Setianto Samingan Agus
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Setianto Samingan Agus has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Tom Schanz
Bauhaus-Universität Weimar
3 shared publications - Yulian Firmana Arifin
University of Lambung Mangkurat
1 shared publication
Latest Publications
- 17 March 2006
- Published by American Society of Civil Engineers (ASCE)
- p. 1405-1414
Drying, Wetting, and Suction Characteristic Curves of a Bentonite-Sand Mixture
The objective of the paper is to compare drying, wetting, and suction characteristic curves of a bentonite-sand mixture. A mixture, of 50 percent bentonite and 50 percent sand was prepared and used in this investigation. The main drying curve of the mixture was determined for a slurried specimen of the mixture using a chilled-mirror hygrometer. Several drying and wetting tests were also performed on the compacted mixture with an initial water content of about 9 percent and initial dry density of about 2 Mg/m3 incorporating different suction paths using a desiccator and a pressure plate apparatus. The suction characteristic curve for the mixture was obtained at loose as well as compacted states by utilizing the chilled-mirror hygrometer. The experimental results obtained are presented and compared. The drying, wetting, and suction characteristic curves of the material are different. Factors causing the differences including suction paths, hysteresis, and fabric effects are also discussed in this paper.
- 17 March 2006
- Published by American Society of Civil Engineers (ASCE)
- p. 1405-1414
Drying, Wetting, and Suction Characteristic Curves of a Bentonite-Sand Mixture
The objective of the paper is to compare drying, wetting, and suction characteristic curves of a bentonite-sand mixture. A mixture, of 50 percent bentonite and 50 percent sand was prepared and used in this investigation. The main drying curve of the mixture was determined for a slurried specimen of the mixture using a chilled-mirror hygrometer. Several drying and wetting tests were also performed on the compacted mixture with an initial water content of about 9 percent and initial dry density of about 2 Mg/m3 incorporating different suction paths using a desiccator and a pressure plate apparatus. The suction characteristic curve for the mixture was obtained at loose as well as compacted states by utilizing the chilled-mirror hygrometer. The experimental results obtained are presented and compared. The drying, wetting, and suction characteristic curves of the material are different. Factors causing the differences including suction paths, hysteresis, and fabric effects are also discussed in this paper.
- 17 March 2006
- Published by American Society of Civil Engineers (ASCE)
- p. 1314-1325
Temperature Effects on Suction Characteristic Curve of Bentonite-Sand Mixtures
This study focused on the effects of temperature on the suction characteristic curve of bentonite-sand mixtures. Mixtures of bentonite (Calcigel) and quartz sand were used. Three different suction measurement methods (i.e., chilled-mirror hygrometer, non warmed-capacitance sensor, and warmed-head capacitance sensors) were used for measuring total suction. A special device was developed to maintain the specimen conditions during test at a temperature up to 80 degrees C. The procedures adopted in the study are described in this paper. The total suction of the specimens measured by the different methods both at 20 degrees C and 80 degrees C are compared. Factors affecting the alteration of suction due to temperature change are discussed in the paper.
- 17 March 2006
- Published by American Society of Civil Engineers (ASCE)
- p. 1314-1325
Temperature Effects on Suction Characteristic Curve of Bentonite-Sand Mixtures
This study focused on the effects of temperature on the suction characteristic curve of bentonite-sand mixtures. Mixtures of bentonite (Calcigel) and quartz sand were used. Three different suction measurement methods (i.e., chilled-mirror hygrometer, non warmed-capacitance sensor, and warmed-head capacitance sensors) were used for measuring total suction. A special device was developed to maintain the specimen conditions during test at a temperature up to 80 degrees C. The procedures adopted in the study are described in this paper. The total suction of the specimens measured by the different methods both at 20 degrees C and 80 degrees C are compared. Factors affecting the alteration of suction due to temperature change are discussed in the paper.