Jiawu Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jiawu Li has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Buyun Ma
Department of Ultrasound, West China Hospital, Sichuan University, Chengdu 610041, China
1 shared publication - Jinzhen Song
Department of Abdominal Ultrasound, The Affiliated Hospital of Qingdao University, Qingdao
1 shared publication - Juanmei Chen
Department of Ultrasound, West China Hospital, Sichuan University, Chengdu 610041, China
1 shared publication - Qiang Lu
Department of Ultrasound, West China Hospital of Sichuan University, Chengdu, China
1 shared publication - Ruiheng Ye
Department of Ultrasound Medicine, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou 510120, China
1 shared publication - Yan Luo
Department of Ultrasound, West China Hospital of Sichuan University, Chengdu, People’s Republic of China
1 shared publication
Latest Publications
- Open Access
- 19 June 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (12) , 1909
Deep Learning Based on B-Mode and Color Doppler Ultrasound for Differentiation of Primary Thyroid Lymphoma and Hashimoto’s Thyroiditis: A Retrospective Single-Center Study
Background/Objectives: Primary thyroid lymphoma (PTL), including diffuse large B-cell lymphoma (DLBCL) and mucosa-associated lymphoid tissue (MALT) lymphoma, share substantial overlap in ultrasound appearance with Hashimoto’s thyroiditis (HT), making preoperative differentiation challenging. This study aims to develop and validate a deep learning model based on B-mode ultrasound (BMUS) and color Doppler ultrasound (CDUS) for image-level differentiation of DLBCL, MALT lymphoma, and HT. Methods: This retrospective single-center study included 1294 ultrasound images from 290 patients (313 lesions) who underwent preoperative ultrasound examination at West China Hospital between September 2002 and September 2024. All images from the same lesion were assigned to the same data partition, and the dataset was split at the lesion level into training and test sets at an 8:2 ratio. A Frequency-Adaptive WT-ResNet model incorporating wavelet transform convolution and a frequency-adaptive gating mechanism was developed. The primary analysis was performed at the image level. The performance of the model was compared with that of three ultrasound physicians with different levels of experience. Grad-CAM was used for visual interpretation. An exploratory external validation was performed using an independent dataset from Sun Yat-sen Memorial Hospital. Results: In the test set, the model achieved a macro-average AUC of 0.927 (95% CI: 0.889–0.960), with class-specific AUCs of 0.899 for DLBCL, 0.946 for MALT lymphoma, and 0.937 for HT. The macro-average balanced accuracy was 0.866, compared with 0.827 for that of the best-performing senior physician. The exploratory validation set yielded a macro-average AUC of 0.796 (95% CI: 0.686–0.888), with class-specific AUCs of 0.806 for DLBCL, 0.825 for HT, and 0.756 for MALT lymphoma. Grad-CAM showed that the model focused on lesion-internal echotexture and lesion-transition regions with class-dependent patterns. Conclusions: A deep learning model based on BMUS and CDUS showed promising performance for image-level differentiation of DLBCL, MALT lymphoma and HT in a single-center retrospective cohort. The model outperformed three ultrasound physicians and may serve as a potential decision-support tool. However, the exploratory external validation results should be interpreted as preliminary, and larger multicenter cohorts remain necessary to confirm model generalizability.
- 19 June 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (12) , 1909
Open AccessDeep Learning Based on B-Mode and Color Doppler Ultrasound for Differentiation of Primary Thyroid Lymphoma and Hashimoto’s Thyroiditis: A Retrospective Single-Center Study
Background/Objectives: Primary thyroid lymphoma (PTL), including diffuse large B-cell lymphoma (DLBCL) and mucosa-associated lymphoid tissue (MALT) lymphoma, share substantial overlap in ultrasound appearance with Hashimoto’s thyroiditis (HT), making preoperative differentiation challenging. This study aims to develop and validate a deep learning model based on B-mode ultrasound (BMUS) and color Doppler ultrasound (CDUS) for image-level differentiation of DLBCL, MALT lymphoma, and HT. Methods: This retrospective single-center study included 1294 ultrasound images from 290 patients (313 lesions) who underwent preoperative ultrasound examination at West China Hospital between September 2002 and September 2024. All images from the same lesion were assigned to the same data partition, and the dataset was split at the lesion level into training and test sets at an 8:2 ratio. A Frequency-Adaptive WT-ResNet model incorporating wavelet transform convolution and a frequency-adaptive gating mechanism was developed. The primary analysis was performed at the image level. The performance of the model was compared with that of three ultrasound physicians with different levels of experience. Grad-CAM was used for visual interpretation. An exploratory external validation was performed using an independent dataset from Sun Yat-sen Memorial Hospital. Results: In the test set, the model achieved a macro-average AUC of 0.927 (95% CI: 0.889–0.960), with class-specific AUCs of 0.899 for DLBCL, 0.946 for MALT lymphoma, and 0.937 for HT. The macro-average balanced accuracy was 0.866, compared with 0.827 for that of the best-performing senior physician. The exploratory validation set yielded a macro-average AUC of 0.796 (95% CI: 0.686–0.888), with class-specific AUCs of 0.806 for DLBCL, 0.825 for HT, and 0.756 for MALT lymphoma. Grad-CAM showed that the model focused on lesion-internal echotexture and lesion-transition regions with class-dependent patterns. Conclusions: A deep learning model based on BMUS and CDUS showed promising performance for image-level differentiation of DLBCL, MALT lymphoma and HT in a single-center retrospective cohort. The model outperformed three ultrasound physicians and may serve as a potential decision-support tool. However, the exploratory external validation results should be interpreted as preliminary, and larger multicenter cohorts remain necessary to confirm model generalizability.
- Open Access
- 29 March 2022
- Published by Wolters Kluwer Health in Ultrasound Quarterly
- Vol. 38 (2) , 155-159
Can Location of Stiffness Measurement Impact Spleen 2-Dimensional Shear Wave Elastography Measurement?
Ultrasound-based spleen elastography is a promising surrogate to predict portal hypertension noninvasively. In contrast to defined standards for liver stiffness measurement, the standardized examination procedures for 2-dimensional (2D) shear wave elastography spleen elastography have not been established yet. The aim was to investigate the impact of location of stiffness measurement on 2D shear wave elastography spleen stiffness measurement (SSM). Patients with splenomegaly were enrolled. Both B-mode ultrasound and elastography of spleen were performed. For SSM, 3 regions were chosen for spleen measurement: lower pole region, central region, and the region between lower pole and center. Mean SSM value, success rate, and reliability predicators (standard deviation, standard deviation/mean, size of region of interest) were assessed. A total of 124 patients were included. For mean SSM value, there were no significant differences among 3 regions. Spleen stiffness measurement success rate in lower pole region, central region, and the region between them was 63.7% (79), 91.1% (113), and 78.2% (97), respectively. The success rate in the central region was significantly higher than that in the other 2 regions (P < 0.05). Reliability in the central region was also highest among the 3 regions. Location of stiffness measurement has a limited effect on SSM. Changing location of measurement will not influence mean stiffness value in spleen.
- 29 March 2022
- Published by Wolters Kluwer Health in Ultrasound Quarterly
- Vol. 38 (2) , 155-159
Open AccessCan Location of Stiffness Measurement Impact Spleen 2-Dimensional Shear Wave Elastography Measurement?
Ultrasound-based spleen elastography is a promising surrogate to predict portal hypertension noninvasively. In contrast to defined standards for liver stiffness measurement, the standardized examination procedures for 2-dimensional (2D) shear wave elastography spleen elastography have not been established yet. The aim was to investigate the impact of location of stiffness measurement on 2D shear wave elastography spleen stiffness measurement (SSM). Patients with splenomegaly were enrolled. Both B-mode ultrasound and elastography of spleen were performed. For SSM, 3 regions were chosen for spleen measurement: lower pole region, central region, and the region between lower pole and center. Mean SSM value, success rate, and reliability predicators (standard deviation, standard deviation/mean, size of region of interest) were assessed. A total of 124 patients were included. For mean SSM value, there were no significant differences among 3 regions. Spleen stiffness measurement success rate in lower pole region, central region, and the region between them was 63.7% (79), 91.1% (113), and 78.2% (97), respectively. The success rate in the central region was significantly higher than that in the other 2 regions (P < 0.05). Reliability in the central region was also highest among the 3 regions. Location of stiffness measurement has a limited effect on SSM. Changing location of measurement will not influence mean stiffness value in spleen.