Anand Parekh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Anand Parekh has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Joyce S. Plested
Clinical Immunology, Novavax, Gaithersburg, MD 20878, USA
4 shared publications - Mingzhu Zhu
Clinical Immunology, Novavax, Gaithersburg, MD 20878, USA
4 shared publications - Raj Kalkeri
Clinical Immunology, Novavax, Gaithersburg, MD 20878, USA
4 shared publications - Rongman Cai
Biostatistics, Novavax, Gaithersburg, MD 20878, USA
4 shared publications - Shane Cloney-Clark
Clinical Immunology, Novavax, Gaithersburg, MD 20878, USA
4 shared publications - David Silva
Clinical Immunology, Novavax, Gaithersburg, MD 20878, USA
3 shared publications
Latest Publications
- Open Access
- 20 May 2026
- Published by MDPI AG in Microorganisms
- Vol. 14 (5) , 1154
Validation of a Mucosal IgA Assay for SARS-CoV-2
Mucosal immunity, including antibodies like immunoglobulin A (IgA), function as the body’s first line of defense in the respiratory tract, particularly against viruses. An anti-rS protein IgA enzyme-linked immunosorbent assay (ELISA) was developed using the Omicron XBB.1.5 subvariant of SARS-CoV-2 and was validated to demonstrate the suitability of the method for testing saliva from SARS-CoV-2 vaccine clinical trials. This assay successfully met acceptance criteria for inter-/intra-assay precision, specificity, selectivity, linearity, lower/upper limits of quantitation, and assay robustness. The IgA in saliva was stable for up to 7 freeze/thaw cycles, for up to 48 h at 24 °C, up to 7 days at 4 °C, up to 3 weeks at −20 °C, and up to 1 year at −80 °C. After validation using Omicron XBB.1.5 rS protein, cross-reactivity was demonstrated with the SARS-CoV-2 variant JN.1. This validated IgA assay can be a valuable tool to assess mucosal IgA levels in SARS-CoV-2 clinical trials.
- 20 May 2026
- Published by MDPI AG in Microorganisms
- Vol. 14 (5) , 1154
Open AccessValidation of a Mucosal IgA Assay for SARS-CoV-2
Mucosal immunity, including antibodies like immunoglobulin A (IgA), function as the body’s first line of defense in the respiratory tract, particularly against viruses. An anti-rS protein IgA enzyme-linked immunosorbent assay (ELISA) was developed using the Omicron XBB.1.5 subvariant of SARS-CoV-2 and was validated to demonstrate the suitability of the method for testing saliva from SARS-CoV-2 vaccine clinical trials. This assay successfully met acceptance criteria for inter-/intra-assay precision, specificity, selectivity, linearity, lower/upper limits of quantitation, and assay robustness. The IgA in saliva was stable for up to 7 freeze/thaw cycles, for up to 48 h at 24 °C, up to 7 days at 4 °C, up to 3 weeks at −20 °C, and up to 1 year at −80 °C. After validation using Omicron XBB.1.5 rS protein, cross-reactivity was demonstrated with the SARS-CoV-2 variant JN.1. This validated IgA assay can be a valuable tool to assess mucosal IgA levels in SARS-CoV-2 clinical trials.
- Open Access
- 19 November 2024
- Published by MDPI AG in Microorganisms
- Vol. 12 (11) , 2358
A Modified Novel Validated High-Throughput Hemagglutinin Inhibition Assay Using Recombinant Virus-like Particles and Human Red Blood Cells for the Objective Evaluation of Recombinant Hemagglutinin Nanoparticle Seasonal Influenza Vaccine
Currently available seasonal influenza vaccines confer variable protection due to antigenic changes resulting from the accumulation of diverse mutations. The analysis of new seasonal influenza vaccines is challenging in part due to the limitations of the traditional hemagglutination inhibition (HAI) assay with A/H3N2 strains. An improved and objective novel HAI assay was developed with recombinant virus-like particles (VLPs) and an egg-derived virus as agglutinins, the oseltamivir treatment of VLPs, human red blood cells, and using an automated image reader-based analysis of hemagglutination. HAI validation was demonstrated using four VLPs and egg-derived strains, with 46–56 serum samples tested 12 times in duplicate per strain. The validated HAI assay was precise as indicated by the percent geometric coefficient of variation for intra-, inter-, and total assay precision, as well as accurate as evidenced by percent bias measurements. The assay exhibited linearity, specificity for homologous type/subtype strains, and sensitivity with a starting dilution of 1:10. Assay robustness and sample stability were demonstrated as a percentage difference compared to reference condition. Validated HAI results were equivalent for the single and duplicate sample testing and correlated well with a qualified live wild-type influenza microneutralization assay. These findings demonstrate the suitability of this high-throughput novel modified validated HAI assay for evaluating vaccine immunogenicity and efficacy.
- 19 November 2024
- Published by MDPI AG in Microorganisms
- Vol. 12 (11) , 2358
Open AccessA Modified Novel Validated High-Throughput Hemagglutinin Inhibition Assay Using Recombinant Virus-like Particles and Human Red Blood Cells for the Objective Evaluation of Recombinant Hemagglutinin Nanoparticle Seasonal Influenza Vaccine
Currently available seasonal influenza vaccines confer variable protection due to antigenic changes resulting from the accumulation of diverse mutations. The analysis of new seasonal influenza vaccines is challenging in part due to the limitations of the traditional hemagglutination inhibition (HAI) assay with A/H3N2 strains. An improved and objective novel HAI assay was developed with recombinant virus-like particles (VLPs) and an egg-derived virus as agglutinins, the oseltamivir treatment of VLPs, human red blood cells, and using an automated image reader-based analysis of hemagglutination. HAI validation was demonstrated using four VLPs and egg-derived strains, with 46–56 serum samples tested 12 times in duplicate per strain. The validated HAI assay was precise as indicated by the percent geometric coefficient of variation for intra-, inter-, and total assay precision, as well as accurate as evidenced by percent bias measurements. The assay exhibited linearity, specificity for homologous type/subtype strains, and sensitivity with a starting dilution of 1:10. Assay robustness and sample stability were demonstrated as a percentage difference compared to reference condition. Validated HAI results were equivalent for the single and duplicate sample testing and correlated well with a qualified live wild-type influenza microneutralization assay. These findings demonstrate the suitability of this high-throughput novel modified validated HAI assay for evaluating vaccine immunogenicity and efficacy.
- Open Access
- 11 October 2024
- Published by MDPI AG in Preprints.org
A Modified Novel Validated High-Throughput Hemagglutinin Inhibition Assay Using Recombinant Virus-Like Particles and Human Red Blood Cells for the Objective Evaluation of Recombinant Hemagglutinin Nanoparticle Seasonal Influenza Vaccine
Currently available seasonal influenza vaccines confer variable protection due to antigenic changes resulting from accumulation of diverse mutations. Analysis of new seasonal influenza vaccines is challenging in part due to limitations of the traditional hemagglutination inhibition (HAI) assay with A/H3N2 strains. An improved and objective novel HAI assay was developed using recombinant virus-like particles (VLPs) and egg-derived virus as agglutinins, oseltamivir treatment of VLPs, human red blood cells, and using an automated image reader-based analysis of hemagglutination. HAI validation was demonstrated using four VLP and egg-derived strains, with 46–56 serum samples tested 12 times in duplicate per strain. The validated HAI assay was precise as indicated by the percent geometric coefficient of variation for intra-, inter-, and total-assay precision, and accurate as evidenced by % bias measurements. The assay exhibited linearity, specificity for homologous type/subtype strains, and sensitivity with a starting dilution of 1:10. Assay robustness and sample stability were demonstrated as a % difference compared to reference condition. Validated HAI results were equivalent for singleton and duplicate sample testing and correlated well with a qualified live wild-type influenza microneutralization assay. These findings demonstrate the suitability of this high-throughput novel modified validated HAI assay, for evaluating vaccine immunogenicity and efficacy.
- 11 October 2024
- Published by MDPI AG in Preprints.org
Open AccessA Modified Novel Validated High-Throughput Hemagglutinin Inhibition Assay Using Recombinant Virus-Like Particles and Human Red Blood Cells for the Objective Evaluation of Recombinant Hemagglutinin Nanoparticle Seasonal Influenza Vaccine
Currently available seasonal influenza vaccines confer variable protection due to antigenic changes resulting from accumulation of diverse mutations. Analysis of new seasonal influenza vaccines is challenging in part due to limitations of the traditional hemagglutination inhibition (HAI) assay with A/H3N2 strains. An improved and objective novel HAI assay was developed using recombinant virus-like particles (VLPs) and egg-derived virus as agglutinins, oseltamivir treatment of VLPs, human red blood cells, and using an automated image reader-based analysis of hemagglutination. HAI validation was demonstrated using four VLP and egg-derived strains, with 46–56 serum samples tested 12 times in duplicate per strain. The validated HAI assay was precise as indicated by the percent geometric coefficient of variation for intra-, inter-, and total-assay precision, and accurate as evidenced by % bias measurements. The assay exhibited linearity, specificity for homologous type/subtype strains, and sensitivity with a starting dilution of 1:10. Assay robustness and sample stability were demonstrated as a % difference compared to reference condition. Validated HAI results were equivalent for singleton and duplicate sample testing and correlated well with a qualified live wild-type influenza microneutralization assay. These findings demonstrate the suitability of this high-throughput novel modified validated HAI assay, for evaluating vaccine immunogenicity and efficacy.
- Open Access
- 11 July 2023
- Published by MDPI AG in Microorganisms
- Vol. 11 (7) , 1789
A Severe Acute Respiratory Syndrome Coronavirus 2 Anti-Spike Immunoglobulin G Assay: A Robust Method for Evaluation of Vaccine Immunogenicity Using an Established Correlate of Protection
As the COVID-19 pandemic continues, variants of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) continue to emerge. Immunogenicity evaluation of vaccines and identification of correlates of protection for vaccine effectiveness is critical to aid the development of vaccines against emerging variants. Anti-recombinant spike (rS) protein immunoglobulin G (IgG) quantitation in the systemic circulation (serum/plasma) is shown to correlate with vaccine efficacy. Thus, an enzyme-linked immunosorbent assay (ELISA)-based binding assay to detect SARS-CoV-2 (ancestral and variant strains) anti-rS IgG in human serum samples was developed and validated. This assay successfully met acceptance criteria for inter/intra-assay precision, specificity, selectivity, linearity, lower/upper limits of quantitation, matrix effects, and assay robustness. The analyte in serum was stable for up to 8 freeze/thaw cycles and 2 years in −80 °C storage. Similar results were observed for the Beta, Delta, and Omicron BA.1/BA.5/XBB.1.5 variant-adapted assays. Anti-rS IgG assay results correlated significantly with neutralization and receptor binding inhibition assays. In addition, usage of international reference standards allows data extrapolation to WHO international units (BAU/mL), facilitating comparison of results with other IgG assays. This anti-rS IgG assay is a robust, high-throughput method to evaluate binding IgG responses to S protein in serum, enabling rapid development of effective vaccines against emerging COVID-19 variants.
- 11 July 2023
- Published by MDPI AG in Microorganisms
- Vol. 11 (7) , 1789
Open AccessA Severe Acute Respiratory Syndrome Coronavirus 2 Anti-Spike Immunoglobulin G Assay: A Robust Method for Evaluation of Vaccine Immunogenicity Using an Established Correlate of Protection
As the COVID-19 pandemic continues, variants of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) continue to emerge. Immunogenicity evaluation of vaccines and identification of correlates of protection for vaccine effectiveness is critical to aid the development of vaccines against emerging variants. Anti-recombinant spike (rS) protein immunoglobulin G (IgG) quantitation in the systemic circulation (serum/plasma) is shown to correlate with vaccine efficacy. Thus, an enzyme-linked immunosorbent assay (ELISA)-based binding assay to detect SARS-CoV-2 (ancestral and variant strains) anti-rS IgG in human serum samples was developed and validated. This assay successfully met acceptance criteria for inter/intra-assay precision, specificity, selectivity, linearity, lower/upper limits of quantitation, matrix effects, and assay robustness. The analyte in serum was stable for up to 8 freeze/thaw cycles and 2 years in −80 °C storage. Similar results were observed for the Beta, Delta, and Omicron BA.1/BA.5/XBB.1.5 variant-adapted assays. Anti-rS IgG assay results correlated significantly with neutralization and receptor binding inhibition assays. In addition, usage of international reference standards allows data extrapolation to WHO international units (BAU/mL), facilitating comparison of results with other IgG assays. This anti-rS IgG assay is a robust, high-throughput method to evaluate binding IgG responses to S protein in serum, enabling rapid development of effective vaccines against emerging COVID-19 variants.