Sorin Florescu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sorin Florescu has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Jenel Marian Patrascu
Orthopaedics II Research Center, “Pius Brinzeu” Emergency County Hospital, 300723 Timisoara, Romania
3 shared publications - Jenel Marian Patrascu
“Pius Brinzeu” Emergency Clinical County Hospital, Bld. Liviu Rebreanu No. 156, 300723 Timisoara, Romania
2 shared publications - Liviu-Coriolan Misca
Department of Orthopedics and Traumatology, Victor Babes University of Medicine and Pharmacy, 300041 Timisoara, Romania
2 shared publications - Adelina Mavrea
Department of Nursing, “Victor Babes” University of Medicine and Pharmacy, Eftimie Murgu Square, No. 2, 300041 Timisoara, Romania
1 shared publication - Adrian Emil Lazarescu
Department of Anatomy, Faculty of Medicine, “Victor Babeş” University of Medicine and Pharmacy, 300041 Timişoara, Romania
1 shared publication - Anca Gabriela Stoianov
Department XV, Discipline of Orthopedics-Traumatology, “Victor Babes” University of Medicine and Pharmacy, Eftimie Murgu Square, No. 2, 300041 Timisoara, Romania
1 shared publication
Latest Publications
- Open Access
- 15 September 2025
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 16 (9) , 348
Original Locking Rod System Designed for Diaphyseal Fractures of Long Bones
Introduction: Intramedullary nailing is widely used for long bone fractures. Traditional systems are reliable, but they present some complications regarding lack of modularity or possible growth plate damage. Methods: A novel locking rod–screw system featuring a central rod and a grooved screw with a secondary interlocking mechanism was developed and tested. Mechanical testing followed ASTM F543 and ISO 6475 standards using a 3.0 mm steel alloy prototype. Results: The system withstood mechanical testing >200,000 cycles at loads up to 200 N with no rates of failure or loosening, significantly outperforming other implants of the same size (3.0 mm TENS). Conclusions: The proposed implant demonstrates superior biomechanical performance in vitro, enabled by its unique hollow screw and secondary locking configuration. This modular and minimally invasive system shows promise for use in cases of smaller long bones, personalized paediatric fractures, and all types of diaphyseal fractures, but does warrant in vivo validation.
- 15 September 2025
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 16 (9) , 348
Open AccessOriginal Locking Rod System Designed for Diaphyseal Fractures of Long Bones
Introduction: Intramedullary nailing is widely used for long bone fractures. Traditional systems are reliable, but they present some complications regarding lack of modularity or possible growth plate damage. Methods: A novel locking rod–screw system featuring a central rod and a grooved screw with a secondary interlocking mechanism was developed and tested. Mechanical testing followed ASTM F543 and ISO 6475 standards using a 3.0 mm steel alloy prototype. Results: The system withstood mechanical testing >200,000 cycles at loads up to 200 N with no rates of failure or loosening, significantly outperforming other implants of the same size (3.0 mm TENS). Conclusions: The proposed implant demonstrates superior biomechanical performance in vitro, enabled by its unique hollow screw and secondary locking configuration. This modular and minimally invasive system shows promise for use in cases of smaller long bones, personalized paediatric fractures, and all types of diaphyseal fractures, but does warrant in vivo validation.
- Open Access
Sticky Bone as a New Type of Autologous Bone Grafting in Schatzker Type II Tibial Plateau Fracture Case Report
Background: Schatzker type II fractures usually need to be grafted. Autograft bone from the iliac crest represents the gold standard, but it comes with high rates of morbidity on the donor side. Sticky bone is one of the regenerative therapies that aims to find new solutions to treat bone defects and to overcome the limitation of conventional options regarding bone grafts, due to their content in growth factors, which offer osteo-induction and osteo-conduction properties. Notably, regenerative dentistry has been at the forefront of applying these products in bone regeneration, demonstrating that PRF produces a highly promising “sticky bone” when combined with bone chips. To the best of our knowledge, this grafting technique has not been used in the orthopedic field to date. Methods: The subject was a 53-year-old woman with a Schatzker type II tibial plateau fracture, for which a new autologous bone grafting technique, i.e., sticky bone, was used for the treatment of the fracture. Results: This case reports the effectiveness of sticky bone as autologous bone graft used in Shatzker type II tibial plateau fracture. As an indispensable component of regenerative medicine, it seems to be an ideal biologic graft with a fibrin-rich structure that provides effective treatment in impressed tibial plateau fractures. Conclusion: Sticky bone showed promising results and should be considered in the future as an appropriate bone implant.
Open AccessSticky Bone as a New Type of Autologous Bone Grafting in Schatzker Type II Tibial Plateau Fracture Case Report
Background: Schatzker type II fractures usually need to be grafted. Autograft bone from the iliac crest represents the gold standard, but it comes with high rates of morbidity on the donor side. Sticky bone is one of the regenerative therapies that aims to find new solutions to treat bone defects and to overcome the limitation of conventional options regarding bone grafts, due to their content in growth factors, which offer osteo-induction and osteo-conduction properties. Notably, regenerative dentistry has been at the forefront of applying these products in bone regeneration, demonstrating that PRF produces a highly promising “sticky bone” when combined with bone chips. To the best of our knowledge, this grafting technique has not been used in the orthopedic field to date. Methods: The subject was a 53-year-old woman with a Schatzker type II tibial plateau fracture, for which a new autologous bone grafting technique, i.e., sticky bone, was used for the treatment of the fracture. Results: This case reports the effectiveness of sticky bone as autologous bone graft used in Shatzker type II tibial plateau fracture. As an indispensable component of regenerative medicine, it seems to be an ideal biologic graft with a fibrin-rich structure that provides effective treatment in impressed tibial plateau fractures. Conclusion: Sticky bone showed promising results and should be considered in the future as an appropriate bone implant.
- Open Access
- 12 July 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (14) , 2352
Point-of-Care Ultrasound for the Evaluation and Management of Posterior Cruciate Ligament Injuries: A Systematic Review
Posterior cruciate ligament (PCL) injuries, though less common than other knee ligament injuries, pose significant management challenges. This study aimed to systematically review and analyze the current evidence on the use of point-of-care ultrasound (POCUS) for the evaluation and management of PCL injuries. It was hypothesized that POCUS has comparable diagnostic accuracy to magnetic resonance imaging (MRI) and that the use of POCUS improves patient outcomes and reduces healthcare costs. A comprehensive systematic review of articles published up to April 2023 was conducted using PubMed, Web of Science, Cochrane, and Scopus databases and adhered to the PRISMA guidelines. Studies were selected based on relevance to the research question, with a focus on diagnostic accuracy, reliability, clinical utility, and cost-effectiveness of POCUS in PCL injuries. Seven studies, analyzing a total of 242 patients with PCL injuries, were included. The reported sensitivity and specificity of POCUS for diagnosing PCL injuries ranged from 83.3% to 100% and 86.7% to 100%, respectively, across the studies. In one study, POCUS demonstrated a positive predictive value (PPV) of 87.9% and a negative predictive value (NPV) of 82.4%. Additionally, three studies reported 100% accuracy in PCL injury detection using POCUS, suggesting a substantial potential for cost savings by eliminating the need for MRI. This systematic review supports the use of POCUS in the evaluation and management of PCL injuries, suggesting that POCUS is a reliable, cost-effective tool with high diagnostic accuracy comparable to that of MRI, offering the potential to improve patient outcomes and reduce healthcare costs. The data collated in this review can inform clinical practice and guide future research in the field.
- 12 July 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (14) , 2352
Open AccessPoint-of-Care Ultrasound for the Evaluation and Management of Posterior Cruciate Ligament Injuries: A Systematic Review
Posterior cruciate ligament (PCL) injuries, though less common than other knee ligament injuries, pose significant management challenges. This study aimed to systematically review and analyze the current evidence on the use of point-of-care ultrasound (POCUS) for the evaluation and management of PCL injuries. It was hypothesized that POCUS has comparable diagnostic accuracy to magnetic resonance imaging (MRI) and that the use of POCUS improves patient outcomes and reduces healthcare costs. A comprehensive systematic review of articles published up to April 2023 was conducted using PubMed, Web of Science, Cochrane, and Scopus databases and adhered to the PRISMA guidelines. Studies were selected based on relevance to the research question, with a focus on diagnostic accuracy, reliability, clinical utility, and cost-effectiveness of POCUS in PCL injuries. Seven studies, analyzing a total of 242 patients with PCL injuries, were included. The reported sensitivity and specificity of POCUS for diagnosing PCL injuries ranged from 83.3% to 100% and 86.7% to 100%, respectively, across the studies. In one study, POCUS demonstrated a positive predictive value (PPV) of 87.9% and a negative predictive value (NPV) of 82.4%. Additionally, three studies reported 100% accuracy in PCL injury detection using POCUS, suggesting a substantial potential for cost savings by eliminating the need for MRI. This systematic review supports the use of POCUS in the evaluation and management of PCL injuries, suggesting that POCUS is a reliable, cost-effective tool with high diagnostic accuracy comparable to that of MRI, offering the potential to improve patient outcomes and reduce healthcare costs. The data collated in this review can inform clinical practice and guide future research in the field.