TOTakahiro Okawa

Takahiro Okawa

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Takahiro Okawa has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Direct insertion of the posterior cruciate ligament tibial attachment and its relationship with the medial meniscus: A histological study

    by Akihiro Yamashita, Kosuke Tabuchi, Ryuki Hashida, Keishiro Kikuchi, Shotaro Kinouchi, Seiichi Inoue, Takashi Soejima, Akira Maeda, Shuji Horibe, Koichi Watanabe, et al.

    Purpose: In this study, we aimed to identify the direct insertion of the tibial attachment of the posterior cruciate ligament (PCL) using histological examination and evaluate its anatomical relationship with the medial meniscus (MM). Methods: Twenty‐one formalin‐fixed cadaveric knees were examined. The PCL tibial attachment was analysed in sagittal (slices 1, 2 and 3) and coronal (slices 4, 5, 6 and 7) sections. Hematoxylin and eosin and Masson's trichrome staining were used for tissue evaluation. The tibial insertion length and direct insertion length were measured using ImageJ software. The relationship between direct insertion and anatomical parameters was analysed using Spearman's correlation coefficient. Results: The mean medial anteroposterior length was 52.1 ± 3.7 mm. The mean tibial insertion lengths of the PCL were 9.8 ± 1.7 mm (slice 1), 10.8 ± 1.1 mm (slice 2) and 8.5 ± 0.9 mm (slice 3). The mean direct insertion lengths were 8.5 ± 1.4 mm (slice 1), 9.7 ± 1.0 mm (slice 2) and 7.5 ± 0.9 mm (slice 3). Direct insertion in slice 2 was significantly correlated with medial anteroposterior length ( p < 0.05). In the sagittal plane, the MM posterior root was adjacent to the anterior edge of the PCL tibial insertion, with a clear bony change‐point at the border. In the coronal plane, the medial tibial plateau and PCL were separated by the MM tibial attachment (slices 5 and 6). Conclusions: The tibial attachment area of the PCL was shorter than that reported in previous gross anatomical studies. These findings provide important anatomical insights for PCL reconstruction and are essential for preventing iatrogenic MM injuries during tibial tunnel creation. Level of Evidence: N/A.

  • Open Access

    Posterior decentering of the humeral head in patients with arthroscopic rotator cuff repair

    by Hidehiro Nakamura, Masafumi Gotoh, Hirokazu Honda, Yasuhiro Mitsui, Hiroki Ohzono, Naoto Shiba, Shinichiro Kume, Takahiro Okawa

    Background: In some patients with rotator cuff tear (RCT), the axial view of magnetic resonance imaging (MRI) shows subtle posterior decentering (PD) of the humeral head from the glenoid fossa. This is considered to result from a loss of centralization that is typically produced by rotator cuff function. There are few reports on PD in RCT despite the common occurrence of posterior subluxation in degenerative joint disease. In this study, we investigated the effect of PD in arthroscopic rotator cuff repair (ARCR). Methods: We conducted a retrospective study of consecutive patients who underwent ARCR at our institute and were followed-up for at least 1 year. PD was identified as a 2-mm posterior shift of the humeral head relative to the glenoid fossa in the axial MRI view preoperatively. The tear size and fatty degeneration (FD, Goutallier classification) were also evaluated using preoperative MRI. Retears were evaluated through MRI at 1 year postoperatively. Results: We included 135 shoulders in this study. Ten instances of PD (including seven retears) were observed preoperatively. Fifteen retears (three and 12 retears in the small/medium and large/massive tear groups, respectively) were observed postoperatively. PD was significantly correlated with tear size, FD, and retear occurrence (p= 3 cm and FD grade >= 3. Conclusions: We concluded that large tear size and FD contribute to the occurrence of PD. Furthermore, PD could be a predictor of retear after ARCR.