Malia Ho
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Malia Ho has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Pui Wah Kong
Nanyang Technological University
3 shared publications - Crystal O. Kean
Discipline of Sport and Exercise Science, Faculty of Health, University of Canberra, Canberra, ACT, Australia
2 shared publications - Julie Nguyen
Department of Podiatry, School of Health, Medical and Applied Sciences, CQUniversity Australia, Building 34, Bruce Highway, North Rockhampton, QLD 4701, Australia
2 shared publications - Luke James Heales
Central Queensland University
2 shared publications - Robert Stanton
School of Medical and Applied Sciences, Central Queensland University, Rockhampton, Queensland, Australia
2 shared publications Adriaan Erasmus
Liverpool Hospital
1 shared publication
Latest Publications
- Open Access
- 17 November 2025
- Published by Bond University in Australian Journal of Clinical Education
- Vol. 14 (1) , 117-133
Using a Novel 3D-Printed Foot Model in Simulation-Based Learning of Podiatry Clinical Skills: A Qualitative Study on Students’ Learning Experience
Background Undergraduate Podiatry students are expected to perform clinical skills such as sharp debridement safely and competently before graduating. Simulation-based education is a way to provide authentic learning. The aim of this study was to evaluate the student learning experience using a low-cost purpose-designed 3D-printed foot model compared to a commercially available foot model in novice learners. Methods Students with no prior training to scalpel skills were recruited. Participants were provided with a 30-minute debridement skill training, following which they practiced on 1) novel 3D-printed foot model, and 2) commercial foot model. Participants provided qualitative feedback via an anonymous questionnaire. Results Ten students participated in this study. Four themes were identified relating to 1) positive learning experience; 2) confidence level; 3) safety and ease of use; and 4) quality of the foot models. Participants felt that using the 3D-printed foot model provided a superior learning experience to the commercial foot model, with more practice time resulting in increased confidence. Regarding the safety and ease of use, the 3D-printed foot model was easier to manoeuvre into various positions. Conclusions The novel 3D-printed foot model improved learning experience compared to a commercially available foot model. Further improvements have been identified, and its use can be considered in podiatry skills training.
- 17 November 2025
- Published by Bond University in Australian Journal of Clinical Education
- Vol. 14 (1) , 117-133
Open AccessUsing a Novel 3D-Printed Foot Model in Simulation-Based Learning of Podiatry Clinical Skills: A Qualitative Study on Students’ Learning Experience
Background Undergraduate Podiatry students are expected to perform clinical skills such as sharp debridement safely and competently before graduating. Simulation-based education is a way to provide authentic learning. The aim of this study was to evaluate the student learning experience using a low-cost purpose-designed 3D-printed foot model compared to a commercially available foot model in novice learners. Methods Students with no prior training to scalpel skills were recruited. Participants were provided with a 30-minute debridement skill training, following which they practiced on 1) novel 3D-printed foot model, and 2) commercial foot model. Participants provided qualitative feedback via an anonymous questionnaire. Results Ten students participated in this study. Four themes were identified relating to 1) positive learning experience; 2) confidence level; 3) safety and ease of use; and 4) quality of the foot models. Participants felt that using the 3D-printed foot model provided a superior learning experience to the commercial foot model, with more practice time resulting in increased confidence. Regarding the safety and ease of use, the 3D-printed foot model was easier to manoeuvre into various positions. Conclusions The novel 3D-printed foot model improved learning experience compared to a commercially available foot model. Further improvements have been identified, and its use can be considered in podiatry skills training.
- Open Access
- 12 December 2023
- Published by Taylor & Francis in Disability and Rehabilitation
- Vol. 46 (20) , 4779-4786
Practitioners preference in using electrotherapy to treat paediatric lower limb conditions: an online survey
Electrotherapies are commonly used to treat adult musculoskeletal pathologies. However, there is insufficient evidence supporting the use of electrotherapies for lower limb conditions in children. Currently, it is unknown how electrotherapies are used in paediatric clinical practice. This study aimed to investigate if practitioners use electrotherapy to treat children's lower limb conditions, frequency and why. A custom-built online survey was disseminated via social media targeting international medical and healthcare practitioners who treat children with lower limb conditions using electrotherapy. Practitioners were asked if they did or did not use electrotherapies, and their reasons. Responses were described in frequencies and with thematic analysis. There were 445 practitioners who responded. From these, 301(68%) indicated they used electrotherapy, with the most frequently used being Transcutaneous Electrical Nerve Stimulation (n = 110). The most common reason cited for using electrotherapy was practitioner preference due to the alleged effectiveness of the chosen modality. The remaining 144 (32%) practitioners reported not using electrotherapy, the most common reason being lack of evidence. We found that a majority of practitioners used electrotherapies on children. The reasons for using or not using electrotherapy were practitioner centred.
- 12 December 2023
- Published by Taylor & Francis in Disability and Rehabilitation
- Vol. 46 (20) , 4779-4786
Open AccessPractitioners preference in using electrotherapy to treat paediatric lower limb conditions: an online survey
Electrotherapies are commonly used to treat adult musculoskeletal pathologies. However, there is insufficient evidence supporting the use of electrotherapies for lower limb conditions in children. Currently, it is unknown how electrotherapies are used in paediatric clinical practice. This study aimed to investigate if practitioners use electrotherapy to treat children's lower limb conditions, frequency and why. A custom-built online survey was disseminated via social media targeting international medical and healthcare practitioners who treat children with lower limb conditions using electrotherapy. Practitioners were asked if they did or did not use electrotherapies, and their reasons. Responses were described in frequencies and with thematic analysis. There were 445 practitioners who responded. From these, 301(68%) indicated they used electrotherapy, with the most frequently used being Transcutaneous Electrical Nerve Stimulation (n = 110). The most common reason cited for using electrotherapy was practitioner preference due to the alleged effectiveness of the chosen modality. The remaining 144 (32%) practitioners reported not using electrotherapy, the most common reason being lack of evidence. We found that a majority of practitioners used electrotherapies on children. The reasons for using or not using electrotherapy were practitioner centred.
- Open Access
- 3 July 2023
- Published by Taylor & Francis in Footwear Science
- Vol. 15 (3) , 179-184
The effectiveness of heel raises in managing Haglund deformity pain in figure skaters – a pilot study
- 3 July 2023
- Published by Taylor & Francis in Footwear Science
- Vol. 15 (3) , 179-184
Open AccessThe effectiveness of heel raises in managing Haglund deformity pain in figure skaters – a pilot study
- Open Access
- 11 June 2022
- Published by Elsevier in Gait & Posture
- Vol. 96, 257-264
The biomechanical effects of 3D printed and traditionally made foot orthoses in individuals with unilateral plantar fasciopathy and flat feet
- 11 June 2022
- Published by Elsevier in Gait & Posture
- Vol. 96, 257-264
Open AccessThe biomechanical effects of 3D printed and traditionally made foot orthoses in individuals with unilateral plantar fasciopathy and flat feet
- Open Access
- 22 November 2021
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
- Vol. 46 (1) , 31-36
Immediate comfort perception of 3D-printed foot orthoses in individuals with unilateral heel pain
Background: Custom-made foot orthoses (FOs) play an integral part in managing foot disorders. Traditional FO fabrication is time-consuming and labor intensive. Three-dimensional (3D) printed FOs save time and cost compared with the traditional manufacturing process. To date, the differences in dimensions and comfort perception of these orthoses have not been compared in a pathological population. Objective: Compare the dimensions between 3D-printed and traditionally made FOs and comfort perception between 3D-printed, traditionally made, and no FOs in individuals with flatfeet and unilateral heel pain. Study design: Within-subject single-blinded randomized crossover study design. Methods: Thirteen participants had custom-made FOs using 3D-printing and traditional processes. Orthotic lengths, widths, arch heights, and heel cup heights were compared. Participants performed walking trials under three conditions: (1) no orthoses, (2) 3D-printed orthoses, and (3) traditionally made orthoses. Comfort perception was recorded. Orthotic dimensions were compared using paired t tests, and comfort perception were compared using one-way multiple analysis of variance and Bonferroni post hoc tests. Results: Three-dimensional–printed orthoses were wider, have higher arch heights, and heel cup heights compared with traditionally made FOs (medium to large effect sizes). There was a difference in comfort perception between the three orthotic conditions, F(12,62) = 1.99, P = 0.04; Wilk Λ = 0.521, η p 2 = 0.279. Post hoc tests show that there is no difference in comfort perception between the 3D-printed and traditionally made FOs. Both FOs were significantly more comfortable than no orthoses. Conclusions: Three-dimensional printing seems to be a viable alternative orthotic fabrication option. Future studies should compare the biomechanical effects of 3D-printed and traditionally made FOs.
- 22 November 2021
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
- Vol. 46 (1) , 31-36
Open AccessImmediate comfort perception of 3D-printed foot orthoses in individuals with unilateral heel pain
Background: Custom-made foot orthoses (FOs) play an integral part in managing foot disorders. Traditional FO fabrication is time-consuming and labor intensive. Three-dimensional (3D) printed FOs save time and cost compared with the traditional manufacturing process. To date, the differences in dimensions and comfort perception of these orthoses have not been compared in a pathological population. Objective: Compare the dimensions between 3D-printed and traditionally made FOs and comfort perception between 3D-printed, traditionally made, and no FOs in individuals with flatfeet and unilateral heel pain. Study design: Within-subject single-blinded randomized crossover study design. Methods: Thirteen participants had custom-made FOs using 3D-printing and traditional processes. Orthotic lengths, widths, arch heights, and heel cup heights were compared. Participants performed walking trials under three conditions: (1) no orthoses, (2) 3D-printed orthoses, and (3) traditionally made orthoses. Comfort perception was recorded. Orthotic dimensions were compared using paired t tests, and comfort perception were compared using one-way multiple analysis of variance and Bonferroni post hoc tests. Results: Three-dimensional–printed orthoses were wider, have higher arch heights, and heel cup heights compared with traditionally made FOs (medium to large effect sizes). There was a difference in comfort perception between the three orthotic conditions, F(12,62) = 1.99, P = 0.04; Wilk Λ = 0.521, η p 2 = 0.279. Post hoc tests show that there is no difference in comfort perception between the 3D-printed and traditionally made FOs. Both FOs were significantly more comfortable than no orthoses. Conclusions: Three-dimensional printing seems to be a viable alternative orthotic fabrication option. Future studies should compare the biomechanical effects of 3D-printed and traditionally made FOs.
- Open Access
- 1 January 2019
- Published by Wiley in Journal of Foot and Ankle Research
- Vol. 12 (1) , 24
Foot orthoses alter lower limb biomechanics but not jump performance in basketball players with and without flat feet
Background: Flat‐footed individuals are believed to have poorer jump performance compared to normal‐arched individuals. Foot orthoses are commonly used to support the deformed foot arch, and improve normal foot function. However, it is unclear if foot orthoses use affects jump performance in athletes. Our study aims to investigate if foot type and/or foot orthosis influence countermovement jump (CMJ) and standing broad jump (SBJ) performance and lower limb biomechanics.Methods: Twenty‐six male basketball players were classified into normal‐arched (n = 15) or flat‐footed (n = 11) groups using the Chippaux‐Smirak index, navicular drop test, and the resting calcaneal angle measurement. They performed jumps with and without prefabricated foot orthoses. We measured jump height and distance for CMJ and SBJ, respectively. Hip, knee and ankle joint angles, angular velocities, moments and powers during take‐off were also measured.Results: For CMJ, the flat‐footed group exhibited less ankle plantarflexion (F1,24 = 8.407, p = 0.008, ηp2 = 0.259 large effect) and less hip joint power (F1,24 = 7.416, p = 0.012, ηp2 = 0.244 large effect) than the normal‐arched group. Foot orthoses reduced ankle eversion in both groups (F1,24 = 6.702, p = 0.016, ηp2 = 0.218 large effect). For SBJ, the flat‐footed group produced lower peak hip angular velocity (F1,24 = 7.115, p = 0.013, ηp2 = 0.229 large effect) and generated lower horizontal GRF (F1,24 = 5.594, p = 0.026, ηp2 = 0.189 large effect) than the normal‐arched group. Wearing foot orthoses reduced ankle eversion (F1,24 = 5.453, p = 0.028, ηp2 = 0.185 large effect), peak horizontal GRF (F1,24 = 13.672, p = 0.001, ηp2 = 0.363 large effect) and frontal plane ankle moment (F1,24 = 4.932, p = 0.036, ηp2 = 0.170 large effect).Conclusion: Foot type and the use of foot orthoses influence take‐off biomechanics, but not actual CMJ and SBJ performances in basketball players. Compared to the normal‐arched individuals, flat‐footed athletes generated smaller propulsion GRF and lower hip flexion velocity and power, which suggests possible compensatory movement strategies to maximise jump performance. Future studies may investigate whether these altered biomechanics, taking into consideration their respective magnitude and effect sizes, may have implications on lower limb injuries. The use of foot orthoses resulted in biomechanical changes in both the normal‐arched and flat‐footed groups but does not enhance jumping performance.
- 1 January 2019
- Published by Wiley in Journal of Foot and Ankle Research
- Vol. 12 (1) , 24
Open AccessFoot orthoses alter lower limb biomechanics but not jump performance in basketball players with and without flat feet
Background: Flat‐footed individuals are believed to have poorer jump performance compared to normal‐arched individuals. Foot orthoses are commonly used to support the deformed foot arch, and improve normal foot function. However, it is unclear if foot orthoses use affects jump performance in athletes. Our study aims to investigate if foot type and/or foot orthosis influence countermovement jump (CMJ) and standing broad jump (SBJ) performance and lower limb biomechanics.Methods: Twenty‐six male basketball players were classified into normal‐arched (n = 15) or flat‐footed (n = 11) groups using the Chippaux‐Smirak index, navicular drop test, and the resting calcaneal angle measurement. They performed jumps with and without prefabricated foot orthoses. We measured jump height and distance for CMJ and SBJ, respectively. Hip, knee and ankle joint angles, angular velocities, moments and powers during take‐off were also measured.Results: For CMJ, the flat‐footed group exhibited less ankle plantarflexion (F1,24 = 8.407, p = 0.008, ηp2 = 0.259 large effect) and less hip joint power (F1,24 = 7.416, p = 0.012, ηp2 = 0.244 large effect) than the normal‐arched group. Foot orthoses reduced ankle eversion in both groups (F1,24 = 6.702, p = 0.016, ηp2 = 0.218 large effect). For SBJ, the flat‐footed group produced lower peak hip angular velocity (F1,24 = 7.115, p = 0.013, ηp2 = 0.229 large effect) and generated lower horizontal GRF (F1,24 = 5.594, p = 0.026, ηp2 = 0.189 large effect) than the normal‐arched group. Wearing foot orthoses reduced ankle eversion (F1,24 = 5.453, p = 0.028, ηp2 = 0.185 large effect), peak horizontal GRF (F1,24 = 13.672, p = 0.001, ηp2 = 0.363 large effect) and frontal plane ankle moment (F1,24 = 4.932, p = 0.036, ηp2 = 0.170 large effect).Conclusion: Foot type and the use of foot orthoses influence take‐off biomechanics, but not actual CMJ and SBJ performances in basketball players. Compared to the normal‐arched individuals, flat‐footed athletes generated smaller propulsion GRF and lower hip flexion velocity and power, which suggests possible compensatory movement strategies to maximise jump performance. Future studies may investigate whether these altered biomechanics, taking into consideration their respective magnitude and effect sizes, may have implications on lower limb injuries. The use of foot orthoses resulted in biomechanical changes in both the normal‐arched and flat‐footed groups but does not enhance jumping performance.