Sanjib Gogoi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sanjib Gogoi has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Aashish Kumar Singh
Department of Medicine, Lady Hardinge Medical College & Associated Hospitals, New Delhi, India
1 shared publicationAnsu Kumari
Department of Microbiology, Lady Hardinge Medical College & Associated Hospitals, New Delhi, India
1 shared publicationAnupam Prakash
Department of Medicine, Lady Hardinge Medical College & Associated Hospitals, New Delhi, India
1 shared publication- Ashish William
Department of Microbiology, Lady Hardinge Medical College & Associated Hospitals, New Delhi, India. Pin-110001
1 shared publication - Deepti Rawat
Department of Microbiology, Lady Hardinge Medical College & Associated Hospitals, New Delhi-110001, Delhi, India
1 shared publication Ghanshyam Pangtey
Department of Medicine, Lady Hardinge Medical College & Associated Hospitals, New Delhi, India
1 shared publication
Latest Publications
- Open Access
- 1 August 2025
- Published by Microbiology Society in Access Microbiology
- Vol. 7 (8) , 000643.v5
Comparative evaluation of GeneXpert and reverse transcription polymerase chain reaction for SARS-CoV-2 diagnosis: a retrospective study
Background. The novel coronavirus disease 2019 (COVID-19) has highlighted vulnerabilities in healthcare systems and has brought the world to a standstill single-handedly. Diagnostic testing for COVID-19 is critical for understanding epidemiology, contact tracing, case management and controlling the transmission of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Real-time reverse transcription PCR test, the gold standard test, involves fairly complex steps and takes nearly 24–48 h to generate the results. GeneXpert is a rapid nucleic-acid-detection-based test approved by the Indian Council of Medical Research, which can shorten the turnaround time significantly. Aim. The study aimed to compare the performance of GeneXpert against the gold standard real-time reverse transcription PCR for SARS-CoV-2. Materials and methods. This retrospective study was conducted at a tertiary care centre from 25 March 2020 to 8 December 2020. The nasopharyngeal/oropharyngeal swabs that were sent to the Viral Research and Diagnostic Laboratory for testing of SARS-CoV-2 by GeneXpert [cartridge-based nucleic acid amplification test (CBNAAT)] were included for the study. A total of 270 samples (220 samples positive and 50 samples negative for SARS-CoV-2 by GeneXpert) were simultaneously tested for real-time reverse transcription PCR. Real-time reverse transcription PCR was considered as gold standard test (reference) for calculating the sensitivity and specificity of the GeneXpert (CBNAAT) test. Results. Out of the total samples tested (n=270) for SARS-CoV-2, 220 were positive, and 50 were negative for SARS-CoV-2 by GeneXpert. Among 220 GeneXpert SARS-CoV-2-positive samples, 118 (53.64%) were also positive by real-time reverse transcription PCR, while 102 (46.36%) showed negative results by real-time reverse transcription PCR. However, 50 GeneXpert negative samples showed 100% agreement with real-time reverse transcription PCR, i.e. they were also negative by real-time reverse transcription PCR. The GeneXpert sensitivity and specificity for COVID-19 were seen to be 100% (95% CI: 96.92–100%) and 32.89% (95% CI: 25.50–40.97%), respectively, as compared to the gold standard real-time reverse transcription PCR test. The positive predictive value and negative predictive value of GeneXpert for COVID-19 were found to be 53.64% and 100%, respectively. Conclusion. This study highlights that the GeneXpert test is highly sensitive and found to be useful in emergency and challenging situations for rapidly ruling out negative cases. However, due to its relatively low specificity, positive results should be confirmed with real-time reverse transcription PCR. Therefore, it can serve as a valuable tool for patients requiring urgent care by facilitating early diagnosis and management of COVID-19, ultimately contributing to preventing morbidity and mortality.
- 1 August 2025
- Published by Microbiology Society in Access Microbiology
- Vol. 7 (8) , 000643.v5
Open AccessComparative evaluation of GeneXpert and reverse transcription polymerase chain reaction for SARS-CoV-2 diagnosis: a retrospective study
Background. The novel coronavirus disease 2019 (COVID-19) has highlighted vulnerabilities in healthcare systems and has brought the world to a standstill single-handedly. Diagnostic testing for COVID-19 is critical for understanding epidemiology, contact tracing, case management and controlling the transmission of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Real-time reverse transcription PCR test, the gold standard test, involves fairly complex steps and takes nearly 24–48 h to generate the results. GeneXpert is a rapid nucleic-acid-detection-based test approved by the Indian Council of Medical Research, which can shorten the turnaround time significantly. Aim. The study aimed to compare the performance of GeneXpert against the gold standard real-time reverse transcription PCR for SARS-CoV-2. Materials and methods. This retrospective study was conducted at a tertiary care centre from 25 March 2020 to 8 December 2020. The nasopharyngeal/oropharyngeal swabs that were sent to the Viral Research and Diagnostic Laboratory for testing of SARS-CoV-2 by GeneXpert [cartridge-based nucleic acid amplification test (CBNAAT)] were included for the study. A total of 270 samples (220 samples positive and 50 samples negative for SARS-CoV-2 by GeneXpert) were simultaneously tested for real-time reverse transcription PCR. Real-time reverse transcription PCR was considered as gold standard test (reference) for calculating the sensitivity and specificity of the GeneXpert (CBNAAT) test. Results. Out of the total samples tested (n=270) for SARS-CoV-2, 220 were positive, and 50 were negative for SARS-CoV-2 by GeneXpert. Among 220 GeneXpert SARS-CoV-2-positive samples, 118 (53.64%) were also positive by real-time reverse transcription PCR, while 102 (46.36%) showed negative results by real-time reverse transcription PCR. However, 50 GeneXpert negative samples showed 100% agreement with real-time reverse transcription PCR, i.e. they were also negative by real-time reverse transcription PCR. The GeneXpert sensitivity and specificity for COVID-19 were seen to be 100% (95% CI: 96.92–100%) and 32.89% (95% CI: 25.50–40.97%), respectively, as compared to the gold standard real-time reverse transcription PCR test. The positive predictive value and negative predictive value of GeneXpert for COVID-19 were found to be 53.64% and 100%, respectively. Conclusion. This study highlights that the GeneXpert test is highly sensitive and found to be useful in emergency and challenging situations for rapidly ruling out negative cases. However, due to its relatively low specificity, positive results should be confirmed with real-time reverse transcription PCR. Therefore, it can serve as a valuable tool for patients requiring urgent care by facilitating early diagnosis and management of COVID-19, ultimately contributing to preventing morbidity and mortality.
- Open Access
- 22 December 2021
- Published by Knowledge E DMCC in Iranian Journal of Microbiology
- Vol. 13 (6) , 748-756
Comparative evaluation of cost effective extraction free molecular technique for detection of SARS-CoV-2 with reference to standard VTM based RT-qPCR method
Background and Objectives: The entire globe is undergoing an unprecedented challenge of COVID-19. Considering the need of rapid and accurate diagnostic tests for SARS-CoV-2, this study was planned to evaluate the cost effective extraction free RT-PCR technique in comparison to the standard VTM based RT-qPCR method. Materials and Methods: Paired swabs from nasopharynx and oropharynx were collected for SARS-CoV-2 testing, from 211 adult patients (≥18 years) in VTM and plain sterile tubes (dry swabs). These samples were processed and RT-qPCR was carried out as per standard protocols. Results: 54.5% of the patients were females and 45.5% were males with sex ratio 1:1.19 (M: F). 38.86% were symptomatic, of which fever (86.59%), cough (79.23%) and breathlessness (46.34%) were the most common symptoms. The positivity by VTM based method and index method was 31.27% and 13.27% respectively. Of the 27 inconclusive results from index method, 37.04% were positive, 48.15% were negative by VTM based method. However, in 40 inconclusive results by VTM based method, 90% were negative and rest remained inconclusive by index method. The sensitivity and specificity of the index method were 39.39% and 85.71% respectively. The overall agreement between VTM based method and index method was 49.59% with estimated Kappa value of 0.19. Conclusion: VTM based method showed higher sensitivity compared to the index method. The higher positivity by VTM based method, suggests that VTM based method could plausibly be a better detection method of SARS-CoV-2. Still, the index method might add value in a resource limited setups for detection of SARS-CoV-2.
- 22 December 2021
- Published by Knowledge E DMCC in Iranian Journal of Microbiology
- Vol. 13 (6) , 748-756
Open AccessComparative evaluation of cost effective extraction free molecular technique for detection of SARS-CoV-2 with reference to standard VTM based RT-qPCR method
Background and Objectives: The entire globe is undergoing an unprecedented challenge of COVID-19. Considering the need of rapid and accurate diagnostic tests for SARS-CoV-2, this study was planned to evaluate the cost effective extraction free RT-PCR technique in comparison to the standard VTM based RT-qPCR method. Materials and Methods: Paired swabs from nasopharynx and oropharynx were collected for SARS-CoV-2 testing, from 211 adult patients (≥18 years) in VTM and plain sterile tubes (dry swabs). These samples were processed and RT-qPCR was carried out as per standard protocols. Results: 54.5% of the patients were females and 45.5% were males with sex ratio 1:1.19 (M: F). 38.86% were symptomatic, of which fever (86.59%), cough (79.23%) and breathlessness (46.34%) were the most common symptoms. The positivity by VTM based method and index method was 31.27% and 13.27% respectively. Of the 27 inconclusive results from index method, 37.04% were positive, 48.15% were negative by VTM based method. However, in 40 inconclusive results by VTM based method, 90% were negative and rest remained inconclusive by index method. The sensitivity and specificity of the index method were 39.39% and 85.71% respectively. The overall agreement between VTM based method and index method was 49.59% with estimated Kappa value of 0.19. Conclusion: VTM based method showed higher sensitivity compared to the index method. The higher positivity by VTM based method, suggests that VTM based method could plausibly be a better detection method of SARS-CoV-2. Still, the index method might add value in a resource limited setups for detection of SARS-CoV-2.