Philip Rauen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Philip Rauen has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Christoph Kabbasch
University Hospital Cologne, Kerpener Str 62, Cologne, 50937, Germany, 49 2214780
2 shared publications - Thorsten Persigehl
Institute of Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, 50937 Cologne, Germany
2 shared publications - Andra-Iza Iuga
Institute of Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, 50937 Cologne, Germany
1 shared publication - Carsten Gietzen
Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
1 shared publication - Grischa Bratke
Department of Radiology, University Hospital Cologne, Cologne, Germany
1 shared publication - Jan Borggrefe
Ruhr University Bochum, Germany
1 shared publication
Latest Publications
- Open Access
- 24 September 2024
- Published by Springer Nature in Clinical Neuroradiology
- Vol. 35 (1) , 105-114
Non-contrast-enhanced MR-angiography of Extracranial Arteries in Acute Ischemic Stroke at 1.5 Tesla Using Relaxation-Enhanced Angiography Without Contrast and Triggering (REACT)
Purpose: To evaluate a novel flow-independent sequence (Relaxation-Enhanced Angiography without Contrast and Triggering (REACT)) for imaging of the extracranial arteries in acute ischemic stroke (AIS) at 1.5 T. Methods: This retrospective single-center study included 47 AIS patients who received REACT (scan time: 3:01 min) and contrast-enhanced MRA (CE-MRA) of the extracranial arteries at 1.5 T in clinical routine. Two radiologists assessed scans for proximal internal carotid artery (ICA) stenosis, stated their diagnostic confidence and rated the image quality of cervical arteries, impact of artifacts and image noise. Apparent signal- and contrast-to-noise ratios (aSNR/aCNR) were measured for the common carotid artery and ICA. Results: REACT achieved a sensitivity of 95.0% and a specificity of 97.3% for ICA stenoses in high agreement with CE-MRA (κ = 0.83) with equal diagnostic confidence (p = 0.22). Image quality was rated higher for CE-MRA at the aortic arch (p = 0.002) and vertebral arteries (p < 0.001), whereas REACT provided superior results for the extracranial ICA (p = 0.008). Both sequences were only slightly affected by artifacts (p = 0.60), while image noise was more pronounced in CE-MRA (p < 0.001) in line with higher aSNR (p < 0.001) and aCNR (p < 0.001) values in REACT for all vessels. Conclusion: Given its good diagnostic performance while yielding comparable image quality and scan time to CE-MRA, REACT may be suitable for the imaging of the extracranial arteries in acute ischemic stroke at 1.5 T.
- 24 September 2024
- Published by Springer Nature in Clinical Neuroradiology
- Vol. 35 (1) , 105-114
Open AccessNon-contrast-enhanced MR-angiography of Extracranial Arteries in Acute Ischemic Stroke at 1.5 Tesla Using Relaxation-Enhanced Angiography Without Contrast and Triggering (REACT)
Purpose: To evaluate a novel flow-independent sequence (Relaxation-Enhanced Angiography without Contrast and Triggering (REACT)) for imaging of the extracranial arteries in acute ischemic stroke (AIS) at 1.5 T. Methods: This retrospective single-center study included 47 AIS patients who received REACT (scan time: 3:01 min) and contrast-enhanced MRA (CE-MRA) of the extracranial arteries at 1.5 T in clinical routine. Two radiologists assessed scans for proximal internal carotid artery (ICA) stenosis, stated their diagnostic confidence and rated the image quality of cervical arteries, impact of artifacts and image noise. Apparent signal- and contrast-to-noise ratios (aSNR/aCNR) were measured for the common carotid artery and ICA. Results: REACT achieved a sensitivity of 95.0% and a specificity of 97.3% for ICA stenoses in high agreement with CE-MRA (κ = 0.83) with equal diagnostic confidence (p = 0.22). Image quality was rated higher for CE-MRA at the aortic arch (p = 0.002) and vertebral arteries (p < 0.001), whereas REACT provided superior results for the extracranial ICA (p = 0.008). Both sequences were only slightly affected by artifacts (p = 0.60), while image noise was more pronounced in CE-MRA (p < 0.001) in line with higher aSNR (p < 0.001) and aCNR (p < 0.001) values in REACT for all vessels. Conclusion: Given its good diagnostic performance while yielding comparable image quality and scan time to CE-MRA, REACT may be suitable for the imaging of the extracranial arteries in acute ischemic stroke at 1.5 T.
- Top Cited Papers
- 1 July 2023
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 308 (1)
Feasibility of Differential Diagnosis Based on Imaging Patterns Using a Large Language Model
- 1 July 2023
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 308 (1)
Top Cited PapersFeasibility of Differential Diagnosis Based on Imaging Patterns Using a Large Language Model