ENEvan C. Norris

Evan C. Norris

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Evan C. Norris has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Efficacy of Whole‐Blood Model of Gadolinium‐Based Contrast Agent Relaxivity in Predicting Vascular MR Signal Intensity In Vivo

    by Evan C. Norris, Guenther Schneider, Toshimasa J. Clark, Miles A. Kirchin, Gregory J. Wilson, Jeffrey H. Maki

    Background: Previous in vitro studies have described sub‐linear longitudinal and heightened transverse H2O relaxivities of gadolinium‐based contrast agents (GBCAs) in blood due to their extracellular nature. However, in vivo validation is lacking.Purpose: Validate theory describing blood behavior of R1 and R2* in an animal model.Study Type: Prospective, animal.Animal Model: Seven swine (54–65 kg).Field Strength/Sequence: 1.5 T; time‐resolved 3D spoiled gradient‐recalled echo (SPGR) and quantitative Look‐Locker and multi‐echo fast field echo sequences.Assessment: Seven swine were each injected three times with 0.1 mmol/kg intravenous doses of one of three GBCAs: gadoteridol, gadobutrol, and gadobenate dimeglumine. Injections were randomized for rate (1, 2, and 3 mL/s) and order, during which time‐resolved aortic 3D SPGR imaging was performed concurrently with aortic blood sampling via an indwelling catheter. Time‐varying [GBCA] was measured by mass spectrometry of sampled blood. Predicted signal intensity (SI) was determined from a model incorporating sub‐linear R1 and R2* effects (whole‐blood model) and simpler models incorporating linear R1, with and without R2* effects. Predicted SIs were compared to measured aortic SI.Statistical Tests: Linear correlation (coefficient of determination, R2) and mean errors were compared across the SI prediction models.Results: There was an excellent correlation between predicted and measured SI across all injections and swine when accounting for the non‐linear dependence of R1 and high blood R2* (regression slopes 0.91–1.04, R2 ≥ 0.91). Simplified models (linear R1 with and without R2* effects) showed poorer correlation (slopes 0.67–0.85 and 0.54–0.64 respectively, both R2 ≥ 0.89) and higher averaged mean absolute and mean square errors (128.4 and 177.4 vs. 42.0, respectively, and 5506 and 11,419 vs. 699, respectively).Data Conclusion: Incorporating sub‐linear R1 and high first‐pass R2* effects in arterial blood models allows accurate SPGR SI prediction in an in vivo animal model, and might be utilized when modeling MR blood SI.Level of Evidence: 1Technical Efficacy: Stage 1


  • Open Access

    Understanding Patient Experiences, Opinions, and Actions Taken After Viewing Their Own Radiology Images Online: Web-Based Survey

    by Evan C Norris, Ciarra Halaska, Peter B Sachs, Chen-Tan Lin, Kate Sanfilippo, Justin M Honce

    Background: The ability for patients to directly view their radiology images through secure electronic portals is rare in the American health care system. We previously surveyed patients within our health system and found that a large majority wanted to view their own radiology images online, and we have since implemented this new feature. Objective: We aim to understand patient experiences, opinions, and actions taken after viewing their own radiology images online. Methods: We emailed a web-based survey to patients who recently viewed their radiology images via our electronic patient portal. Results: We sent 1825 surveys to patients and received 299 responses (response rate 16.4%). Patients reported a favorable experience (258/299, 86.3% agree) viewing their radiology images online. Patients found value in reading their radiology reports (288/299, 96.3% agree) and viewing their images (267/299, 89.3% agree). Overall, patients felt that accessing and viewing their radiology images online increased their understanding of their medical condition (258/299, 82.9%), made them feel more in control and reassured (237/299, 79.2% and 220/299, 73.6%, respectively), and increased levels of trust (214/299, 71.6%). Only 6.4% (19/299) of the patients indicated concerns with finding errors, 6.4% (19/299) felt that viewing their images online made them worry more, and 7% (21/299) felt confused when viewing their images online. Of patients who viewed their images online, 45.2% (135/299) took no action with their images, 32.8% (98/299) saved a copy for their records, 25.4% (76/299) shared them with their doctor, and 14.7% (44/299) shared them with another doctor for a second opinion. A total of 9 patients (3%) shared their radiology images on Facebook, Instagram, or both, primarily to inform family and friends. Approximately 10.4% (31/299) of the patients had questions about their radiology images after viewing them online, with the majority (20/31, 65%) seeking out a doctor, and far fewer (5/31, 16%) choosing to ask a family member about their images. Finally, respondents viewed their images online using 1 or more devices, including computers, smartphones, tablets, or a combination of these devices. Approximately 26.7% (103/385) of the responses noted technical difficulties, with the highest incidence rate occurring with smartphones. Conclusions: We report the first known survey results from patients who viewed their own radiology images through a web-based portal. Patients reported high levels of satisfaction and increased levels of trust, autonomy, reassurance, and medical understanding. Only a small minority of patients expressed anxiety or confusion. We suggest that patient access to radiology images, such as patient access to radiology reports, is highly desired by patients and is operationally practical. Other health care institutions should consider offering patients access to their radiology images online in the pursuit of information transparency.


  • Open Access

    Understanding Patient Experiences, Opinions, and Actions Taken After Viewing Their Own Radiology Images Online: Web-Based Survey (Preprint)

    by Evan C Norris, Ciarra Halaska, Peter B Sachs, Chen-Tan Lin, Kate Sanfilippo, Justin M Honce

    BACKGROUND The ability for patients to directly view their radiology images through secure electronic portals is rare in the American health care system. We previously surveyed patients within our health system and found that a large majority wanted to view their own radiology images online, and we have since implemented this new feature. OBJECTIVE We aim to understand patient experiences, opinions, and actions taken after viewing their own radiology images online. METHODS We emailed a web-based survey to patients who recently viewed their radiology images via our electronic patient portal. RESULTS We sent 1825 surveys to patients and received 299 responses (response rate 16.4%). Patients reported a favorable experience (258/299, 86.3% agree) viewing their radiology images online. Patients found value in reading their radiology reports (288/299, 96.3% agree) and viewing their images (267/299, 89.3% agree). Overall, patients felt that accessing and viewing their radiology images online increased their understanding of their medical condition (258/299, 82.9%), made them feel more in control and reassured (237/299, 79.2% and 220/299, 73.6%, respectively), and increased levels of trust (214/299, 71.6%). Only 6.4% (19/299) of the patients indicated concerns with finding errors, 6.4% (19/299) felt that viewing their images online made them worry more, and 7% (21/299) felt confused when viewing their images online. Of patients who viewed their images online, 45.2% (135/299) took no action with their images, 32.8% (98/299) saved a copy for their records, 25.4% (76/299) shared them with their doctor, and 14.7% (44/299) shared them with another doctor for a second opinion. A total of 9 patients (3%) shared their radiology images on Facebook, Instagram, or both, primarily to inform family and friends. Approximately 10.4% (31/299) of the patients had questions about their radiology images after viewing them online, with the majority (20/31, 65%) seeking out a doctor, and far fewer (5/31, 16%) choosing to ask a family member about their images. Finally, respondents viewed their images online using 1 or more devices, including computers, smartphones, tablets, or a combination of these devices. Approximately 26.7% (103/385) of the responses noted technical difficulties, with the highest incidence rate occurring with smartphones. CONCLUSIONS We report the first known survey results from patients who viewed their own radiology images through a web-based portal. Patients reported high levels of satisfaction and increased levels of trust, autonomy, reassurance, and medical understanding. Only a small minority of patients expressed anxiety or confusion. We suggest that patient access to radiology images, such as patient access to radiology reports, is highly desired by patients and is operationally practical. Other health care institutions should consider offering patients access to their radiology images online in the pursuit of information transparency.