Melih Akyuz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Melih Akyuz has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Farzan Vahedifard
Department of Diagnostic Radiology and Nuclear Medicine, Rush University Medical Center, Rush Medical College, Chicago, IL 60612, USA
3 shared publications - H. Asher Ai
Division for Diagnostic Medical Physics, Department of Radiology and Nuclear Medicine, Rush University Medical Center, Rush Medical College, Chicago, IL 60612, USA
3 shared publications - Jubril O. Adepoju
Division of Plastic and Reconstructive Surgery, Department of Surgery, Rush University Medical Center, Chicago, IL
3 shared publications - Kranthi K. Marathu
Department of Diagnostic Radiology and Nuclear Medicine, Rush University Medical Center, Rush Medical College, Chicago, IL 60612, USA
3 shared publications - Mark P. Supanich
Division for Diagnostic Medical Physics, Department of Radiology and Nuclear Medicine, Rush University Medical Center, Rush Medical College, Chicago, IL 60612, USA
3 shared publications - Mehmet Kocak
International School of Medicine, Istanbul Medipol University, 34810 Istanbul, Türkiye
3 shared publications
Latest Publications
- Open Access
- 15 July 2024
- Published by MDPI AG in Reproductive Medicine
- Vol. 5 (3) , 113-135
Fetal Gestational Age Prediction in Brain Magnetic Resonance Imaging Using Artificial Intelligence: A Comparative Study of Three Biometric Techniques
Accurately predicting a fetus’s gestational age (GA) is crucial in prenatal care. This study aimed to develop an artificial intelligence (AI) model to predict GA using biometric measurements from fetal brain magnetic resonance imaging (MRI). We assessed the significance of using different reference standards for interpreting GA predictions. Measurements of biparietal diameter (BPD), fronto-occipital diameter (FOD), and head circumference (HC) were obtained from 52 normal fetal MRI cases from Rush University. Both manual and AI-based methods were utilized, and comparisons were made using three reference standards (Garel, Freq, and Bio). The AI model showed a strong correlation with manual measurements, particularly for HC, which exhibited the highest correlation with actual values. Differences between GA predictions and picture archiving and communication system (PACS) records varied by reference, ranging from 0.47 to 2.17 weeks for BPD, 0.46 to 2.26 weeks for FOD, and 0.75 to 1.74 weeks for HC. Pearson correlation coefficients between PACS records and GA predictions exceeded 0.97 across all references. In conclusion, the AI model demonstrated high accuracy in predicting GA from fetal brain MRI measurements. This approach offers improved accuracy and convenience over manual methods, highlighting the potential of AI in enhancing prenatal care through precise GA estimation.
- 15 July 2024
- Published by MDPI AG in Reproductive Medicine
- Vol. 5 (3) , 113-135
Open AccessFetal Gestational Age Prediction in Brain Magnetic Resonance Imaging Using Artificial Intelligence: A Comparative Study of Three Biometric Techniques
Accurately predicting a fetus’s gestational age (GA) is crucial in prenatal care. This study aimed to develop an artificial intelligence (AI) model to predict GA using biometric measurements from fetal brain magnetic resonance imaging (MRI). We assessed the significance of using different reference standards for interpreting GA predictions. Measurements of biparietal diameter (BPD), fronto-occipital diameter (FOD), and head circumference (HC) were obtained from 52 normal fetal MRI cases from Rush University. Both manual and AI-based methods were utilized, and comparisons were made using three reference standards (Garel, Freq, and Bio). The AI model showed a strong correlation with manual measurements, particularly for HC, which exhibited the highest correlation with actual values. Differences between GA predictions and picture archiving and communication system (PACS) records varied by reference, ranging from 0.47 to 2.17 weeks for BPD, 0.46 to 2.26 weeks for FOD, and 0.75 to 1.74 weeks for HC. Pearson correlation coefficients between PACS records and GA predictions exceeded 0.97 across all references. In conclusion, the AI model demonstrated high accuracy in predicting GA from fetal brain MRI measurements. This approach offers improved accuracy and convenience over manual methods, highlighting the potential of AI in enhancing prenatal care through precise GA estimation.
- Open Access
- 31 July 2023
- Published by MDPI AG in Preprints.org
Artificial Intelligence Prediction of Gestational Age of Fetal in Brain Magnetic Resonance Imaging versus ultrasound Using three different Biometric Measurements
Accurately predicting a fetus's gestational age (GA) is of utmost importance in prenatal care. This study aimed to develop an artificial intelligence (AI) model that can automatically predict GA using biometric measurements derived from fetal brain mag-netic resonance imaging (MRI). Additionally, we aimed to assess the significance of con-sidering different references when interpreting GA predictions. To achieve this, we obtained measurements such as Biparietal Diameter (BPD), Fron-to-occipital Diameter (FOD), and Head Circumference (HC) from a dataset comprising 52 normal fetal MRI cases with T2 Haste sequences from Rush University. Both manual and AI-based methods were utilized to acquire these measurements. We also employed three reference papers (Garel, Freq, and Bio) for comparison purposes. The results demonstrated a strong correlation between manual and AI measure-ments, indicating consistency between the two methods. The AI-based measurement of HC exhibited a higher correlation with actual values compared to BPD, FOD, and correct-ed BPD (BPDC). When comparing these measurements with GA in the Picture Archiving and Communication System (PACS), the differences varied depending on the reference used. Specifically, the differences ranged from 0.47 to 2.17 weeks for BPD, 0.46 to 2.26 weeks for FOD, and 0.75 to 1.74 weeks for HC. Furthermore, the Pearson correlation coeffi-cient analysis revealed that all correlation coefficients between PACS records and GA pre-dictions using different references were greater than 0.97. In conclusion, the AI model based on fetal brain MRI accurately predicts GA by uti-lizing BPD, FOD, and HC measurements. The AI approach, which involves combining line segments to calculate fetal head circumference, offers improved accuracy and con-venience compared to manual estimation. This study underscores the potential of AI models in accurately estimating gestational age and highlights their utility in prenatal care. By integrating AI as a valuable tool in prenatal care, we can enhance the accuracy, ef-ficiency, and decision-making involved in assessing fetal development and monitoring pregnancies using MRI measurements.
- 31 July 2023
- Published by MDPI AG in Preprints.org
Open AccessArtificial Intelligence Prediction of Gestational Age of Fetal in Brain Magnetic Resonance Imaging versus ultrasound Using three different Biometric Measurements
Accurately predicting a fetus's gestational age (GA) is of utmost importance in prenatal care. This study aimed to develop an artificial intelligence (AI) model that can automatically predict GA using biometric measurements derived from fetal brain mag-netic resonance imaging (MRI). Additionally, we aimed to assess the significance of con-sidering different references when interpreting GA predictions. To achieve this, we obtained measurements such as Biparietal Diameter (BPD), Fron-to-occipital Diameter (FOD), and Head Circumference (HC) from a dataset comprising 52 normal fetal MRI cases with T2 Haste sequences from Rush University. Both manual and AI-based methods were utilized to acquire these measurements. We also employed three reference papers (Garel, Freq, and Bio) for comparison purposes. The results demonstrated a strong correlation between manual and AI measure-ments, indicating consistency between the two methods. The AI-based measurement of HC exhibited a higher correlation with actual values compared to BPD, FOD, and correct-ed BPD (BPDC). When comparing these measurements with GA in the Picture Archiving and Communication System (PACS), the differences varied depending on the reference used. Specifically, the differences ranged from 0.47 to 2.17 weeks for BPD, 0.46 to 2.26 weeks for FOD, and 0.75 to 1.74 weeks for HC. Furthermore, the Pearson correlation coeffi-cient analysis revealed that all correlation coefficients between PACS records and GA pre-dictions using different references were greater than 0.97. In conclusion, the AI model based on fetal brain MRI accurately predicts GA by uti-lizing BPD, FOD, and HC measurements. The AI approach, which involves combining line segments to calculate fetal head circumference, offers improved accuracy and con-venience compared to manual estimation. This study underscores the potential of AI models in accurately estimating gestational age and highlights their utility in prenatal care. By integrating AI as a valuable tool in prenatal care, we can enhance the accuracy, ef-ficiency, and decision-making involved in assessing fetal development and monitoring pregnancies using MRI measurements.
- Open Access
- 13 July 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (14) , 2355
Automatic Ventriculomegaly Detection in Fetal Brain MRI: A Step-by-Step Deep Learning Model for Novel 2D-3D Linear Measurements
In this study, we developed an automated workflow using a deep learning model (DL) to measure the lateral ventricle linearly in fetal brain MRI, which are subsequently classified into normal or ventriculomegaly, defined as a diameter wider than 10 mm at the level of the thalamus and choroid plexus. To accomplish this, we first trained a UNet-based deep learning model to segment the brain of a fetus into seven different tissue categories using a public dataset (FeTA 2022) consisting of fetal T2-weighted images. Then, an automatic workflow was developed to perform lateral ventricle measurement at the level of the thalamus and choroid plexus. The test dataset included 22 cases of normal and abnormal T2-weighted fetal brain MRIs. Measurements performed by our AI model were compared with manual measurements performed by a general radiologist and a neuroradiologist. The AI model correctly classified 95% of fetal brain MRI cases into normal or ventriculomegaly. It could measure the lateral ventricle diameter in 95% of cases with less than a 1.7 mm error. The average difference between measurements was 0.90 mm in AI vs. general radiologists and 0.82 mm in AI vs. neuroradiologists, which are comparable to the difference between the two radiologists, 0.51 mm. In addition, the AI model also enabled the researchers to create 3D-reconstructed images, which better represent real anatomy than 2D images. When a manual measurement is performed, it could also provide both the right and left ventricles in just one cut, instead of two. The measurement difference between the general radiologist and the algorithm (p = 0.9827), and between the neuroradiologist and the algorithm (p = 0.2378), was not statistically significant. In contrast, the difference between general radiologists vs. neuroradiologists was statistically significant (p = 0.0043). To the best of our knowledge, this is the first study that performs 2D linear measurement of ventriculomegaly with a 3D model based on an artificial intelligence approach. The paper presents a step-by-step approach for designing an AI model based on several radiological criteria. Overall, this study showed that AI can automatically calculate the lateral ventricle in fetal brain MRIs and accurately classify them as abnormal or normal.
- 13 July 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (14) , 2355
Open AccessAutomatic Ventriculomegaly Detection in Fetal Brain MRI: A Step-by-Step Deep Learning Model for Novel 2D-3D Linear Measurements
In this study, we developed an automated workflow using a deep learning model (DL) to measure the lateral ventricle linearly in fetal brain MRI, which are subsequently classified into normal or ventriculomegaly, defined as a diameter wider than 10 mm at the level of the thalamus and choroid plexus. To accomplish this, we first trained a UNet-based deep learning model to segment the brain of a fetus into seven different tissue categories using a public dataset (FeTA 2022) consisting of fetal T2-weighted images. Then, an automatic workflow was developed to perform lateral ventricle measurement at the level of the thalamus and choroid plexus. The test dataset included 22 cases of normal and abnormal T2-weighted fetal brain MRIs. Measurements performed by our AI model were compared with manual measurements performed by a general radiologist and a neuroradiologist. The AI model correctly classified 95% of fetal brain MRI cases into normal or ventriculomegaly. It could measure the lateral ventricle diameter in 95% of cases with less than a 1.7 mm error. The average difference between measurements was 0.90 mm in AI vs. general radiologists and 0.82 mm in AI vs. neuroradiologists, which are comparable to the difference between the two radiologists, 0.51 mm. In addition, the AI model also enabled the researchers to create 3D-reconstructed images, which better represent real anatomy than 2D images. When a manual measurement is performed, it could also provide both the right and left ventricles in just one cut, instead of two. The measurement difference between the general radiologist and the algorithm (p = 0.9827), and between the neuroradiologist and the algorithm (p = 0.2378), was not statistically significant. In contrast, the difference between general radiologists vs. neuroradiologists was statistically significant (p = 0.0043). To the best of our knowledge, this is the first study that performs 2D linear measurement of ventriculomegaly with a 3D model based on an artificial intelligence approach. The paper presents a step-by-step approach for designing an AI model based on several radiological criteria. Overall, this study showed that AI can automatically calculate the lateral ventricle in fetal brain MRIs and accurately classify them as abnormal or normal.