Takuya Okada
Takuya Okada has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Junji Morita
Department of Cardiology Sapporo Cardiovascular Clinic Sapporo Hokkaido Japan
2 shared publications Takayuki Kitai
Department of Cardiovascular Medicine, Sapporo Heart Center Sapporo Cardiovascular Clinic Sapporo Japan
2 shared publicationsTsutomu Fujita
Department of Cardiovascular Medicine, Sapporo Heart Center Sapporo Cardiovascular Clinic Sapporo Japan
2 shared publicationsFumiya Uchida
Division of Cardiology, Mie Heart Center , Meiwa
1 shared publication- Hiroyuki Kato
Department of Cardiology, Japan Community Healthcare Organization Chukyo Hospital, Nagoya, Japan
1 shared publication - Hitoshi Mori
Department of Cardiology Saitama Medical University International Medical Center Hidaka Saitama Japan
1 shared publication
Latest Publications
- Open Access
- 1 November 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (11)
Anatomical vs. electrophysiological approach for ablation of premature ventricular contractions originating from the left ventricular summit (ISESHIMA-SUMMIT Study)
Aims: Catheter ablation (CA) of idiopathic ventricular arrhythmias (VAs) from the epicardial left ventricular summit is challenging. The endocardial approach targets two sites: the endocardial closest site (ECS) to the epicardial earliest activation site (epi-EAS) and the endocardial earliest activation site (endo-EAS). We aimed to differentiate between cases where CA at the ECS was effective and where CA at the endo-EAS yielded success. Methods and results: Fifty-eight patients (47 men; age 60 ± 13 years) were analysed with VAs in which the EAS was observed in the coronary venous system (CVS). Overall, VAs were successfully eliminated in 42 (72%) patients: 8 in the CVS, 8 where the ECS matched with the endo-EAS, 11 at the ECS, and 15 at the endo-EAS. A successful ECS ablation was associated with a shorter epi-EAS–ECS distance (10.2 ± 4.7 vs. 18.8 ± 5.3 mm; P < 0.001) and shorter epi-EAS–left main coronary trunk (LMT) ostial distance (20.3 ± 7.6 vs. 30.3 ± 8.4 mm; P = 0.005), with optimal cut-off values of ≤12.6 and ≤24.0 mm, respectively. A successful endo-EAS ablation was associated with an earlier electrogram at the endo-EAS [23 (8, 36) vs. 15 (0, 19) ms preceding the QRS; P < 0.001] and shorter epi-EAS–endo-EAS interval [6 (1, 8) vs. 22 (12, 25) ms; P < 0.001], with optimal cut-off values of ≥18 and ≤9 ms, respectively. Conclusion: Shorter anatomical distances between the epi-EAS and ECS, and between the epi-EAS and LMT ostium, predict a successful ECS ablation. The prematurity of the endo-EAS electrogram and a shorter interval between the epi-EAS and endo-EAS predicted a successful endo-EAS ablation.
- 1 November 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (11)
Open AccessAnatomical vs. electrophysiological approach for ablation of premature ventricular contractions originating from the left ventricular summit (ISESHIMA-SUMMIT Study)
Aims: Catheter ablation (CA) of idiopathic ventricular arrhythmias (VAs) from the epicardial left ventricular summit is challenging. The endocardial approach targets two sites: the endocardial closest site (ECS) to the epicardial earliest activation site (epi-EAS) and the endocardial earliest activation site (endo-EAS). We aimed to differentiate between cases where CA at the ECS was effective and where CA at the endo-EAS yielded success. Methods and results: Fifty-eight patients (47 men; age 60 ± 13 years) were analysed with VAs in which the EAS was observed in the coronary venous system (CVS). Overall, VAs were successfully eliminated in 42 (72%) patients: 8 in the CVS, 8 where the ECS matched with the endo-EAS, 11 at the ECS, and 15 at the endo-EAS. A successful ECS ablation was associated with a shorter epi-EAS–ECS distance (10.2 ± 4.7 vs. 18.8 ± 5.3 mm; P < 0.001) and shorter epi-EAS–left main coronary trunk (LMT) ostial distance (20.3 ± 7.6 vs. 30.3 ± 8.4 mm; P = 0.005), with optimal cut-off values of ≤12.6 and ≤24.0 mm, respectively. A successful endo-EAS ablation was associated with an earlier electrogram at the endo-EAS [23 (8, 36) vs. 15 (0, 19) ms preceding the QRS; P < 0.001] and shorter epi-EAS–endo-EAS interval [6 (1, 8) vs. 22 (12, 25) ms; P < 0.001], with optimal cut-off values of ≥18 and ≤9 ms, respectively. Conclusion: Shorter anatomical distances between the epi-EAS and ECS, and between the epi-EAS and LMT ostium, predict a successful ECS ablation. The prematurity of the endo-EAS electrogram and a shorter interval between the epi-EAS and endo-EAS predicted a successful endo-EAS ablation.
- Open Access
- 22 August 2023
- Published by Wiley in Journal of Arrhythmia
- Vol. 39 (5) , 803-806
Oversensing caused by trapped air in the header of subcutaneous cardioverter‐defibrillator generator
In this study, we report two cases with oversensing due to air accumulation in the subcutaneous implantable cardioverter‐defibrillator (S‐ICD) device generator header. If trapped air in the header of the device is suspected, the re‐connection procedure should be considered or the primary vector must be used, which might prevent oversensing.
- 22 August 2023
- Published by Wiley in Journal of Arrhythmia
- Vol. 39 (5) , 803-806
Open AccessOversensing caused by trapped air in the header of subcutaneous cardioverter‐defibrillator generator
In this study, we report two cases with oversensing due to air accumulation in the subcutaneous implantable cardioverter‐defibrillator (S‐ICD) device generator header. If trapped air in the header of the device is suspected, the re‐connection procedure should be considered or the primary vector must be used, which might prevent oversensing.
- Open Access
- 2 July 2023
- Published by Wiley in Journal of Arrhythmia
- Vol. 39 (4) , 627-629
Usefulness of “heart‐shaped sign” during “spaghetti twisting” technique in transvenous lead extraction
- 2 July 2023
- Published by Wiley in Journal of Arrhythmia
- Vol. 39 (4) , 627-629
Open AccessUsefulness of “heart‐shaped sign” during “spaghetti twisting” technique in transvenous lead extraction
- 1 August 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21527431,p. 2405-2410
Control of the wireless microrobot with multi-DOFs locomotion for medical applications
In this paper, we discuss a multi-DOFs locomotion and position detection system of the microrobot to realize the wireless locomotion. Also we propose one wireless microrobot with two motions controlled by changing the outside magnetic field. When generating alternating magnetic field, the microrobot can be driven by the fin motion just like fish. When generating rotating magnetic field, the microrobot can move in the spiral jet motion. Based on the experimental results of the locomotion, we confirm that the microrobot can move in forward, backward, floating motion and turning motion. In addition, we have developed a position detection system of the microrobot. We use least square method to solve the inverse problem. To evaluate the error of the proposed position detection system, we will do experiment by using 6 magnetic field sensors and program. Base on this experiment, we also confirm that the proposed position detection system can detect the position of the microrobot within 50mm from sensor in vertical direction, and its average error is within 6.09mm.
- 1 August 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21527431,p. 2405-2410
Control of the wireless microrobot with multi-DOFs locomotion for medical applications
In this paper, we discuss a multi-DOFs locomotion and position detection system of the microrobot to realize the wireless locomotion. Also we propose one wireless microrobot with two motions controlled by changing the outside magnetic field. When generating alternating magnetic field, the microrobot can be driven by the fin motion just like fish. When generating rotating magnetic field, the microrobot can move in the spiral jet motion. Based on the experimental results of the locomotion, we confirm that the microrobot can move in forward, backward, floating motion and turning motion. In addition, we have developed a position detection system of the microrobot. We use least square method to solve the inverse problem. To evaluate the error of the proposed position detection system, we will do experiment by using 6 magnetic field sensors and program. Base on this experiment, we also confirm that the proposed position detection system can detect the position of the microrobot within 50mm from sensor in vertical direction, and its average error is within 6.09mm.