Jae Yong Park
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jae Yong Park has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Dominik Todorov
Department of Medicine, Imperial College London, London SW7 2AZ, UK
2 shared publications Hayeon Lim
Faculty of Medicine, Imperial College London, London, UK
2 shared publications- Joon Ha
Department of Orthopaedics, King's College Hospital, London, UK
2 shared publications André Fernandes
Department of Trauma and Orthopaedics, York and Scarborough NHS Trust, London, UK
1 shared publicationAngelina Yoon
Faculty of Medicine, Monash University, Melbourne, Australia
1 shared publicationDushyanth Gnanappiragasam
Department of Dermatology, Imperial College Healthcare NHS Trust , London
1 shared publication
Latest Publications
- Open Access
- 20 January 2025
- Published by Oxford University Press (OUP) in Skin Health and Disease
- Vol. 5 (1) , 14-21
Assessing the readability of dermatological patient information leaflets generated by ChatGPT-4 and its associated plugins
Background: In the UK, 43% of adults struggle to understand health information presented in standard formats. As a result, Health Education England recommends that patient information leaflets (PILs) be written at a readability level appropriate for an 11-year-old. Objectives: To evaluate the ability of ChatGPT-4 and its three dermatology-specific plugins to generate PILs that meet readability recommendations and compare their readability with existing British Association of Dermatologists (BAD) PILs. Methods: ChatGPT-4 and its three plugins were used to generate PILs for 10 preselected dermatological conditions. The readability of these PILs was assessed using three readability formulas Simple Measure of Gobbledygook (SMOG), Flesch Reading Ease Test (FRET) and Flesch–Kincaid Grade Level Test (FKGLT) and compared against the readability of BAD PILs. A one-way ANOVA was conducted to identify any significant differences. Results: The readability scores of PILs generated by ChatGPT-4 and its plugins did not meet the recommended target range. However, some of these PILs demonstrated more favourable mean readability scores compared with those from the BAD, with certain plugins, such as Chat with a Dermatologist, showing significant differences in mean SMOG (P = 0.0005) and mean FKGLT (P = 0.002) scores. Nevertheless, the PILs generated by ChatGPT-4 were found to lack some of the content typically included in BAD PILs. Conclusions: ChatGPT-4 can produce dermatological PILs free from misleading information, occasionally surpassing BAD PILs in terms of readability. However, these PILs still fall short of being easily understood by the general public, and the content requires rigorous verification by healthcare professionals to ensure reliability and quality.
- 20 January 2025
- Published by Oxford University Press (OUP) in Skin Health and Disease
- Vol. 5 (1) , 14-21
Open AccessAssessing the readability of dermatological patient information leaflets generated by ChatGPT-4 and its associated plugins
Background: In the UK, 43% of adults struggle to understand health information presented in standard formats. As a result, Health Education England recommends that patient information leaflets (PILs) be written at a readability level appropriate for an 11-year-old. Objectives: To evaluate the ability of ChatGPT-4 and its three dermatology-specific plugins to generate PILs that meet readability recommendations and compare their readability with existing British Association of Dermatologists (BAD) PILs. Methods: ChatGPT-4 and its three plugins were used to generate PILs for 10 preselected dermatological conditions. The readability of these PILs was assessed using three readability formulas Simple Measure of Gobbledygook (SMOG), Flesch Reading Ease Test (FRET) and Flesch–Kincaid Grade Level Test (FKGLT) and compared against the readability of BAD PILs. A one-way ANOVA was conducted to identify any significant differences. Results: The readability scores of PILs generated by ChatGPT-4 and its plugins did not meet the recommended target range. However, some of these PILs demonstrated more favourable mean readability scores compared with those from the BAD, with certain plugins, such as Chat with a Dermatologist, showing significant differences in mean SMOG (P = 0.0005) and mean FKGLT (P = 0.002) scores. Nevertheless, the PILs generated by ChatGPT-4 were found to lack some of the content typically included in BAD PILs. Conclusions: ChatGPT-4 can produce dermatological PILs free from misleading information, occasionally surpassing BAD PILs in terms of readability. However, these PILs still fall short of being easily understood by the general public, and the content requires rigorous verification by healthcare professionals to ensure reliability and quality.
- Open Access
- 22 November 2024
- Published by Springer Nature in International Orthopaedics
- Vol. 49 (1) , 35-43
Biological augmentation of anterior cruciate ligament reconstruction with bone marrow aspirate concentrate: a systematic review and meta-analysis of randomised controlled trials
Purpose: Biological augmentation of anterior cruciate ligament (ACL) reconstruction with bone marrow aspirate concentrate (BMAC) is gaining attention for its theoretical potential to enhance postoperative healing and recovery. However, its clinical benefits remain uncertain, and its high cost raises questions about efficacy. Hence, we systematically reviewed randomised controlled trials (RCTs) to evaluate the effectiveness of BMAC in ACL reconstruction. Methods: Our search included Cochrane, EMBASE, OVID, PubMed, and Scopus databases for RCTs evaluating the use of BMAC in ACL reconstruction. Primary outcomes focused on International Knee Documentation Committee (IKDC) scores and Lysholm scores. Secondary outcomes included MRI-related outcomes and postoperative complications. Statistical analysis was conducted using Review Manager 5.4 (Cochrane Collaboration), with heterogeneity assessed using Cochrane’s Q test and I2 statistics. Results: 221 patients from five RCTs were included, with 109 (49.3%) receiving BMAC augmentation. Follow-up ranged from 11.05 to 24 months. No significant differences were found in postoperative IKDC scores between the BMAC and control groups at, three, six and 12 months. The BMAC group had significantly higher IKDC scores at 24 months; however, this difference was unlikely to be clinically significant. No significant differences were observed in postoperative Lysholm scores at 12 or 24 months. MRI-related outcomes suggested potential graft recovery improvement with BMAC, and complication rates were comparable between groups. Conclusion: In summary, biological augmentation with BMAC in ACL reconstruction does not significantly improve early patient-reported outcomes but offers potential benefits in graft recovery without increasing complication rates.
- 22 November 2024
- Published by Springer Nature in International Orthopaedics
- Vol. 49 (1) , 35-43
Open AccessBiological augmentation of anterior cruciate ligament reconstruction with bone marrow aspirate concentrate: a systematic review and meta-analysis of randomised controlled trials
Purpose: Biological augmentation of anterior cruciate ligament (ACL) reconstruction with bone marrow aspirate concentrate (BMAC) is gaining attention for its theoretical potential to enhance postoperative healing and recovery. However, its clinical benefits remain uncertain, and its high cost raises questions about efficacy. Hence, we systematically reviewed randomised controlled trials (RCTs) to evaluate the effectiveness of BMAC in ACL reconstruction. Methods: Our search included Cochrane, EMBASE, OVID, PubMed, and Scopus databases for RCTs evaluating the use of BMAC in ACL reconstruction. Primary outcomes focused on International Knee Documentation Committee (IKDC) scores and Lysholm scores. Secondary outcomes included MRI-related outcomes and postoperative complications. Statistical analysis was conducted using Review Manager 5.4 (Cochrane Collaboration), with heterogeneity assessed using Cochrane’s Q test and I2 statistics. Results: 221 patients from five RCTs were included, with 109 (49.3%) receiving BMAC augmentation. Follow-up ranged from 11.05 to 24 months. No significant differences were found in postoperative IKDC scores between the BMAC and control groups at, three, six and 12 months. The BMAC group had significantly higher IKDC scores at 24 months; however, this difference was unlikely to be clinically significant. No significant differences were observed in postoperative Lysholm scores at 12 or 24 months. MRI-related outcomes suggested potential graft recovery improvement with BMAC, and complication rates were comparable between groups. Conclusion: In summary, biological augmentation with BMAC in ACL reconstruction does not significantly improve early patient-reported outcomes but offers potential benefits in graft recovery without increasing complication rates.
- Open Access
- 16 May 2024
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 34 (5) , 2691-2699
Comparative effectiveness of peroneus longus tendon (PLT) autografts versus hamstring tendon (HT) autografts in anterior cruciate ligament reconstruction: a comprehensive systematic review and meta analysis
The hamstring tendon (HT) autograft is currently the most widely utilised autograft option for anterior cruciate ligament (ACL) reconstruction. However, recent studies endorse the peroneus longus tendon (PLT) autograft as a viable alternative. To evaluate this, we systematically reviewed randomised controlled trials (RCTs) to compare the efficacy of PLT against HT autografts. Our search encompassed Cochrane, Embase, OVID, PubMed, and Scopus databases for RCTs comparing outcomes of PLT and HT autografts in ACL reconstruction. Primary outcomes included Lysholm and International Knee Documentation Committee (IKDC) scores, while secondary outcomes involved American Orthopaedic Foot and Ankle Society (AOFAS) scores, graft diameters and donor-site complications. Statistical analysis was performed using Review Manager 5.4 (Cochrane Collaboration) and heterogeneity was assessed with I2 statistics. 683 patients from 6 RCTs were included, with 338 (49.5%) patients treated with PLT autografts. Follow-up ranged from 12 to 30 months. Despite lower preoperative Lysholm scores in the PLT group, no significant differences were observed at 6 and 12 months. Although preoperative and 6-month IKDC scores were lower in the PLT group, no significant differences were found at 12 and 24 months. AOFAS scores showed no significant preoperative difference, but slightly lower scores were noted in the PLT group at 12 or 24 months. There was no significant difference in graft diameter, while donor-site complications were fewer in the PLT group. In summary, the PLT autograft is a promising and non-inferior alternative to the HT autograft, demonstrating equivalent outcomes in patient-reported knee and ankle metrics, comparable graft diameters and fewer donor-site complications.
- 16 May 2024
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 34 (5) , 2691-2699
Open AccessComparative effectiveness of peroneus longus tendon (PLT) autografts versus hamstring tendon (HT) autografts in anterior cruciate ligament reconstruction: a comprehensive systematic review and meta analysis
The hamstring tendon (HT) autograft is currently the most widely utilised autograft option for anterior cruciate ligament (ACL) reconstruction. However, recent studies endorse the peroneus longus tendon (PLT) autograft as a viable alternative. To evaluate this, we systematically reviewed randomised controlled trials (RCTs) to compare the efficacy of PLT against HT autografts. Our search encompassed Cochrane, Embase, OVID, PubMed, and Scopus databases for RCTs comparing outcomes of PLT and HT autografts in ACL reconstruction. Primary outcomes included Lysholm and International Knee Documentation Committee (IKDC) scores, while secondary outcomes involved American Orthopaedic Foot and Ankle Society (AOFAS) scores, graft diameters and donor-site complications. Statistical analysis was performed using Review Manager 5.4 (Cochrane Collaboration) and heterogeneity was assessed with I2 statistics. 683 patients from 6 RCTs were included, with 338 (49.5%) patients treated with PLT autografts. Follow-up ranged from 12 to 30 months. Despite lower preoperative Lysholm scores in the PLT group, no significant differences were observed at 6 and 12 months. Although preoperative and 6-month IKDC scores were lower in the PLT group, no significant differences were found at 12 and 24 months. AOFAS scores showed no significant preoperative difference, but slightly lower scores were noted in the PLT group at 12 or 24 months. There was no significant difference in graft diameter, while donor-site complications were fewer in the PLT group. In summary, the PLT autograft is a promising and non-inferior alternative to the HT autograft, demonstrating equivalent outcomes in patient-reported knee and ankle metrics, comparable graft diameters and fewer donor-site complications.
- Open Access
- 8 February 2022
- Published by Springer Nature in Cureus
- Vol. 14 (2) , e22004
Visualising the Future of Orthopaedic Surgery: A Novel Application of Wireless Smart Glasses to Visualise Intraoperative Imaging
Smart glasses can provide a heads-up display of advanced imaging intraoperatively. In recent years, growing attention has been drawn to the use of smart glasses as an assistive technology to improve both efficiency and ergonomics in a surgical setting. Previous studies have reported improved surgical accuracy, efficiency, and ergonomics with its usage, but its effectiveness as a form of intraoperative heads-up display remains elusive in the context of orthopaedics. This study provides a novel account of a wireless set-up of the Moverio BT-35E Smart Glasses (Suwa, Japan: Epson Inc.), incorporated in a complex orthopaedic procedure. Hind-foot nailing was performed on a patient with a complex open ankle fracture and multiple co-morbidities. Smart glasses were worn by the primary surgeon throughout the procedure to provide heads-up visualisation of the intraoperative fluoroscopy. In our surgical case, the surgeon experienced improved ergonomics and reduced disruption to focus with the use of smart glasses. The wireless set-up provided excellent signal transmission throughout the duration of the procedure. The wireless set-up of smart glasses is a potential solution for common occupational risks imposed on orthopaedic surgeons. Smart glasses minimise musculoskeletal strain from switching of vision from monitor to patient, whilst the wireless set-up allows for efficient use of space in an operating theatre and may potentially limit radiation exposure. Lastly, ergonomic benefits may increase the efficiency of movement for the surgeon, decreasing operative duration, and in turn minimising the risk of surgical complications for patients.
- 8 February 2022
- Published by Springer Nature in Cureus
- Vol. 14 (2) , e22004
Open AccessVisualising the Future of Orthopaedic Surgery: A Novel Application of Wireless Smart Glasses to Visualise Intraoperative Imaging
Smart glasses can provide a heads-up display of advanced imaging intraoperatively. In recent years, growing attention has been drawn to the use of smart glasses as an assistive technology to improve both efficiency and ergonomics in a surgical setting. Previous studies have reported improved surgical accuracy, efficiency, and ergonomics with its usage, but its effectiveness as a form of intraoperative heads-up display remains elusive in the context of orthopaedics. This study provides a novel account of a wireless set-up of the Moverio BT-35E Smart Glasses (Suwa, Japan: Epson Inc.), incorporated in a complex orthopaedic procedure. Hind-foot nailing was performed on a patient with a complex open ankle fracture and multiple co-morbidities. Smart glasses were worn by the primary surgeon throughout the procedure to provide heads-up visualisation of the intraoperative fluoroscopy. In our surgical case, the surgeon experienced improved ergonomics and reduced disruption to focus with the use of smart glasses. The wireless set-up provided excellent signal transmission throughout the duration of the procedure. The wireless set-up of smart glasses is a potential solution for common occupational risks imposed on orthopaedic surgeons. Smart glasses minimise musculoskeletal strain from switching of vision from monitor to patient, whilst the wireless set-up allows for efficient use of space in an operating theatre and may potentially limit radiation exposure. Lastly, ergonomic benefits may increase the efficiency of movement for the surgeon, decreasing operative duration, and in turn minimising the risk of surgical complications for patients.