SCSijie Chen

Sijie Chen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sijie Chen has a total of 5 co-authors. Here are the top co-authors by number of shared publications:

  • Chris J. Ruiken

    Waternet, Korte Ouderkerkerdijk 7, 1096 AC Amsterdam, The Netherlands

    1 shared publication
  • Emile R. Cornelissen

    Particle and Interfacial Technology (PaInT), Ghent University, Coupure Links 653, 9000, Ghent, Belgium; Center for Advanced Process Technology for Urban Resource Recovery (CAPTURE), Ghent University, Frieda Saeysstraat 1, 9052, Ghent, Belgium; KWR Water Research Institute, Groningenhaven 7, 3433 PE, Nieuwegein, the Netherlands

    1 shared publication
  • Jian-Jun Qin

    Technology Department & Water Quality Office, PUB Singapore’s National Water Agency, Singapore, Tel. +65 63262931, Tel. +65 63262926, Tel. +65 63262914; Fax: +65 63262929

    1 shared publication
  • Kiran A. Kekre

    Technology & Water Quality Office, Public Utilities Board, Singapore;

    1 shared publication
  • Maung Htun Oo

    Technology and Water Quality Office, Public Utilities Board, 82 Toh Guan Road East, #C4-03, 608575 Singapore, Republic of Singapore;

    1 shared publication

Latest Publications

  • Experimental studies and modeling on concentration polarization in forward osmosis

    by Jian-Jun Qin, Sijie Chen, Maung Htun Oo, Kiran A Kekre, Emile R. Cornelissen, Chris J. Ruiken

    Concentration polarization (CP) is an important issue in forward osmosis (FO) processes and it is believed that the coupled effect of dilutive internal CP (DICP) and concentrative external CP (CECP) limits FO flux. The objective of this study was to distinguish individual contribution of different types of DICP and CECP via modeling and to validate it by pilot studies. The influence of DICP/CECP on FO flux has been investigated in this study. The CP model presented in this work was derived from a previous study and evaluated by bench-scale FO experiments. Experiments were conducted with drinking water as the feed and NaCl/MgSO4 as draw solutions at different concentrations and velocities. Modeling results indicated that DICP contributed to a flux reduction by 99.9% for 0.5 M NaCl as a draw solution although the flow pattern of both feed and draw solutions was turbulent. DICP could be improved via selection of the draw solution. The modeling results were well fit with the experimental data. It was concluded that the model could be used for selection of the draw solution and prediction of water flux under similar situation. A draw solution with greater diffusion coefficient or a thinner substrate of an asymmetric FO membrane resulted in a higher flux.