JWJanus A. C. Wartmann

Janus A. C. Wartmann

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Janus A. C. Wartmann has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Near‐Infrared Imaging of H 2 O 2 in Plants With Nanosensors Under Environmentally Changing Conditions

    by Jiaqi Li, Bjoern F. Hill, Chen Ma, Juliana Gretz, Tanuja Kistwal, Janus A. C. Wartmann, Justus T. Metternich, Juan Pablo Giraldo, Sebastian Kruss

    Optical sensors are powerful tools to monitor biological systems. However, their practical deployment is often limited by environmental interferences such as autofluorescence, mechanical motion, and fluctuating illumination. These challenges are particularly pronounced in plants because they require and use light, which has impaired the use of (fluorescent) sensors for plant stress signals such as H 2 O 2 . Here, we present a ratiometric sensing platform that overcomes these limitations by integrating three spectrally distinct components: 1) an H 2 O 2 sensor based on aptamer modified near infrared (NIR) fluorescent single walled carbon nanotubes (SWCNTs, ∼1000 nm), 2) a stable NIR reference based on polyethyleneglycol modified Egyptian Blue nanosheets (EB–NS, 900–955 nm) and 3) a visible (VIS) signal (∼641 nm) to correct for the NIR autofluorescence tail of plants (>835 nm). This ratiometric approach enables robust signal correction under relevant perturbations, including leaf rotation and wind‐induced motion. Furthermore, it allows continuous H 2 O 2 monitoring under dynamically varying illumination conditions (>300%), resulting in a 75% enhancement in signal contrast compared to single‐channel detection. By spectrally resolving nanosensor signals and endogenous plant autofluorescence, this strategy enables in vivo monitoring of stress‐induced H 2 O 2 under realistic environmental conditions. It establishes interference‐resistant optical sensing and advances field‐deployable nanosensor technologies for precision agriculture.

  • Open Access

    High‐Efficiency Quantum Defect Generation in Carbon Nanotubes via Oxygen‐Free Photochemistry

    by Christina Derichsweiler, Valeriia D. Andreeva, Jan Stegemann, Julia Ackermann, Janus A. C. Wartmann, Svenja Herbertz, Sebastian Kruss

    Single‐walled carbon nanotubes (SWCNTs) offer potential for a wide range of applications from optoelectronic devices to biomedical diagnostics. One reason is their tunable optical properties, which can be tailored by introducing quantum defects. However, the chemical conditions to obtain an optimal number and specific type of quantum defect are difficult to control. Here, we demonstrate that oxygen‐free conditions are crucial to control the spectral features. To this end, we analyze the photochemical reaction of (6,5)‐SWCNTs with different alkyl/aryl halides and alkenyl/alkynyl compounds under UV irradiation. Removal of oxygen or addition of sulfites shifts the quantum defect‐related E 11 * emission peak from ∼1130 to ∼1100 nm, suggesting that different types of quantum defects are formed. For aryl halides, these conditions increase the E 11 */E 11 ratio up to 90%, while reducing the required reactant concentration by ∼90%, with reaction times < 10 min. For the less reactive alkyl halide, ∼80‐fold smaller reactant concentrations yielded similar E 11 */E 11 ratios compared to oxygen‐containing conditions. This allows us to investigate the combined effect of quantum defects and DNA functionalization of SWCNTs on small‐molecule detection. It underlines that efficient incorporation of quantum defects opens a new chemical dimension for SWCNT chemistry and enables control of fluorescence properties.

  • Open Access

    One‐Pot Incorporation of Quantum Defects into Single‐Walled Carbon Nanotubes with Arylazo Sulfonates

    by Valeriia D. Andreeva, Justus T. Metternich, Chen Ma, Janus A.C. Wartmann, Sebastian Kruss

    Single‐walled carbon nanotubes (SWCNTs) consist of a carbon monolayer and fluoresce in the near‐infrared (NIR, 800–2500 nm) region. Introduction of sp 3 quantum defects (QDs) creates novel NIR emission features, which promise huge potential for (bio)photonics. However, so far defect chemistry based on diazonium salts is mainly limited to benzene derivatives. The reaction side products also quench SWCNT fluorescence and impair additional surface chemistry. Here, we introduce a photochemical strategy based on arylazo sulfonates to a) create more complex aromatic QDs and b) avoid side products that adsorb and quench. We show that this way coumarin and other QDs are incorporated, which increases overall NIR emission by more than 90% without purification. These materials can be non‐covalently modified with biocompatible polymers (polyethyleneglycoles, DNA) without a change in photophysical properties and we demonstrate mechanical (viscosity) and chemical (neurotransmitter dopamine) sensing. This one‐pot approach creates QDs in SWCNTs and provides access to advanced hybrid materials for photonic applications.

  • Open Access

    One‐Pot Incorporation of Quantum Defects into Single‐Walled Carbon Nanotubes with Arylazo Sulfonates

    by Valeriia D. Andreeva, Justus T. Metternich, Chen Ma, Janus A.C. Wartmann, Sebastian Kruss

    Single‐walled carbon nanotubes (SWCNTs) consist of a carbon monolayer and fluoresce in the near‐infrared (NIR, 800–2500 nm) region. Introduction of sp 3 quantum defects (QDs) creates novel NIR emission features, which promise huge potential for (bio)photonics. However, so far defect chemistry based on diazonium salts is mainly limited to benzene derivatives. The reaction side products also quench SWCNT fluorescence and impair additional surface chemistry. Here, we introduce a photochemical strategy based on arylazo sulfonates to a) create more complex aromatic QDs and b) avoid side products that adsorb and quench. We show that this way coumarin and other QDs are incorporated, which increases overall NIR emission by more than 90% without purification. These materials can be non‐covalently modified with biocompatible polymers (polyethyleneglycoles, DNA) without a change in photophysical properties and we demonstrate mechanical (viscosity) and chemical (neurotransmitter dopamine) sensing. This one‐pot approach creates QDs in SWCNTs and provides access to advanced hybrid materials for photonic applications.


  • Open Access

    A Near Infrared Emission Feature from Visible Fluorescence Tails and its Correlation with Singlet Oxygen

    by Bjoern F. Hill, Jiaqi Li, Norman Labedzki, Christina Derichsweiler, Janus A. C. Wartmann, Krisztian Neutsch, Luise Erpenbeck, Sebastian Kruss

    The near infrared (NIR, >800 nm) or short wave infrared (SWIR) range of the electromagnetic spectrum overlays with the tissue transparency window and the telecommunication window, which makes it important for photonics. Here, a persistent NIR tail and a feature at 923 nm is observed during the photochemical generation of singlet oxygen using various photosensitizers. This feature initially appears to originate from singlet oxygen as its energy fits to known higher order optical and vibrational transitions, and it occurs simultaneously with the characteristic singlet oxygen phosphorescence at 1275 nm. The emission is present under all photochemical conditions (photosensitizers, solvents, excitation sources and optical setups) but it is not observed for chemically generated singlet oxygen. Its intensity correlates with photosensitizer concentration (1 µM – 1 mM), excitation intensity, and the visible fluorescence intensity, but does not require the presence of oxygen. A simulation shows that this feature arises from the NIR‐tail of (visible) photosensitizer emission and the non‐linear increase of detector sensitivities in the range between 900– 950 nm. At the same time, this signal correlates with photochemically generated singlet oxygen concentration. Thus, this NIR signal contains valuable information, but careful interpretation is required.


  • Open Access

    Signalverstärkung und Nah‐Infrarot Übersetzung von Enzymatischen Reaktionen mit Nanosensoren**

    by Justus T. Metternich, Björn Hill, Janus A. C. Wartmann, Chen Ma, Rebecca M. Kruskop, Krisztian Neutsch, Svenja Herbertz, Sebastian Kruss

    Enzymatische Reaktionen kommen in zahlreichen biochemischen Verfahren zum Nachweis von Analyten zum Einsatz. Um das Vorhandensein eines Analyten zu messen, werden die Enzyme an eine Erkennungseinheit konjugiert und wandeln ein Substrat in ein (farbiges) Produkt um, das im sichtbaren Bereich (VIS) des Spektrums nachgewiesen werden kann. Der niedrigste nachweisbare enzymatische Umsatz stellt somit eine Grenze für die Empfindlichkeit dar. Hier zeigen wir, dass Substrate und Produkte der Meerrettichperoxidase (HRP) und der β‐Galaktosidase die Fluoreszenz im nahen Infrarot (NIR) von einwandigen Kohlenstoffnanoröhren (SWCNTs) verändern, wenn diese mit (Bio−)Polymeren modifiziert sind. Durch die Fluoreszenz im NIR übersetzen die SWCNTs ein VIS‐Signal in ein NIR‐Signal. Zudem führt die Affinität der Nanosensoren zu einer höheren effektiven lokalen Konzentration der Reaktanten. Dies bewirkt eine nichtlineare sensorbasierte Signalverstärkung und ‐übersetzung (SENSAT). Für das HRP‐Substrat p‐Phenylendiamin (PPD) ergibt sich eine bis zu ≈120‐fache Signalverstärkung, die es erlaubt, Reaktionen unterhalb der VIS Nachweisgrenze im NIR (≈1000 nm) zu verfolgen. Der Ansatz ist auch auf andere Substrate wie 3,3‐5,5′‐Tetramethylbenzidin (TMB) anwendbar. Ein Adsorptionsmodell erklärt die beobachteten Signaländerung und bestätigt den Verstärkungsmechanismus. Mit Hilfe dieses Ansatzes lassen sich Signale von chromogenen enzymatischen Reaktionsprodukten verstärken, in den NIR‐Bereich übertragen und die Empfindlichkeit biochemischer Assays erhöhen.

  • Open Access

    Signal Amplification and Near‐Infrared Translation of Enzymatic Reactions by Nanosensors**

    by Justus T. Metternich, Björn Hill, Janus A. C. Wartmann, Chen Ma, Rebecca M. Kruskop, Krisztian Neutsch, Svenja Herbertz, Sebastian Kruss

    Enzymatic reactions are used to detect analytes in a range of biochemical methods. To measure the presence of an analyte, the enzyme is conjugated to a recognition unit and converts a substrate into a (colored) product that is detectable by visible (VIS) light. Thus, the lowest enzymatic turnover that can be detected sets a limit on sensitivity. Here, we report that substrates and products of horseradish peroxidase (HRP) and β‐galactosidase change the near‐infrared (NIR) fluorescence of (bio)polymer modified single‐walled carbon nanotubes (SWCNTs). They translate a VIS signal into a beneficial NIR signal. Moreover, the affinity of the nanosensors leads to a higher effective local concentration of the reactants. This causes a non‐linear sensor‐based signal amplification and translation (SENSAT). We find signal enhancement up to ≈120x for the HRP substrate p‐phenylenediamine (PPD), which means that reactions below the limit of detection in the VIS can be followed in the NIR (≈1000 nm). The approach is also applicable to other substrates such as 3,3′‐5,5′‐tetramethylbenzidine (TMB). An adsorption‐based theoretical model fits the observed signals and corroborates the sensor‐based enhancement mechanism. This approach can be used to amplify signals, translate them into the NIR and increase sensitivity of biochemical assays.


  • Near-Infrared Fluorescent Biosensors Based on Covalent DNA Anchors

    by Justus T. Metternich, Janus A. C. Wartmann, Linda Sistemich, Robert Nißler, Svenja Herbertz, Sebastian Kruss

    Semiconducting single-walled carbon nanotubes (SWCNTs) are versatile near-infrared (NIR) fluorophores. They are noncovalently modified to create sensors that change their fluorescence when interacting with biomolecules. However, noncovalent chemistry has several limitations and prevents a consistent way to molecular recognition and reliable signal transduction. Here, we introduce a widely applicable covalent approach to create molecular sensors without impairing the fluorescence in the NIR (>1000 nm). For this purpose, we attach single-stranded DNA (ssDNA) via guanine quantum defects as anchors to the SWCNT surface. A connected sequence without guanines acts as flexible capture probe allowing hybridization with complementary nucleic acids. Hybridization modulates the SWCNT fluorescence and the magnitude increases with the length of the capture sequence (20 > 10 ≫ 6 bases). The incorporation of additional recognition units via this sequence enables a generic route to NIR fluorescent biosensors with improved stability. To demonstrate the potential, we design sensors for bacterial siderophores and the SARS CoV-2 spike protein. In summary, we introduce covalent guanine quantum defect chemistry as rational design concept for biosensors.