RYRavi Shankar Yalavarthy

Ravi Shankar Yalavarthy

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ravi Shankar Yalavarthy has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Patient perspectives on tooth replacement: A cross-sectional survey

    by Sai Krishna Athota, K. Varun Reddy, Harikrishna Modalavalasa, Bhargavi Katta, Ravi Shankar Yalavarthy, Prachi Krishna Kant Pandey

    Awareness, attitudes, knowledge and preferences regarding tooth replacement among 200 adults aged 30–70 years using a validated 26-item questionnaire is of interest. Results showed that 66% of participants had a positive attitude towards treatment and 5% of participants showed negative awareness, while 38% demonstrated good awareness and 29% had poor understanding of available options. Socio-demographic factors are including age, education, affordability, influenced decisions and expectations. The findings highlight the need for targeted awareness programs to improve knowledge and encourage early adoption of dental prosthetic care in adult population.


  • Open Access

    Effect of multiple reuse of commonly used implant analogs on the dimensional accuracy and the marginal gap between analog and abutment – An in vitro study

    by Ravi Shankar Yalavarthy, Jagadeesh Naidu Alla, Srinivas Kalluri, Shiva Shankar Mahadevan, M Hari Krishna, P Shameen Kumar

    Statement of Problem: During the impression procedure, the implant's exact position in the oral cavity is transferred into the cast using impression post and implant analog. As the implant, analog is a lab component, it can be reused multiple times. Reuse of implant analogs may be desirable for both environmental and financial aspects. When implant analogs are reused, it is important to be assured that they are as accurate as new ones. Reusing of implant analog results in loss of precision which is the major key factor in the failure of implant prosthesis. Purpose of the Study: The purpose of the present in vitro study is to assess the effect of multiple reuse of implant analogs of three different materials (SS, Ti, Al) on the dimensional accuracy (external and internal diameter) of implant analogs and the marginal gap between analog and abutment by using two die materials at different time intervals (0, 3rd, 6th, 9th, and 12th). Materials and Methods: Three commonly used implant analog materials (stainless steel, titanium, and aluminum) and two type – IV die stone materials (Kalrock and Zhermack elite) are used to make the samples. A total of sixty implant analogs (20 each), sixty corresponding abutments (20 each) and 720 screws (240 each) were taken, which includes stainless steel, titanium, and aluminum manufactured by Adin, Genesis, and Equinox/Myriad plus, respectively. Addition silicone (light body consistency) was used to make an impression for the internal thread of implant analogues. The obtained samples are tested for external diameter and internal diameter of implant analogues, the marginal gap between analogue and abutment while reusing the implant analogues at the interval of times (0, 3rd, 6th, 9th, and 12th) using a stereomicroscope at ×50. Here the measured values at “0” interval were considered as the control group. The values obtained were statistically analyzed using the one-way ANOVA, independent t-test, and dependent t-test for multiple comparisons. Results: Based on the results obtained, there was no change in the external diameter of three materials of implant analog in both die materials. There was an increase in the internal diameter of implant analogs in which the aluminum material exhibits more increase from 0 to 12th interval, and there was an increase discrepancy in the marginal gap between implant analog and abutment in which the aluminum material has more increase from 0 to 12th interval followed by the stainless steel and titanium implant analogs in both die materials. In between the two die materials, no significant difference was observed in all three parameters. Conclusion: From the study, the following inferences are drawn: that titanium implant analogs can be used more than three times but not more than six times, stainless steel implant analogs can be used for not more than three times, and the aluminum implant analogs can be used for one time only. Hence, among the three materials, titanium implant analogs were most efficient for reuse. Clinical implications: Micromovements of the abutment screw due to discrepancy or loss of surface details of threads of implant analog leads to micro-leakage and bacterial infiltration due to marginal gap discrepancy which further causes increased inflammation at the connection level contributing to a marginal bone loss that may affect the long-term success of implant prosthesis/implant.

  • Open Access

    Effect of multiple reuse of commonly used implant analogs on the changes in the distance between internal threads: An in vitro study

    by Ravi Shankar Yalavarthy, Jagadeesh Naidu Alla, Srinivas Kalluri, Shiva Shankar Mahadevan, Satyendra Kumar, Sunitha Ronanki

    Aim: To assess the effect of multiple reuse of implant analogs of three different materials (SS, Ti, Al) on the changes in the distance between internal threads of implant analog by using two die materials at different time intervals (0, 3rd, 6th, 9th, and 12th). Settings and Design: An in vitro study. Materials and Methodology: Three commonly used implant analog materials (stainless steel, titanium, and aluminum) and two Type– IV die stone materials (Kalrock and Zhermack Elite) were used to make the samples. A total of sixty implant analogs (20 each), sixty corresponding abutments (20 each) and 720 screws (240 each) were taken, which includes stainless steel, titanium, and aluminum manufactured by Adin, Genesis, and Equinox/Myriad plus, respectively. In addition, silicone (light body consistency) was used to make an impression for the internal thread of implant analogs. The obtained samples were tested for changes in the internal threads of implant analogs while reusing the implant analogs at the interval of times (0, 3rd, 6th, 9th, and 12th) using a stereomicroscope at ×50. Here, the measured values at “0” interval were considered the control group. Statistical Analysis Used: The values obtained were statistically analyzed using One way ANOVA, independent t test, and dependent t test for multiple comparisons. Results: Based on the results obtained, the overall comparison of the mean distance between threads 1–2, 3–4, and 5–6 on the replica of internal threads of the stainless steel, titanium, and aluminum implant analog materials at 1–2 has more decrease in distance from 0 to 12th intervals, at 3–4 has less amount of decrease in distance than thread distance at 1–2 from 0 to 12th intervals, and at 5–6 has very less decrease in distance than thread distance at 1–2 and 3–4 from 0 to 12th intervals. On order the mean distance reduction between threads is more at 1–2, followed to that less reduction at 3–4 and very less reduction at 5–6. This infers that the amount of increase in the distance between the internal threads of implant analog at 1–2 has more followed by 3–4 and 5–6, respectively. Conclusion: From the study, the following inferences are drawn: That the aluminum implant analog internal threads have more amount of increase in the distance between threads followed by stainless steel and titanium. Hence, among the three materials, titanium implant analogs were most efficient for reuse.


  • Open Access

    Prosthodontic Treatment Using Vital and Non Vital Submerged Roots-Two Case Reports

    by Y. Ravi Shankar

    Journal of Clinical and Diagnostic Research aims to publish findings of doctors at grass root level and post graduate students, so that all unique medical experiences are recorded in literature.