperature level of the anaerobic digester using PI (Proportional Integral), PID (Proportional-Integral-Derivative) Control and Fuzzy Logic Control (FLC). The comparative study indicates that the Fuzzy Logic Control is enhanced over conventional PID Control. The designed system can also be implemented using BFOA (Bacterial Foraging Optimization Algorithm) to optimize the operation and in tuning of PID controller parameters for an anaerobic digester.
- 2 January 2020
- Published by Taru Publications in Journal of Statistics and Management Systems
- Vol. 23 (1) , 103-112
Nonlinear process control of anaerobic sludge digester
Anaerobic absorption is a sequence of processes by which microbes separate decomposable wastes without oxygen. They convert the decomposable wastes in the form of carbon dioxide and water. Due to the nonlinear nature of the anaerobic process several control strategies are used to adjust the manipulated inputs to maintain the process outputs at desired set points. The objective of this work is to achieve the desired sludge temperature level of the anaerobic digester using PI (Proportional Integral), PID (Proportional-Integral-Derivative) Control and Fuzzy Logic Control (FLC). The comparative study indicates that the Fuzzy Logic Control is enhanced over conventional PID Control. The designed system can also be implemented using BFOA (Bacterial Foraging Optimization Algorithm) to optimize the operation and in tuning of PID controller parameters for an anaerobic digester.
- Open Access
- 10 November 2019
- Published by Blue Eyes Intelligence Engineering and Sciences Engineering and Sciences Publication (BEIESP) in International Journal of Innovative Technology and Exploring Engineering
- Vol. 9 (1) , 2953-2957
Research on Power Efficient Clock Distribution Schemes for Switching Converters
Trends in VLSI technology represents bottleneck for the future high performance computing architectures as the ratio of the power pins to the total package pins keeps on increasing. A viable solution to this is bottleneck is to have final power consumption on-chip. Switched Capacitor DC-DC Converters are the most preferred for on-chip power conversion. However, as the number of power conversion modules increases and they get distributed across the chip area, clock distribution for the switched capacitor converters becomes a non-trivial task and the increased interconnect lengths cause clock degradation and power dissipation. This paper presents a power efficient signaling topology for driving the clocks to higher interconnect lengths.
- 10 November 2019
- Published by Blue Eyes Intelligence Engineering and Sciences Engineering and Sciences Publication (BEIESP) in International Journal of Innovative Technology and Exploring Engineering
- Vol. 9 (1) , 2953-2957
Open AccessResearch on Power Efficient Clock Distribution Schemes for Switching Converters
Trends in VLSI technology represents bottleneck for the future high performance computing architectures as the ratio of the power pins to the total package pins keeps on increasing. A viable solution to this is bottleneck is to have final power consumption on-chip. Switched Capacitor DC-DC Converters are the most preferred for on-chip power conversion. However, as the number of power conversion modules increases and they get distributed across the chip area, clock distribution for the switched capacitor converters becomes a non-trivial task and the increased interconnect lengths cause clock degradation and power dissipation. This paper presents a power efficient signaling topology for driving the clocks to higher interconnect lengths.