MRMitesh Rathod

Mitesh Rathod

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mitesh Rathod has a total of 44 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Nuclear SUN2 coordinates endothelial cell-matrix interactions to regulate blood vessel homeostasis and barrier function

    by Pauline Bougaran, Danielle B Buglak, Alexandra Neal, Mitesh Rathod, Michaelanthony Gore, Max A Hockenberry, Aryan A Amin, Natalie Tanke, Morgan Oatley, Wesley R Legant, et al.

    Vascular endothelial cells respond to environmental forces to remodel vessels during development and to achieve homeostasis, and mis-regulated responses lead to vascular dysfunction and disease. The nucleus participates in force transduction to cell-matrix junctions via the Linker of Nucleoskeleton and Cytoskeleton (LINC) complex that resides in the nuclear envelope, but how these forces are regulated and relayed is incompletely understood. We found that the LINC complex protein SUN2 is required for proper endothelial cell-matrix interactions that occur far from the nucleus and affect angiogenic expansion, vascular responses to flow, and barrier integrity. Endothelial cells lacking SUN2 had inappropriate flow responses and reduced expression of flow-mediated transcription factors in vitro and in vivo . Expression of several matrix and adhesion genes was reduced in SUN2-depleted cells, leading to defective extracellular matrix, dysmorphic focal adhesions resistant to dynamic turnover, and disturbed cell-matrix force distribution. Mechanistically, nuclear SUN2 affected dynamic regulation of the microtubule cytoskeleton that correlated with matrix metalloprotease-dependent barrier dysfunction. These findings indicate that nuclear SUN2 establishes and maintains blood vessel homeostasis by controlling microtubule-mediated effects on focal adhesion turnover and extracellular matrix properties, with implications for cardiovascular aging and diseases such as Marfan syndrome that affect vessel wall integrity.

  • Open Access

    Dysfunctional mechanotransduction regulates the progression of PIK3CA-driven vascular malformations

    by Wen Yih Aw, Aanya Sawhney, Mitesh Rathod, Chloe P. Whitworth, Elizabeth L. Doherty, Ethan Madden, Jingming Lu, Kaden Westphal, Ryan Stack, William J. Polacheck

    Somatic activating mutations in PIK3CA are common drivers of vascular and lymphatic malformations. Despite common biophysical signatures of tissues susceptible to lesion formation, including compliant extracellular matrix and low rates of perfusion, lesions vary in clinical presentation from localized cystic dilatation to diffuse and infiltrative vascular dysplasia. The mechanisms driving the differences in disease severity and variability in clinical presentation and the role of the biophysical microenvironment in potentiating progression are poorly understood. Here, we investigate the role of hemodynamic forces and the biophysical microenvironment in the pathophysiology of vascular malformations (VMs), and we identify hemodynamic shear stress and defective endothelial cell mechanotransduction as key regulators of lesion progression. We found that constitutive PI3K activation impaired flow-mediated endothelial cell alignment and barrier function. We show that defective shear stress sensing in PIK3CAE542K endothelial cells is associated with reduced myosin light chain phosphorylation, junctional instability, and defective recruitment of vinculin to cell–cell junctions. Using three dimensional (3D) microfluidic models of the vasculature, we demonstrate that PIK3CAE542K microvessels apply reduced traction forces and are unaffected by flow interruption. We further found that draining transmural flow resulted in increased sprouting and invasion responses in PIK3CAE542K microvessels. Mechanistically, constitutive PI3K activation decreased cellular and nuclear elasticity resulting in defective cellular tensional homeostasis in endothelial cells which may underlie vascular dilation, tissue hyperplasia, and hypersprouting in PIK3CA-driven venous and lymphatic malformations. Together, these results suggest that defective nuclear mechanics, impaired cellular mechanotransduction, and maladaptive hemodynamic responses contribute to the development and progression of PIK3CA-driven vascular malformations.


  • Open Access

    Dysfunctional mechanotransduction regulates the progression of PIK3CA-driven vascular malformations

    by Wen Yih Aw, Aanya Sawhney, Mitesh Rathod, Chloe P. Whitworth, Elizabeth L. Doherty, Ethan Madden, Jingming Lu, Kaden Westphal, Ryan Stack, William J. Polacheck

    Somatic activating mutations in PIK3CA are common drivers of vascular and lymphatic malformations. Despite common biophysical signatures of tissues susceptible to lesion formation, including compliant extracellular matrix and low rates of perfusion, lesions vary in clinical presentation from localized cystic dilatation to diffuse and infiltrative vascular dysplasia. The mechanisms driving the differences in disease severity and variability in clinical presentation and the role of the biophysical microenvironment in potentiating progression are poorly understood. Here, we investigate the role of hemodynamic forces and the biophysical microenvironment in the pathophysiology of vascular malformations, and we identify hemodynamic shear stress and defective endothelial cell mechanotransduction as key regulators of lesion progression. We found that constitutive PI3K activation impaired flow-mediated endothelial cell alignment and barrier function. We show that defective shear stress sensing in PIK3CA E542K endothelial cells is associated with reduced myosin light chain phosphorylation, junctional instability, and defective recruitment of vinculin to cell-cell junctions. Using 3D microfluidic models of the vasculature, we demonstrate that PIK3CA E542K microvessels apply reduced traction forces and are unaffected by flow interruption. We further found that draining transmural flow resulted in increased sprouting and invasion responses in PIK3CA E542K microvessels. Mechanistically, constitutive PI3K activation decreased cellular and nuclear elasticity resulting in defective cellular tensional homeostasis in endothelial cells which may underlie vascular dilation, tissue hyperplasia, and hypersprouting in PIK3CA -driven venous and lymphatic malformations. Together, these results suggest that defective nuclear mechanics, impaired cellular mechanotransduction, and maladaptive hemodynamic responses contribute to the development and progression of PIK3CA -driven vascular malformations.


  • Open Access

    A facile fluid pressure system reveals differential cellular response to interstitial pressure gradients and flow

    by Hao Wang, Jingming Lu, Mitesh Rathod, Wen Yih Aw, Stephanie A. Huang, William J. Polacheck

    Interstitial fluid pressure gradients and interstitial flow have been shown to drive morphogenic processes that shape tissues and influence progression of diseases including cancer. The advent of porous media microfluidic approaches has enabled investigation of the cellular response to interstitial flow, but questions remain as to the critical biophysical and biochemical signals imparted by interstitial fluid pressure gradients and resulting flow on resident cells and extracellular matrix (ECM). Here, we introduce a low-cost method to maintain physiological interstitial fluid pressures that is built from commonly accessible laboratory equipment, including a laser pointer, camera, Arduino board, and a commercially available linear actuator. We demonstrate that when the system is connected to a microfluidic device containing a 3D porous hydrogel, physiologic pressure is maintained with sub-Pascal resolution and when basic feedback control is directed using an Arduino, constant pressure and pressure gradient can be maintained even as cells remodel and degrade the ECM hydrogel over time. Using this model, we characterized breast cancer cell growth and ECM changes to ECM fibril structure and porosity in response to constant interstitial fluid pressure or constant interstitial flow. We observe increased collagen fibril bundling and the formation of porous structures in the vicinity of cancer cells in response to constant interstitial fluid pressure as compared to constant interstitial flow. Collectively, these results further define interstitial fluid pressure as a driver of key pathogenic responses in cells, and the systems and methods developed here will allow for future mechanistic work investigating mechanotransduction of interstitial fluid pressures and flows.


  • Open Access

    Multilayer microfluidic platform for the study of luminal, transmural, and interstitial flow

    by Gi-Hun Lee, Stephanie A Huang, Wen Y Aw, Mitesh L Rathod, Crescentia Cho, Frances S Ligler, William J Polacheck

    Efficient delivery of oxygen and nutrients to tissues requires an intricate balance of blood, lymphatic, and interstitial fluid pressures (IFPs), and gradients in fluid pressure drive the flow of blood, lymph, and interstitial fluid through tissues. While specific fluid mechanical stimuli, such as wall shear stress, have been shown to modulate cellular signaling pathways along with gene and protein expression patterns, an understanding of the key signals imparted by flowing fluid and how these signals are integrated across multiple cells and cell types in native tissues is incomplete due to limitations with current assays. Here, we introduce a multi-layer microfluidic platform (MμLTI-Flow) that enables the culture of engineered blood and lymphatic microvessels and independent control of blood, lymphatic, and IFPs. Using optical microscopy methods to measure fluid velocity for applied input pressures, we demonstrate varying rates of interstitial fluid flow as a function of blood, lymphatic, and interstitial pressure, consistent with computational fluid dynamics (CFD) models. The resulting microfluidic and computational platforms will provide for analysis of key fluid mechanical parameters and cellular mechanisms that contribute to diseases in which fluid imbalances play a role in progression, including lymphedema and solid cancer.


  • Ultra‐Sensitive and Highly Stretchable Strain Sensors for Monitoring of Human Physiology

    by Ravi Prakash Verma, Prateekshya Suman Sahu, Mitesh Rathod, Soumya Sanjeeb Mohapatra, Junghoon Lee, Biswajit Saha

    The flexible strain sensors have potential applications in advanced electronics, health monitoring systems, wearable sensors, robotics, and human–machine interfaces. The development of highly sensitive, stretchable, and durable strain sensors is a challenging task for researchers. However, the sensors with a detection range from large strain to minute deflection are imperative for human‐interactive applications. This work has demonstrated a facile method of sensor fabrication, which use reduced graphene oxide (rGO) as sensing material and silicone sealant as a flexible substrate. Few‐layer rGO is synthesized by electrochemical exfoliation of pencil lead. The fabricated sensors have a gauge factor higher than 4000 and durability longer than 1600 cycles at 100% strain. At the same time, developed strain sensors exhibit detection capability over a wide range of strain (0–120%), which is an essential requirement of wearable sensors. To the best of the authors’ knowledge, fewer works have reported strain sensors that have ultra‐high gauge factor (≥4000) in combination with high stretchability (>100%). Utilizing the ultra‐sensitivity and sub‐second response time of the rGO‐sealants, these wearable sensors are used to monitor physical activities, heartbeats, and finger touches.


  • PDMS Sylgard 527-Based Freely Suspended Ultrathin Membranes Exhibiting Mechanistic Characteristics of Vascular Basement Membranes

    by Mitesh L. Rathod, Jungho Ahn, Biswajit Saha, Prashant Purwar, Yejin Lee, Noo Li Jeon, Junghoon Lee

    In the past significant effort has been made to develop ultrathin membranes exhibiting physiologically relevant mechanical properties, such as thickness and elasticity, of native basement membranes. However, most of these fabricated membranes have relatively high elastic modulus, ~MPa - GPa, relevant only to retinal and epithelial basement membranes. Vascular basement membranes exhibiting relatively low elastic modulus, ~kPa, on the contrary, have seldom been mimicked. Membranes demonstrating high compliance, moduli ranging in ~kPa along with submicroscale thicknesses have rarely been reported, and would be ideal to mimic vascular basement membranes in vitro. To address this, we fabricate ultrathin membranes demonstrating the mechanistic features exhibited by their vascular biological counterparts. Salient features of the fabricated ultrathin membranes include free suspension, physiologically relevant thickness ~submicrometres, relatively low modulus ~kPa, and sufficiently large culture area ~20 mm2. To fabricate such ultrathin membranes, undiluted PDMS Sylgard 527 was utilised as opposed to the conventional diluted polymer-solvent mixture approach. In addition, the necessity to have sacrificial layer for releasing membranes from the underlying substrates was also eliminated in our approach. The novelty of our work lies in achieving the distinct combination of membranes having thickness in sub-micrometres and the associated elasticity in kPa using undiluted polymer, which past approaches with dilution have not been able to accomplish. The ultrathin membranes with average thickness of 972 nm (thick) and 570 nm (thin) were estimated to have an elastic modulus of 45 kPa and 214 kPa respectively. Contact angle measurements revealed the ultrathin membranes exhibited hybrophobic characteristics in unpeeled state and transformed to hydrophilic behaviour when freely suspended. Human Umbilical Vein Endothelial Cells were cultured on the polymeric ultrathin membranes and the temporal cell response to change in local compliance of the membranes was studied by evaluating cell spread area, density, percentage area coverage and spread rate. After 24 hours, single cells, pairs and group of three to four cells were noticed on highly compliant thick membranes, having average thickness of 972 nm and modulus of 45 kPa. On the contrary, cell monolayer was noted on glass slide acting as a control. For the thin membranes, featuring average thickness of 570 nm and modulus of 214 kPa, the cells tend to exhibit similar response to that on control with initiation of monolayer formation. Our results indicate, the local compliance, in turn, the membrane thickness governs the cell behaviour and this can have vital implications during disease initiation and progression, wound healing and cancer cell metastasis.


  • Open Access

    Engineered ridge and micropillar array detectors to quantify the directional migration of fibroblasts

    by Mitesh L. Rathod, Nikhil Pareek, Suchi Agrawal, Siddhartha Jaddivada, Dong W. Lee, Namrata Gundiah

    Cell migrations on substrates are important in diverse processes such as wound healing, embryogenesis, and pathologies like cancer metastasis. An understanding of the cellular mechanobiology during migration requires development of suitable engineering platforms to better represent the anisotropic in vivo cellular environment and measure traction forces due to cell adhesion. We fabricated a custom elastomeric micropillar array detector (mPAD), comprised of alternate ridge and pillar topographical features, using a lithographic fabrication method that creates an anisotropic microenvironment and also permits the measurement of traction forces. We used the finite element method to compare predictions of calculated tractions for pillar geometries with different aspect ratios using linear and nonlinear constitutive models. These simulations showed the importance of pillar aspect ratios and constitutive models in computing resulting tractions. We cultured 3T3 fibroblasts on the engineered mPAD and characterized cellular migrations over a three hour period. Our results show highly elongated cellular and nuclear morphologies on the mPAD substrates as compared to cells cultured on control elastomeric substrates. Cells on mPADs demonstrated persistent directional motion along ridges as compared to random movements on control substrates. These results showed the importance of substrate anisotropy in the alignment of fibroblasts on mPAD. We also measured differences in the cellular tractions along the length of the cell on mPAD substrates. Engineered mPADs are hence useful in directing cellular motions and in delineating mechanobiological processes during adhesion and migration.


  • Hybrid polymer microfluidic platform to mimic varying vascular compliance and topology

    by M. L. Rathod, J. Ahn, N. L. Jeon, J. Lee

    Several cardiovascular pathologies and aging have been associated with alterations in the mechanical and structural properties of the vascular wall, leading to a reduction in arterial compliance and the development of constriction. In the past, rare efforts have been directed to understand the endothelial cell response to combined mechanical stimuli from fluid flow and substrate rigidity. Recent approaches using microfluidic platforms have limitations in precisely mimicking healthy and diseased vasculature conditions from altered topological and substrate compliance perspectives. To address this, we demonstrated an effective fabrication process to realize a hybrid polymer platform to test these mechanistic features of blood vessels. The salient features of the platform include circular microchannels of varying diameters, variation in substrate rigidity along the channel length, and the coexistence of microchannels with different cross sections on a single platform. The platform demonstrates the combined effects of flow-induced shear forces and substrate rigidity on the endothelial cell layer inside the circular microchannels. The experimental results indicate a pronounced cell response to flow induced shear stress via its interplay with the underlying substrate mechanics.