Annarita Tedesco
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Annarita Tedesco has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Alfonso Maria Ponsiglione
Department of Electrical Engineering and Information Technology, University of Naples Federico II, 80125 Naples, Italy
2 shared publications - Carlo Cosentino
School of Computer and Biomedical Engineering, Dipartimento di Medicina Sperimentale e Clinica, Universit degli Studi Magna Grcia di Catanzaro, Catanzaro, Italy
2 shared publications - Francesco Amato
Department of Information Technology and Electrical Engineering, University of Naples Federico II, 80125 Naples, Italy
2 shared publications - Maria Romano
Department of Electrical Engineering and Information Technology, University of Naples Federico II, 80125 Naples, Italy
2 shared publications - Alessio Merola
Department of Experimental and Clinical Medicine Magna Græcia University of Catanzaro Catanzaro Italy
1 shared publication - Carlo Ricciardi
Department of Electrical Engineering and Information Technology, University of Naples Federico II, 80125 Naples, Italy
1 shared publication
Latest Publications
- Open Access
- 14 July 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (7) , 835
A General Approach for the Modelling of Negative Feedback Physiological Control Systems
Mathematical models can improve the understanding of physiological systems behaviour, which is a fundamental topic in the bioengineering field. Having a reliable model enables researchers to carry out in silico experiments, which require less time and resources compared to their in vivo and in vitro counterparts. This work’s objective is to capture the characteristics that a nonlinear dynamical mathematical model should exhibit, in order to describe physiological control systems at different scales. The similarities among various negative feedback physiological systems have been investigated and a unique general framework to describe them has been proposed. Within such a framework, both the existence and stability of equilibrium points are investigated. The model here introduced is based on a closed-loop topology, on which the homeostatic process is based. Finally, to validate the model, three paradigmatic examples of physiological control systems are illustrated and discussed: the ultrasensitivity mechanism for achieving homeostasis in biomolecular circuits, the blood glucose regulation, and the neuromuscular reflex arc (also referred to as muscle stretch reflex). The results show that, by a suitable choice of the modelling functions, the dynamic evolution of the systems under study can be described through the proposed general nonlinear model. Furthermore, the analysis of the equilibrium points and dynamics of the above-mentioned systems are consistent with the literature.
- 14 July 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (7) , 835
Open AccessA General Approach for the Modelling of Negative Feedback Physiological Control Systems
Mathematical models can improve the understanding of physiological systems behaviour, which is a fundamental topic in the bioengineering field. Having a reliable model enables researchers to carry out in silico experiments, which require less time and resources compared to their in vivo and in vitro counterparts. This work’s objective is to capture the characteristics that a nonlinear dynamical mathematical model should exhibit, in order to describe physiological control systems at different scales. The similarities among various negative feedback physiological systems have been investigated and a unique general framework to describe them has been proposed. Within such a framework, both the existence and stability of equilibrium points are investigated. The model here introduced is based on a closed-loop topology, on which the homeostatic process is based. Finally, to validate the model, three paradigmatic examples of physiological control systems are illustrated and discussed: the ultrasensitivity mechanism for achieving homeostasis in biomolecular circuits, the blood glucose regulation, and the neuromuscular reflex arc (also referred to as muscle stretch reflex). The results show that, by a suitable choice of the modelling functions, the dynamic evolution of the systems under study can be described through the proposed general nonlinear model. Furthermore, the analysis of the equilibrium points and dynamics of the above-mentioned systems are consistent with the literature.
- Open Access
- 15 February 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (2) , 252
Detection of Suspicious Cardiotocographic Recordings by Means of a Machine Learning Classifier
Cardiotocography (CTG) is one of the fundamental prenatal diagnostic methods for both antepartum and intrapartum fetal surveillance. Although it has allowed a significant reduction in intrapartum and neonatal mortality and morbidity, its diagnostic accuracy is, however, still far from being fully satisfactory. In particular, the identification of uncertain and suspicious CTG traces remains a challenging task for gynecologists. The introduction of computerized analysis systems has enabled more objective evaluations, possibly leading to more accurate diagnoses. In this work, the problem of classifying suspicious CTG recordings was addressed through a machine learning approach. A machine-based labeling was proposed, and a binary classification was carried out using a support vector machine (SVM) classifier to distinguish between suspicious and normal CTG traces. The best classification metrics showed accuracy, sensitivity, and specificity values of 92%, 92%, and 90%, respectively. The main results were compared both with results obtained by considering a more unbalanced dataset and with relevant literature studies in the field. The use of the SVM proved to be promising in the field of CTG classification. However, appropriate feature selection and dataset balancing are crucial to achieve satisfactory performance of the classifier.
- 15 February 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (2) , 252
Open AccessDetection of Suspicious Cardiotocographic Recordings by Means of a Machine Learning Classifier
Cardiotocography (CTG) is one of the fundamental prenatal diagnostic methods for both antepartum and intrapartum fetal surveillance. Although it has allowed a significant reduction in intrapartum and neonatal mortality and morbidity, its diagnostic accuracy is, however, still far from being fully satisfactory. In particular, the identification of uncertain and suspicious CTG traces remains a challenging task for gynecologists. The introduction of computerized analysis systems has enabled more objective evaluations, possibly leading to more accurate diagnoses. In this work, the problem of classifying suspicious CTG recordings was addressed through a machine learning approach. A machine-based labeling was proposed, and a binary classification was carried out using a support vector machine (SVM) classifier to distinguish between suspicious and normal CTG traces. The best classification metrics showed accuracy, sensitivity, and specificity values of 92%, 92%, and 90%, respectively. The main results were compared both with results obtained by considering a more unbalanced dataset and with relevant literature studies in the field. The use of the SVM proved to be promising in the field of CTG classification. However, appropriate feature selection and dataset balancing are crucial to achieve satisfactory performance of the classifier.