P. Svendsen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
P. Svendsen has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Finn Nielsen
Exhausto A/S, Langeskov, Denmark
1 shared publication - H. Rasmussen
Aalborg University as an Associate Professor, Department of Control and Automation
1 shared publication - Jakob Stoustrup
Department of Electronic Systems, Aalborg University, Denmark
1 shared publication - M. Komareji
PhD student, Department of Control and Automation, Institute of Electronic Systems, Aalborg University, Aalborg, Denmark
1 shared publication - N. Bidstrup
Grundfos Management A/S as a Chief Engineer, Ph.D.
1 shared publication
Latest Publications
- 1 July 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 07431619,p. 5076-5081
Optimal Set-point Synthesis in HVAC Systems
This paper presents optimal set-point synthesis for a heating, ventilating, and air-conditioning (HVAC) system. This HVAC system is made of two heat exchangers: an air-to-air heat exchanger and a water-to-air heat exchanger. The objective function is composed of the electrical power for different components, encompassing fans, primary/secondary pump, tertiary pump, and air-to-air heat exchanger wheel; and a fraction of thermal power used by the HVAC system. The goals that have to be achieved by the HVAC system appear as constraints in the optimization problem. To solve the optimization problem, a steady state model of the HVAC system is derived while different supplying hydronic circuits are studied for the water-to-air heat exchanger. Finally, the optimal set-points and the optimal supplying hydronic circuit are resulted.
- 1 July 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 07431619,p. 5076-5081
Optimal Set-point Synthesis in HVAC Systems
This paper presents optimal set-point synthesis for a heating, ventilating, and air-conditioning (HVAC) system. This HVAC system is made of two heat exchangers: an air-to-air heat exchanger and a water-to-air heat exchanger. The objective function is composed of the electrical power for different components, encompassing fans, primary/secondary pump, tertiary pump, and air-to-air heat exchanger wheel; and a fraction of thermal power used by the HVAC system. The goals that have to be achieved by the HVAC system appear as constraints in the optimization problem. To solve the optimization problem, a steady state model of the HVAC system is derived while different supplying hydronic circuits are studied for the water-to-air heat exchanger. Finally, the optimal set-points and the optimal supplying hydronic circuit are resulted.