Sigen Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sigen Wang has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Otto Zhou
University of North Carolina at Chapel Hill 2 Department of Physics and Astronomy North Carolina 27599, USA
2 shared publicationsSha Chang
Division of Physics & Computing, Department of Radiation Oncology, University of North Carolina, Chapel Hill, NC 27599, USA
2 shared publicationsEric C. Schreiber
University of North Carolina at Chapel Hill 1 Department of Radiation Oncology North Carolina 27599, USA
1 shared publicationEric Schreiber
Department of Radiation Oncology, University of North Carolina at Chapel Hill, NC, USA
1 shared publicationErsin Ozsan
Department of Physics, School of Electronics and Physical Sciences, University of Surrey, Guildford GU2 7XH, United Kingdom
1 shared publicationJun Lian
Division of Physics & Computing, Department of Radiation Oncology, University of North Carolina, Chapel Hill, NC 27599, USA
1 shared publication
Latest Publications
- 23 May 2011
- Published by AIP Publishing in Applied Physics Letters
- Vol. 98 (21) , 213701
A carbon nanotube field emission multipixel x-ray array source for microradiotherapy application
The authors report a carbon nanotube (CNT) field emission multipixel x-ray array source for microradiotherapy for cancer research. The developed multipixel x-ray array source has 50 individually controllable pixels and it has several distinct advantages over other irradiation source including high-temporal resolution (millisecond level), the ability to electronically shape the form, and intensity distribution of the radiation fields. The x-ray array was generated by a CNT cathode array chip with electron field emission. A dose rate on the order of per x-ray pixel beam is achieved at the center of the irradiated volume. The measured dose rate is in good agreement with the Monte Carlo simulation result.- 23 May 2011
- Published by AIP Publishing in Applied Physics Letters
- Vol. 98 (21) , 213701
A carbon nanotube field emission multipixel x-ray array source for microradiotherapy application
The authors report a carbon nanotube (CNT) field emission multipixel x-ray array source for microradiotherapy for cancer research. The developed multipixel x-ray array source has 50 individually controllable pixels and it has several distinct advantages over other irradiation source including high-temporal resolution (millisecond level), the ability to electronically shape the form, and intensity distribution of the radiation fields. The x-ray array was generated by a CNT cathode array chip with electron field emission. A dose rate on the order of per x-ray pixel beam is achieved at the center of the irradiated volume. The measured dose rate is in good agreement with the Monte Carlo simulation result.- 1 February 2009
- Published by Bentham Science Publishers Ltd. in Current Nanoscience
- Vol. 5 (1) , 54-57
Improvement of Electron Field Emission in Patterned Carbon Nanotubes by High Temperature Hydrogen Plasma Treatment
In this paper, we report a significant improvement of electron field emission property in patterned carbon nanotubes films by using a high temperature (650 °C) hydrogen plasma treatment. This treatment was found to greatly increase the emission current, emission uniformity and stability. The mechanism study showed that these enhanced properties are attributed to the lowering of the potential barrier and the creation of geometrical features through the removal of amorphous carbon, catalyst particles and the saturation of dangling bonds after such a hydrogen plasma treatment.
- 1 February 2009
- Published by Bentham Science Publishers Ltd. in Current Nanoscience
- Vol. 5 (1) , 54-57
Improvement of Electron Field Emission in Patterned Carbon Nanotubes by High Temperature Hydrogen Plasma Treatment
In this paper, we report a significant improvement of electron field emission property in patterned carbon nanotubes films by using a high temperature (650 °C) hydrogen plasma treatment. This treatment was found to greatly increase the emission current, emission uniformity and stability. The mechanism study showed that these enhanced properties are attributed to the lowering of the potential barrier and the creation of geometrical features through the removal of amorphous carbon, catalyst particles and the saturation of dangling bonds after such a hydrogen plasma treatment.
- 1 January 2007
- Published by Springer Nature in MRS Proceedings
- Vol. 1065
Fabrication and Characterization of Individually Controlled Multi-Pixel Carbon Nanotube Cathode Array Chip for Micro-RT Application for Cancer Research
Carbon nanotubes (CNTs) have attracted considerable attention as future field emission electron sources for a variety of applications due to their high aspect ratio and robust structure. One application is multi-pixel beam array x-ray micro-RT (radiotherapy) for small animal irradiation. The x-ray pixel beam array is produced by a CNT pixel cathode array. One challenge in the micro-RT fabrication is how to fabricate individually addressable multi-pixel CNT cathode array on wafer with high pixel beam packing density and high emission current. We report here the development of a new CNT field emission multi-pixel cathode array chip, a vital component of the multi-pixel beam x-ray micro-RT system under development. The CNT field emission cathode array has up to 25 (5 × 5) individually addressable cathode pixels, each is 1 mm in diameter and with center-to-center distance of 2 mm. The fabrication is a two-step process: first a Cr/Cu electrical contact was fabricated on Si substrates with a 5 μm SiO2 dielectric layer using photolithography; and second the CNTs were selectively deposited on 1 mm-diameter predefined Cr/Cu contact dots by using a combined photolithography/electrophotoresis technique. The electron pixel beams produced from the multi-pixel arrays are uniform and individually controllable and can be used for micro-RT application.
- 1 January 2007
- Published by Springer Nature in MRS Proceedings
- Vol. 1065
Fabrication and Characterization of Individually Controlled Multi-Pixel Carbon Nanotube Cathode Array Chip for Micro-RT Application for Cancer Research
Carbon nanotubes (CNTs) have attracted considerable attention as future field emission electron sources for a variety of applications due to their high aspect ratio and robust structure. One application is multi-pixel beam array x-ray micro-RT (radiotherapy) for small animal irradiation. The x-ray pixel beam array is produced by a CNT pixel cathode array. One challenge in the micro-RT fabrication is how to fabricate individually addressable multi-pixel CNT cathode array on wafer with high pixel beam packing density and high emission current. We report here the development of a new CNT field emission multi-pixel cathode array chip, a vital component of the multi-pixel beam x-ray micro-RT system under development. The CNT field emission cathode array has up to 25 (5 × 5) individually addressable cathode pixels, each is 1 mm in diameter and with center-to-center distance of 2 mm. The fabrication is a two-step process: first a Cr/Cu electrical contact was fabricated on Si substrates with a 5 μm SiO2 dielectric layer using photolithography; and second the CNTs were selectively deposited on 1 mm-diameter predefined Cr/Cu contact dots by using a combined photolithography/electrophotoresis technique. The electron pixel beams produced from the multi-pixel arrays are uniform and individually controllable and can be used for micro-RT application.
- 1 January 2007
- Published by Wiley in BioFactors
- Vol. 30 (4) , 265-270
A novel high resolution micro‐radiotherapy system for small animal irradiation for cancer research
Micro‐radiotherapy (micro‐RT) system is specially designed for small animal (cancer cell) irradiation for basic and translational cancer research. We use carbon nanotube (CNT) field emission technology to develop a novel micro‐RT system for image‐guided high precision irradiation that is similar to the state of the art radiotherapy which our cancer patients receive today at mouse scale. Through the field emission control of its individually addressable x‐ray pixel beams the micro‐RT system electronically shapes the radiation field and forms intensity modulation pattern. In this paper, we present the development of a carbon nanotube field emission cathode array chip — a key component for our novel micro‐RT system. The prototype micro‐RT CNT field emission cathode array chip has 5×5 individually addressable cathode pixels that are 1 mm in diameter and 2 mm in pitch. An individual CNT cathode pixel is predicted to generate a dose rate in the order of 100 cGy/min at the center of the irradiated mouse based on our Monte Carlo simulation. The temporal and spatial resolutions of the micro‐RT system are expected to be ∼ms level and <2 mm respectively.
- 1 January 2007
- Published by Wiley in BioFactors
- Vol. 30 (4) , 265-270
A novel high resolution micro‐radiotherapy system for small animal irradiation for cancer research
Micro‐radiotherapy (micro‐RT) system is specially designed for small animal (cancer cell) irradiation for basic and translational cancer research. We use carbon nanotube (CNT) field emission technology to develop a novel micro‐RT system for image‐guided high precision irradiation that is similar to the state of the art radiotherapy which our cancer patients receive today at mouse scale. Through the field emission control of its individually addressable x‐ray pixel beams the micro‐RT system electronically shapes the radiation field and forms intensity modulation pattern. In this paper, we present the development of a carbon nanotube field emission cathode array chip — a key component for our novel micro‐RT system. The prototype micro‐RT CNT field emission cathode array chip has 5×5 individually addressable cathode pixels that are 1 mm in diameter and 2 mm in pitch. An individual CNT cathode pixel is predicted to generate a dose rate in the order of 100 cGy/min at the center of the irradiated mouse based on our Monte Carlo simulation. The temporal and spatial resolutions of the micro‐RT system are expected to be ∼ms level and <2 mm respectively.