Paul-Albert Schneide
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Paul-Albert Schneide has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Neal B. Gallagher
2 shared publicationsNeal Gallagher
2 shared publicationsRasmus Bro
2 shared publications- Rasmus Bro
University of Copenhagen
2 shared publications Aleksandra Lelevic
IFP Energies Nouvelles, Rond-Point de l’É changeur de Solaize, BP 3, Solaize 69360, France
1 shared publicationJesper Løve Hinrich
1 shared publication
Latest Publications
- 5 May 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (19) , 14330-14338
Adapting Tile-Based Discovery Analysis for Comprehensive Two-Dimensional Gas Chromatography with Vacuum Ultraviolet Spectroscopy Data of Gas Oils
To address the challenge of comparing entire chromatograms, three tile-based comparative analysis methods (Fisher ratio, pairwise, and relative variance ranking) were applied to data collected by comprehensive two-dimensional gas chromatography with vacuum ultraviolet spectroscopy detection (GC × GC-VUV). The tile-based scheme, originally developed for time-of-flight mass spectrometry (TOFMS) detection, was adapted herein to rank analytes on a hit list according to the metric for each method. We analyzed a GC × GC-VUV data set comprising 14 gas oils from five sample classes: straight-run (SR), light cycle oil (LCO), coker (CK), hydroconverted (HDC), and hydrotreated (HDT). Three replicates each of HDT and LCO gas oil GC × GC-VUV data were analyzed by Fisher ratio analysis with 459 out of 557 analyte hits exhibiting at least a 2-fold change, which were visualized by 2D chromatogram projections. Additionally, multivariate curve resolution-alternating least-squares was applied to obtain the pure VUV spectrum of each analyte, which was readily classified into five compound classes (saturates, olefins, mono-, di-, and triaromatics) and projected onto the 2D separation space to visualize the positions of these compound classes. Next, pairwise analysis, either between replicates of the same sample or between samples within the same sample class was studied. A concentration ratio >1.2 was determined as the 99% confidence level threshold for distinguishing analyte hits from background variation. Finally, relative variance analysis of all 24 gas oil chromatograms combined with principal component analysis enabled unsupervised differentiation of the five gas oil sample classes.
- 5 May 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (19) , 14330-14338
Adapting Tile-Based Discovery Analysis for Comprehensive Two-Dimensional Gas Chromatography with Vacuum Ultraviolet Spectroscopy Data of Gas Oils
To address the challenge of comparing entire chromatograms, three tile-based comparative analysis methods (Fisher ratio, pairwise, and relative variance ranking) were applied to data collected by comprehensive two-dimensional gas chromatography with vacuum ultraviolet spectroscopy detection (GC × GC-VUV). The tile-based scheme, originally developed for time-of-flight mass spectrometry (TOFMS) detection, was adapted herein to rank analytes on a hit list according to the metric for each method. We analyzed a GC × GC-VUV data set comprising 14 gas oils from five sample classes: straight-run (SR), light cycle oil (LCO), coker (CK), hydroconverted (HDC), and hydrotreated (HDT). Three replicates each of HDT and LCO gas oil GC × GC-VUV data were analyzed by Fisher ratio analysis with 459 out of 557 analyte hits exhibiting at least a 2-fold change, which were visualized by 2D chromatogram projections. Additionally, multivariate curve resolution-alternating least-squares was applied to obtain the pure VUV spectrum of each analyte, which was readily classified into five compound classes (saturates, olefins, mono-, di-, and triaromatics) and projected onto the 2D separation space to visualize the positions of these compound classes. Next, pairwise analysis, either between replicates of the same sample or between samples within the same sample class was studied. A concentration ratio >1.2 was determined as the 99% confidence level threshold for distinguishing analyte hits from background variation. Finally, relative variance analysis of all 24 gas oil chromatograms combined with principal component analysis enabled unsupervised differentiation of the five gas oil sample classes.
- 7 January 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (2) , 1180-1189
Signal Processing Workflow for Suspect Screening in LC × LC-HRMS: Efficient Extraction of Pure Mass Spectra for Identification of Suspects in Complex Samples Using a Mass Filtering Algorithm
The data processing workflows for comprehensive two-dimensional liquid chromatography (LC × LC) hyphenated to high-resolution mass spectrometry (HRMS) operated in data-independent acquisition (DIA) are limited compared to their one-dimensional counterparts. A two-step workflow is proposed to extract pure mass spectra from LC × LC-HRMS. First, a mass filtering (MF) algorithm groups ions belonging to the same compound based on their elution profile similarity in the first (1D) and second dimension (2D). Second, the filtered data are deconvoluted using multivariate curve resolution (MCR) to address potential coelution. The presented workflow is termed MF + MCR and was tested on pulsed elution-LC × LC-HRMS data from a wastewater effluent extract. The proposed workflow was benchmarked to the following three data processing strategies for mass spectra extraction: peak apex (PAM), using the MF approach alone, or using MCR without prior MF. The MF + MCR workflow identified 25 suspect compounds, compared to 23, 16, and 10 identified by MF, MCR, and PAM, respectively. The nine suspects that could not be identified using MCR compared to the MF + MCR all had low total signal contributions, i.e., low intensities compared to the TIC. This showed that adequate preprocessing prior to MCR is essential for trace level analysis. Additionally, it was shown that the MF + MCR workflow extracted statistically significantly purer mass spectra compared to PAM (p-value: 0.003) and MCR (p-value: 0.04) from a spiked blank sample. The results highlight that by utilizing the elution profiles in both chromatographic dimensions, clean mass spectra of analytes at trace levels measured in DIA can be extracted, allowing for more reliable compound identification compared to the workflows that were used for benchmarking.
- 7 January 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (2) , 1180-1189
Signal Processing Workflow for Suspect Screening in LC × LC-HRMS: Efficient Extraction of Pure Mass Spectra for Identification of Suspects in Complex Samples Using a Mass Filtering Algorithm
The data processing workflows for comprehensive two-dimensional liquid chromatography (LC × LC) hyphenated to high-resolution mass spectrometry (HRMS) operated in data-independent acquisition (DIA) are limited compared to their one-dimensional counterparts. A two-step workflow is proposed to extract pure mass spectra from LC × LC-HRMS. First, a mass filtering (MF) algorithm groups ions belonging to the same compound based on their elution profile similarity in the first (1D) and second dimension (2D). Second, the filtered data are deconvoluted using multivariate curve resolution (MCR) to address potential coelution. The presented workflow is termed MF + MCR and was tested on pulsed elution-LC × LC-HRMS data from a wastewater effluent extract. The proposed workflow was benchmarked to the following three data processing strategies for mass spectra extraction: peak apex (PAM), using the MF approach alone, or using MCR without prior MF. The MF + MCR workflow identified 25 suspect compounds, compared to 23, 16, and 10 identified by MF, MCR, and PAM, respectively. The nine suspects that could not be identified using MCR compared to the MF + MCR all had low total signal contributions, i.e., low intensities compared to the TIC. This showed that adequate preprocessing prior to MCR is essential for trace level analysis. Additionally, it was shown that the MF + MCR workflow extracted statistically significantly purer mass spectra compared to PAM (p-value: 0.003) and MCR (p-value: 0.04) from a spiked blank sample. The results highlight that by utilizing the elution profiles in both chromatographic dimensions, clean mass spectra of analytes at trace levels measured in DIA can be extracted, allowing for more reliable compound identification compared to the workflows that were used for benchmarking.
- 5 December 2024
- Published by Wiley in Journal of Chemometrics
- Vol. 39 (1)
Unlocking New Capabilities in the Analysis of GC × GC‐TOFMS Data With Shift‐Invariant Multi‐Linearity
This paper introduces a novel deconvolution algorithm, shift‐invariant multi‐linearity (SIML), which significantly enhances the analysis of data from two‐dimensional gas chromatography instruments coupled to a time‐of‐flight mass spectrometer (GC × GC‐TOFMS). Designed to address the challenges posed by retention time shifts and high noise levels, SIML incorporates wavelet‐based smoothing and Fourier‐transform based shift‐correction within the multivariate curve resolution‐alternating least squares (MCR‐ALS) framework. We benchmarked the SIML algorithm against non‐negativity constrained MCR‐ALS and parallel factor analysis 2 with flexible coupling (PARAFAC2 × N) using both simulated and real GC × GC‐TOFMS datasets. Our results demonstrate that SIML provides unique solutions with significantly improved robustness, particularly in low signal‐to‐noise ratio scenarios, where it maintains high accuracy in estimating mass spectra and concentrations. The enhanced reliability of quantitative analyses afforded by SIML underscores its potential for broad application in complex matrix analyses across environmental science, food science, and biological research.
- 5 December 2024
- Published by Wiley in Journal of Chemometrics
- Vol. 39 (1)
Unlocking New Capabilities in the Analysis of GC × GC‐TOFMS Data With Shift‐Invariant Multi‐Linearity
This paper introduces a novel deconvolution algorithm, shift‐invariant multi‐linearity (SIML), which significantly enhances the analysis of data from two‐dimensional gas chromatography instruments coupled to a time‐of‐flight mass spectrometer (GC × GC‐TOFMS). Designed to address the challenges posed by retention time shifts and high noise levels, SIML incorporates wavelet‐based smoothing and Fourier‐transform based shift‐correction within the multivariate curve resolution‐alternating least squares (MCR‐ALS) framework. We benchmarked the SIML algorithm against non‐negativity constrained MCR‐ALS and parallel factor analysis 2 with flexible coupling (PARAFAC2 × N) using both simulated and real GC × GC‐TOFMS datasets. Our results demonstrate that SIML provides unique solutions with significantly improved robustness, particularly in low signal‐to‐noise ratio scenarios, where it maintains high accuracy in estimating mass spectra and concentrations. The enhanced reliability of quantitative analyses afforded by SIML underscores its potential for broad application in complex matrix analyses across environmental science, food science, and biological research.
- Open Access
- 12 June 2024
- Published by Elsevier in Chemometrics and Intelligent Laboratory Systems
- Vol. 251
Shift invariant soft trilinearity: Modelling shifts and shape changes in gas-chromatography coupled mass spectrometry
- 12 June 2024
- Published by Elsevier in Chemometrics and Intelligent Laboratory Systems
- Vol. 251
Open AccessShift invariant soft trilinearity: Modelling shifts and shape changes in gas-chromatography coupled mass spectrometry
- Open Access
- 26 June 2023
- Published by Wiley in Journal of Chemometrics
- Vol. 37 (8)
Shift‐invariant tri‐linearity—A new model for resolving untargeted gas chromatography coupled mass spectrometry data
Multi‐way data analysis is popular in chemometrics for the decomposition of, for example, spectroscopic or chromatographic higher‐order tensor datasets. Parallel factor analysis (PARAFAC) and its extension, PARAFAC2, are extensively employed methods in chemometrics. Applications of PARAFAC2 for untargeted data analysis of hyphenated gas chromatography coupled with mass spectrometric detection (GC‐MS) have proven to be very successful. This is attributable to the ability of PARAFAC2 to account for retention time shifts and shape changes in chromatographic elution profiles. Despite its usefulness, the most common implementations of PARAFAC2 are considered quite slow. Furthermore, it is difficult to apply constraints (e.g., non‐negativity) to the shifted mode in PARAFAC2 models. Both aspects are addressed by a new shift‐invariant tri‐linearity (SIT) algorithm proposed in this paper. It is shown on simulated and real GC‐MS data that the SIT algorithm is 20–60 times faster than the latest PARAFAC2‐alternating least squares (ALS) implementation and the PARAFAC2‐flexible coupling algorithm. Further, the SIT method allows the implementation of constraints in all modes. Trials on real‐world data indicate that the SIT algorithm compares well with alternatives. The new SIT method achieves better factor resolution than the benchmark in some cases and tends to need fewer latent variables to extract the same chemical information. Although SIT is not capable of modeling shape changes in elution profiles, trials on real‐world data indicate the great robustness of the method even in those cases.
- 26 June 2023
- Published by Wiley in Journal of Chemometrics
- Vol. 37 (8)
Open AccessShift‐invariant tri‐linearity—A new model for resolving untargeted gas chromatography coupled mass spectrometry data
Multi‐way data analysis is popular in chemometrics for the decomposition of, for example, spectroscopic or chromatographic higher‐order tensor datasets. Parallel factor analysis (PARAFAC) and its extension, PARAFAC2, are extensively employed methods in chemometrics. Applications of PARAFAC2 for untargeted data analysis of hyphenated gas chromatography coupled with mass spectrometric detection (GC‐MS) have proven to be very successful. This is attributable to the ability of PARAFAC2 to account for retention time shifts and shape changes in chromatographic elution profiles. Despite its usefulness, the most common implementations of PARAFAC2 are considered quite slow. Furthermore, it is difficult to apply constraints (e.g., non‐negativity) to the shifted mode in PARAFAC2 models. Both aspects are addressed by a new shift‐invariant tri‐linearity (SIT) algorithm proposed in this paper. It is shown on simulated and real GC‐MS data that the SIT algorithm is 20–60 times faster than the latest PARAFAC2‐alternating least squares (ALS) implementation and the PARAFAC2‐flexible coupling algorithm. Further, the SIT method allows the implementation of constraints in all modes. Trials on real‐world data indicate that the SIT algorithm compares well with alternatives. The new SIT method achieves better factor resolution than the benchmark in some cases and tends to need fewer latent variables to extract the same chemical information. Although SIT is not capable of modeling shape changes in elution profiles, trials on real‐world data indicate the great robustness of the method even in those cases.