Hatice Bilge
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hatice Bilge has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Nazmiye Donmez Kesen
Division of Medical Physics, Istanbul University Oncology Institute, Istanbul, Turkey
2 shared publications Aydin Cakir
Radiotherapy Department, Istanbul University Oncology Institute, Fatih, Capa, 34390 Istanbul, Turkey
1 shared publication- Canan Koksal
Department of Medical Physics, Institute of Oncology, Istanbul University, 34093 Istanbul, Türkiye
1 shared publication - Gokce Ucar Alveroglu
Istanbul University Oncology Institute, Turkey
1 shared publication Inci Kingir Celtik
1 shared publication- Murat Okutan
Universty of Istanbul, Oncology Instıtute, Department of Medical Physics, Istanbul Turkey
1 shared publication
Latest Publications
- Open Access
- 1 January 2022
- Published by RAD Centre
Dose comparison of total body irradiation in different treatment planning system algorithms
- 1 January 2022
- Published by RAD Centre
Open AccessDose comparison of total body irradiation in different treatment planning system algorithms
- Open Access
- 25 March 2014
- Published by Wiley in Science and Technology of Nuclear Installations
- Vol. 2014, 1-6
Research of Dosimetry Parameters in Small Electron Beams
In this study, dose distributions and outputs of circular fields with dimensions of 5 cm and smaller, for 6 and 9 MeV nominal energies from the Siemens ONCOR Linac, were measured and compared with data from a treatment planning system using the pencil beam algorithm in electron beam calculations. All dose distribution measurements were performed using the GafChromic EBT film; these measurements were compared with data that were obtained from the Computerized Medical Systems (CMS) XiO treatment planning system (TPS). Output measurements were performed using GafChromic EBT film, an Advanced Markus ion chamber, and thermoluminescent dosimetry (TLD). Although it is used in many clinics, there is not a substantial amount of detailed information in the literature about use of the pencil beam algorithm to model electron beams. Output factors were consistent; differences from the values obtained from the TPS were at maximum. When the dose distributions from the TPS were compared with the measurements from the ion chamber and GafChromic EBT films, it was observed that the results were consistent with 2 cm diameter fields and larger, but the outputs for 1 cm diameter fields and smaller were not consistent.
- 25 March 2014
- Published by Wiley in Science and Technology of Nuclear Installations
- Vol. 2014, 1-6
Open AccessResearch of Dosimetry Parameters in Small Electron Beams
In this study, dose distributions and outputs of circular fields with dimensions of 5 cm and smaller, for 6 and 9 MeV nominal energies from the Siemens ONCOR Linac, were measured and compared with data from a treatment planning system using the pencil beam algorithm in electron beam calculations. All dose distribution measurements were performed using the GafChromic EBT film; these measurements were compared with data that were obtained from the Computerized Medical Systems (CMS) XiO treatment planning system (TPS). Output measurements were performed using GafChromic EBT film, an Advanced Markus ion chamber, and thermoluminescent dosimetry (TLD). Although it is used in many clinics, there is not a substantial amount of detailed information in the literature about use of the pencil beam algorithm to model electron beams. Output factors were consistent; differences from the values obtained from the TPS were at maximum. When the dose distributions from the TPS were compared with the measurements from the ion chamber and GafChromic EBT films, it was observed that the results were consistent with 2 cm diameter fields and larger, but the outputs for 1 cm diameter fields and smaller were not consistent.