Thomaskutty Mathew
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Thomaskutty Mathew has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Anoop Chandrika Sreekantan
Department of Avionics, Indian Institute of Space Science and Technology, Trivandrum, India
5 shared publications - K. Elangovan
Department of Electronics and Communication Engineering, Indian Institute of Information Technology, Design and Manufacturing, Kurnool, India
2 shared publications - Nani Simhadri
Department of Avionics, Indian Institute of Space Science and Technology, Thiruvananthapuram, India
2 shared publications - Vineeth Bala Sukumaran
Department of Avionics, Indian Institute of Space Science and Technology, Thiruvananthapuram, India
2 shared publications Abhay Renjith T J
Department of Avionics, Indian Institute of Space Science and Technology, Trivandrum, India
1 shared publicationAryan Sharma
Department of Avionics, Indian Institute of Space Science and Technology, Trivandrum, India
1 shared publication
Latest Publications
- 2 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 10 (3) , 1-4
A GMR-Based Smart Respiration Belt for Noninvasive Real-Time Monitoring
Respiration rate (RR) is a vital physiological parameter, yet conventional measurement methods are often invasive, inaccurate, or unsuitable for continuous monitoring. This letter presents a wearable respiration monitoring belt for continuous and noninvasive measurement of breathing activity. The system employs a giant magnetoresistance sensor with a paired neodymium magnet to detect chest movements, with the optimal spacing determined through finite-element simulations. An instrumentation amplifier, equipped with a DC servo loop, and a low-pass filter enable robust signal acquisition, while a microcontroller computes the RR in real time. Validation on 12 healthy volunteers showed a maximum error of $\pm$ 2 breaths per minute compared with a BIOPAC reference, confirming accuracy and stability. Due to its compact size, low power consumption, and skin-contact-free operation, the proposed system shows strong potential for applications in remote health care, sleep apnea detection, and automotive safety.
- 2 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 10 (3) , 1-4
A GMR-Based Smart Respiration Belt for Noninvasive Real-Time Monitoring
Respiration rate (RR) is a vital physiological parameter, yet conventional measurement methods are often invasive, inaccurate, or unsuitable for continuous monitoring. This letter presents a wearable respiration monitoring belt for continuous and noninvasive measurement of breathing activity. The system employs a giant magnetoresistance sensor with a paired neodymium magnet to detect chest movements, with the optimal spacing determined through finite-element simulations. An instrumentation amplifier, equipped with a DC servo loop, and a low-pass filter enable robust signal acquisition, while a microcontroller computes the RR in real time. Validation on 12 healthy volunteers showed a maximum error of $\pm$ 2 breaths per minute compared with a BIOPAC reference, confirming accuracy and stability. Due to its compact size, low power consumption, and skin-contact-free operation, the proposed system shows strong potential for applications in remote health care, sleep apnea detection, and automotive safety.
- 31 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 10 (2) , 1-4
A Smart Dual-Thermistor-Based Nasal Mask for Respiratory Health Monitoring
In this letter, we propose a low-cost, portable, and wearable smart nasal thermistor mask with associated electronics for continuous respiration monitoring. A commercially available mask incorporating a thermistor realizes the smart mask. The abovementioned thermistor, along with another thermistor for ambient temperature monitoring, together realize a dual-thermistor bridge. The output voltage of the bridge topology interfacing the above dual thermistor is amplified using an instrumentation amplifier stage. The above signal was signal-conditioned, and the respiration rate of the subject was inferred. The accuracy in measurement was tested using 20 healthy volunteers of various age groups. The resulting error was less than 1 breaths per minute. The developed prototype was tested with different states of the subject, likewise during exercise and during a short nap. A comprehensive sensitivity study of the acquired biosignal was performed for different positions of sensor placement. The potential applications of the smart mask include integration with telemedicine, advanced driver assistance systems, and in space applications.
- 31 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 10 (2) , 1-4
A Smart Dual-Thermistor-Based Nasal Mask for Respiratory Health Monitoring
In this letter, we propose a low-cost, portable, and wearable smart nasal thermistor mask with associated electronics for continuous respiration monitoring. A commercially available mask incorporating a thermistor realizes the smart mask. The abovementioned thermistor, along with another thermistor for ambient temperature monitoring, together realize a dual-thermistor bridge. The output voltage of the bridge topology interfacing the above dual thermistor is amplified using an instrumentation amplifier stage. The above signal was signal-conditioned, and the respiration rate of the subject was inferred. The accuracy in measurement was tested using 20 healthy volunteers of various age groups. The resulting error was less than 1 breaths per minute. The developed prototype was tested with different states of the subject, likewise during exercise and during a short nap. A comprehensive sensitivity study of the acquired biosignal was performed for different positions of sensor placement. The potential applications of the smart mask include integration with telemedicine, advanced driver assistance systems, and in space applications.
- Open Access
- 1 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Instrumentation and Measurement
- Vol. 4, 1-10
A Versatile Loop-Compensated Interface for Nonlinear Resistive Sensor Bridges Applied to Linearized Thermistor Temperature Sensing
Resistive sensors are commonly available in bridge configurations. This paper presents a versatile interfacing circuit topology suitable for various types of resistive sensor bridges exhibiting nonlinear output characteristics. The proposed topology employs an electronic loop compensation approach capable of operating in single-mode or dual-mode configurations. In addition to the sensor bridge, the core elements of the loop include a two-stage instrumentation amplifier and a novel switching logic. The circuit can accommodate different bridge types—including single-element, special dual-element, and thermistor-based sensor bridges—and produces an output that varies proportionally with the sensed variable. The innovative switching logic minimizes the influence of switching resistance on the output, thereby enhancing the measurement accuracy. The thermistor-based interface involves an optimization method using an evolutionary algorithm-based technique. This study considers various practical constraints, such as maintaining sufficient sensitivity and limiting the self-heating errors. The prominent error sources are analyzed and quantified. The performance evaluation of the developed scheme was tested in simulation, emulation, and experimental studies (using a commercial thermistor). The proposed topology provides a close to linear output characteristic on interfacing with a thermistor. The associated nonlinearity is 0.48% over 0 ∘ to 120 ∘ range, with a reasonable sensitivity of 23.5 mV/∘C. Finally, a quantitative analysis of the developed scheme is conducted among recent loop compensator-based sensor linearizers.
- 1 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Instrumentation and Measurement
- Vol. 4, 1-10
Open AccessA Versatile Loop-Compensated Interface for Nonlinear Resistive Sensor Bridges Applied to Linearized Thermistor Temperature Sensing
Resistive sensors are commonly available in bridge configurations. This paper presents a versatile interfacing circuit topology suitable for various types of resistive sensor bridges exhibiting nonlinear output characteristics. The proposed topology employs an electronic loop compensation approach capable of operating in single-mode or dual-mode configurations. In addition to the sensor bridge, the core elements of the loop include a two-stage instrumentation amplifier and a novel switching logic. The circuit can accommodate different bridge types—including single-element, special dual-element, and thermistor-based sensor bridges—and produces an output that varies proportionally with the sensed variable. The innovative switching logic minimizes the influence of switching resistance on the output, thereby enhancing the measurement accuracy. The thermistor-based interface involves an optimization method using an evolutionary algorithm-based technique. This study considers various practical constraints, such as maintaining sufficient sensitivity and limiting the self-heating errors. The prominent error sources are analyzed and quantified. The performance evaluation of the developed scheme was tested in simulation, emulation, and experimental studies (using a commercial thermistor). The proposed topology provides a close to linear output characteristic on interfacing with a thermistor. The associated nonlinearity is 0.48% over 0 ∘ to 120 ∘ range, with a reasonable sensitivity of 23.5 mV/∘C. Finally, a quantitative analysis of the developed scheme is conducted among recent loop compensator-based sensor linearizers.
- 25 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (24) , 41099-41109
A Digital Thermistor Read-Out Based on Charge-Discharge Topologies Coupled With Optimal Linearization Strategies
This paper proposes a simple and low-component count linearizing digitizer for thermistor interfacing. The proposed digitizer employs a simple charge-discharge thermistor interface that selectively charges and discharges a capacitor between two voltage thresholds. This circuit aids in the thermistor linearization, requiring just two conversion cycles (as opposed to five in prior art) for its operation. The paper first presents a single-mode linearizing digitizer whose non-linearity is minimized using the optimal choice of a resistance value. This is followed by the discussion of a multi-mode hybrid digitizing approach and associated new linearization function (with nonlinearity minimized using the optimal choice of a resistance value and software-implemented parameters). The differential evolution algorithm is employed for optimization, wherein important practical constraints are considered. The potential error sources are analyzed and quantified. Further, the performance analysis of the proposed schemes is performed using simulation and hardware-based experimental studies. The results demonstrate the ability of the developed schemes to render linear digital output characteristics when interfacing with typical thermistor operating over different temperature spans. The maximum nonlinearity of the developed hybrid-based digitizer observed during experimentation is 0.42% for 5 °C to 45 °C and 1.28% for 0 °C to 120 °C. A detailed comparison of the proposed digitizer with contemporary thermistor linearizers is also reported in this paper.
- 25 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (24) , 41099-41109
A Digital Thermistor Read-Out Based on Charge-Discharge Topologies Coupled With Optimal Linearization Strategies
This paper proposes a simple and low-component count linearizing digitizer for thermistor interfacing. The proposed digitizer employs a simple charge-discharge thermistor interface that selectively charges and discharges a capacitor between two voltage thresholds. This circuit aids in the thermistor linearization, requiring just two conversion cycles (as opposed to five in prior art) for its operation. The paper first presents a single-mode linearizing digitizer whose non-linearity is minimized using the optimal choice of a resistance value. This is followed by the discussion of a multi-mode hybrid digitizing approach and associated new linearization function (with nonlinearity minimized using the optimal choice of a resistance value and software-implemented parameters). The differential evolution algorithm is employed for optimization, wherein important practical constraints are considered. The potential error sources are analyzed and quantified. Further, the performance analysis of the proposed schemes is performed using simulation and hardware-based experimental studies. The results demonstrate the ability of the developed schemes to render linear digital output characteristics when interfacing with typical thermistor operating over different temperature spans. The maximum nonlinearity of the developed hybrid-based digitizer observed during experimentation is 0.42% for 5 °C to 45 °C and 1.28% for 0 °C to 120 °C. A detailed comparison of the proposed digitizer with contemporary thermistor linearizers is also reported in this paper.
- 10 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-4
Accurate Interface Schemes for Resistance Thermometers With Lead Resistance Compensation
Simple low-cost interfacing circuits for resistance thermometers are proposed in this paper. The proposed circuits are designed to provide many salient features, including simplicity of architecture, lead-wire compensation, constant-current excitation, and requirement of minimal number of analog-to-digital converters for digitization. The first of the proposed circuits uses a twin-Op-amp signal conditioner for three-wire sensor. This circuit is then modified to act as an efficient front-end for four-wire resistance thermometer, and thus negate the effect of lead-wire mismatches. The performance of the proposed circuits is extensively verified using experimental studies. Results show that the nonlinearity and relative error of the developed circuits is less than 0.05% and 0.32%, respectively, when tested with Pt1000 sensor. Finally, a comparison study is performed to show the superiority of the proposed techniques.
- 10 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-4
Accurate Interface Schemes for Resistance Thermometers With Lead Resistance Compensation
Simple low-cost interfacing circuits for resistance thermometers are proposed in this paper. The proposed circuits are designed to provide many salient features, including simplicity of architecture, lead-wire compensation, constant-current excitation, and requirement of minimal number of analog-to-digital converters for digitization. The first of the proposed circuits uses a twin-Op-amp signal conditioner for three-wire sensor. This circuit is then modified to act as an efficient front-end for four-wire resistance thermometer, and thus negate the effect of lead-wire mismatches. The performance of the proposed circuits is extensively verified using experimental studies. Results show that the nonlinearity and relative error of the developed circuits is less than 0.05% and 0.32%, respectively, when tested with Pt1000 sensor. Finally, a comparison study is performed to show the superiority of the proposed techniques.