Jun Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jun Zhang has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Xinjian Feng
State Key Laboratory of Bioinspired Interfacial Materials Science, College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou 215123, China
3 shared publications Haili Wang
College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou, China
2 shared publicationsYangru Chen
College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou, China
2 shared publicationsDandan Wang
College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou, 215123, PR China
1 shared publication- Haili Wang
College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou 215000, China
1 shared publication Jiahui Fan
Hangzhou Institute of Advanced Studies, Zhejiang Normal University, 1108 Gengwen Road, Hangzhou 311231, China
1 shared publication
Latest Publications
- 20 July 2023
- Published by Royal Society of Chemistry (RSC) in Dalton Transactions
- Vol. 52 (33) , 11571-11580
A solid-state synthetic strategy toward nickel-based bimetallic interstitial compounds (MNi3Cx, M = Zn, In, Ga)
A novel solid-state synthetic strategy toward nickel-based bimetallic interstitial compounds (MNi3Cx, M = Zn, In, and Ga) was developed.
- 20 July 2023
- Published by Royal Society of Chemistry (RSC) in Dalton Transactions
- Vol. 52 (33) , 11571-11580
A solid-state synthetic strategy toward nickel-based bimetallic interstitial compounds (MNi3Cx, M = Zn, In, Ga)
A novel solid-state synthetic strategy toward nickel-based bimetallic interstitial compounds (MNi3Cx, M = Zn, In, and Ga) was developed.
- Open Access
- 8 January 2023
- Published by MDPI AG in Biomimetics
- Vol. 8 (1) , 26
Laser-Induced Graphene Arrays-Based Three-Phase Interface Enzyme Electrode for Reliable Bioassays
Electrochemical oxidase biosensors have been widely applied in healthcare, environmental measurements and the biomedical field. However, the low and fluctuant oxygen levels in solution and the high anodic detection potentially restrict the assay accuracy. To address these problems, in this work, we constructed a three-phase interface enzyme electrode by sequentially immobilizing H2O2 electrocatalysts and an oxidase layer on a superhydrophobic laser-induced graphene (LIG) array substrate. The LIG-based enzyme electrode possesses a solid–liquid–air three-phase interface where constant and sufficient oxygen can be supplied from the air phase to the enzymatic reaction zone, which enhances and stabilizes the oxidase kinetics. We discovered that the enzymatic reaction rate is 21.2-fold improved over that of a solid–liquid diphase system where oxygen is supplied from the liquid phase, leading to a 60-times wider linear detection range. Moreover, the three-phase enzyme electrode can employ a cathodic measuring principle for oxidase catalytic product H2O2 detection, which could minimize interferences arising from oxidizable molecules in biofluids and increase the detection selectivity. This work provides a simple and promising approach to the design and construction of high-performance bioassay systems.
- 8 January 2023
- Published by MDPI AG in Biomimetics
- Vol. 8 (1) , 26
Open AccessLaser-Induced Graphene Arrays-Based Three-Phase Interface Enzyme Electrode for Reliable Bioassays
Electrochemical oxidase biosensors have been widely applied in healthcare, environmental measurements and the biomedical field. However, the low and fluctuant oxygen levels in solution and the high anodic detection potentially restrict the assay accuracy. To address these problems, in this work, we constructed a three-phase interface enzyme electrode by sequentially immobilizing H2O2 electrocatalysts and an oxidase layer on a superhydrophobic laser-induced graphene (LIG) array substrate. The LIG-based enzyme electrode possesses a solid–liquid–air three-phase interface where constant and sufficient oxygen can be supplied from the air phase to the enzymatic reaction zone, which enhances and stabilizes the oxidase kinetics. We discovered that the enzymatic reaction rate is 21.2-fold improved over that of a solid–liquid diphase system where oxygen is supplied from the liquid phase, leading to a 60-times wider linear detection range. Moreover, the three-phase enzyme electrode can employ a cathodic measuring principle for oxidase catalytic product H2O2 detection, which could minimize interferences arising from oxidizable molecules in biofluids and increase the detection selectivity. This work provides a simple and promising approach to the design and construction of high-performance bioassay systems.
- Open Access
- 28 April 2022
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 10, 909187
Three-Phases Interface Induced Local Alkalinity Generation Enables Electrocatalytic Glucose Oxidation in Neutral Electrolyte
Electrocatalytic glucose oxidation is crucial to the development of non-enzymatic sensors, an attractive alternative for enzymatic biosensors. However, due to OH− consumption during the catalytic process, non-enzymatic detection generally requires electrolytes having an alkaline pH value, limiting its practical application since biofluids are neutral. Herein, via interfacial microenvironment design, we addressed this limitation by developing a non-enzymatic sensor with an air–solid–liquid triphase interface electrodes that synergistically integrates the functions of local alkalinity generation and electrocatalytic glucose oxidation. A sufficiently high local pH value was achieved via oxygen reduction reaction at the triphase interface, which consequently enabled the electrochemical oxidation (detection) of glucose in neutral solution. Moreover, we found that the linear detection range and sensitivity of triphase non-enzymatic sensor can be tuned by changing the electrocatalysts of the detection electrode. The triphase electrode architecture provides a new platform for further exploration and promotes practical application of non-enzymatic sensors.
- 28 April 2022
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 10, 909187
Open AccessThree-Phases Interface Induced Local Alkalinity Generation Enables Electrocatalytic Glucose Oxidation in Neutral Electrolyte
Electrocatalytic glucose oxidation is crucial to the development of non-enzymatic sensors, an attractive alternative for enzymatic biosensors. However, due to OH− consumption during the catalytic process, non-enzymatic detection generally requires electrolytes having an alkaline pH value, limiting its practical application since biofluids are neutral. Herein, via interfacial microenvironment design, we addressed this limitation by developing a non-enzymatic sensor with an air–solid–liquid triphase interface electrodes that synergistically integrates the functions of local alkalinity generation and electrocatalytic glucose oxidation. A sufficiently high local pH value was achieved via oxygen reduction reaction at the triphase interface, which consequently enabled the electrochemical oxidation (detection) of glucose in neutral solution. Moreover, we found that the linear detection range and sensitivity of triphase non-enzymatic sensor can be tuned by changing the electrocatalysts of the detection electrode. The triphase electrode architecture provides a new platform for further exploration and promotes practical application of non-enzymatic sensors.
- 1 July 2021
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 183, 113201
Flexible triphase enzyme electrode based on hydrophobic porous PVDF membrane for high-performance bioassays
- 1 July 2021
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 183, 113201
Flexible triphase enzyme electrode based on hydrophobic porous PVDF membrane for high-performance bioassays