KMKosuke Matsuda

Kosuke Matsuda

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kosuke Matsuda has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Optimizing arm placement in the Hugo™ RAS system-based hysterectomy: development and validation of a simplified “Narrow setting” approach

    by Takahiro Nozaki, Keiko Kagami, Eriko Kawataki, Mitsunori Uchida, Kosuke Matsuda, Ikuko Sakamoto

    We aimed to determine the usefulness of the new setup, the “Narrow setting,” by examining our initial experience with the Hugo™ RAS system. 78 hysterectomies using the Hugo™ RAS system performed in "Narrow setting" at our institution from November 2023 to December 2024 were included in this study. We retrospectively examined the patient's clinical information and surgical outcomes from the medical record. We also investigated the learning curve of docking time in this setting by cumulative summation analysis. The median age, body mass index, and uterine weight of the patients were 48 (31–76) years, 22.9 kg/m2 (16.1–42.4), and 178 g (40–2000 g), respectively. More than half of the surgical indications were uterine myomas (52.6%, 41/78). The median operative, console, and docking times were 68 min (48–198 min), 46 min (29–151 min), and 9 min (6–31 min), respectively. The median estimated blood loss was 5 mL (5–220 mL). A total of eight perioperative complications were observed, but only one was classified as Clavien–Dindo grade III or higher. No conversion to open or laparoscopic surgery was required. The learning curve for docking time showed that docking in the “Narrow setting” can be proficient in 19 cases. We reported on our initial experience with hysterectomy using the Hugo™ RAS system and found the “Narrow setting” to be safe and efficient.


  • Surgical Outcomes of Multiple Robot‐Assisted Hysterectomies in a Single Workday by the Same Surgeon

    by Takahiro Nozaki, Kosuke Matsuda, Ayaka Hosaka, Yoshihiko Ito, Keiko Kagami, Ikuko Sakamoto

    Introduction: Due to the growing medical need for gynecologic robotic surgery, several robotic surgeries may be performed in a single day at high‐volume centers. This study evaluated the safety of performing multiple robot‐assisted hysterectomies (RAHs) per day by the same surgeon. Methods: We reviewed the clinical data of patients who underwent robotic surgery from April 2018 to September 2024 at the Department of Gynecology, Yamanashi Central Hospital, and also examined the surgical type, order, and surgeon for each procedure. Results: A total of 352 RAHs performed by the same surgeon were included. Among them, 267 were the first and second cases performed on the same day (Group A), and 85 were the third to fifth cases (Group B). There were no statistically significant differences between the two groups regarding age, body mass index, uterine weight, surgical indication, and history of abdominal surgery. The median operative time of 68 (35–179) min in Group A and 66 (37–187) min in Group B was similar ( p = 0.141). Both groups also had similar estimated blood loss ( p = 0.744). Each group had two perioperative complications, and no patient underwent conversion to open or laparoscopic surgery. Conclusion: Performing multiple RAHs by the same surgeon in a single day may be a safe procedure with no negative impact on operative time, blood loss, or perioperative complications. Hence, it could be a useful treatment option for high‐volume centers.


  • Does the presence of abdominal wall adhesions make gynecologic robotic surgery difficult?

    by Takahiro Nozaki, Kosuke Matsuda, Keiko Kagami, Ikuko Sakamoto

    This study aimed to assess the status of abdominal wall adhesions resulting from prior surgeries and their impact on the outcomes of robotic surgery. We retrospectively reviewed clinical information, surgical outcomes, and the status of abdominal wall adhesions in patients who underwent gynecologic robotic surgery at Yamanashi Central Hospital, between April 2018 and March 2023. Abdominal wall adhesions were classified into seven locations and their presence was assessed at each site. Among the 768 cases examined, 196 showed the presence of abdominal wall adhesions. Notably, patients with a history of abdominal surgery exhibited a significantly higher incidence of abdominal wall adhesions than those without such surgical history, although no significant difference was observed in the frequency of adhesions in the upper left abdomen. Patients with a history of gynecologic, gastrointestinal, or biliopancreatic surgeries were more likely to have adhesions at the umbilicus or upper abdomen sites where trocars are typically inserted during robotic surgery. Although cases with abdominal wall adhesions experienced longer operative times than those without, there was no significant difference in estimated blood loss. In 13 cases (1.7%), adjustments in trocar placement were necessary due to abdominal wall adhesions, although none of the cases required conversion to open or conventional laparoscopic surgery. Abdominal wall adhesions pose challenges to minimally invasive procedures, emphasizing the importance of predicting these adhesions based on a patient’s surgical history to safely perform robotic surgery. These results suggest that the robot’s flexibility proves effective in managing abdominal wall adhesions.


  • Comparison of surgical outcomes between robot-assisted and conventional laparoscopic hysterectomy for large uterus

    by Takahiro Nozaki, Kosuke Matsuda, Keiko Kagami, Ikuko Sakamoto

    We compared the effectiveness of conventional total laparoscopic hysterectomy (TLH) against robot-assisted total hysterectomy (RAH) in patients with a large uterus. According to the subtype of minimally invasive hysterectomy performed for benign indications, the patients (n = 843) were grouped as follows: TLH (n = 340) and RAH (n = 503). The median operative time (OT) for TLH was 98 min (47–406 min), and the estimated blood loss (EBL) was 50 mL (5–1800 mL). The median OT for RAH was 90 min (43–251 min), and the EBL was 5 mL (5–850 mL), with a significantly shorter OT and a lower EBL in RAH than in TLH. Uterine weight was categorized into four groups in increments of 250 g. The number of cases in each group was 163 (< 250 g), 116 (250–500 g), 41 (500–750 g), and 20 (≥ 750 g) for TLH, and 308 (< 250 g), 137 (250–500 g), 33 (500–750 g), and 25 (≥ 750 g) for RAH. In patients with a uterus < 250 g, there was no significant difference in OT between TLH and RAH, but in patients with a uterus ≥ 250 g, OT tended to be shorter with RAH, which was also true for a uterus ≥ 750 g. The EBL was significantly lower with RAH compared to TLH, regardless of uterine weight. In patients with a large uterus, the advantages of robotic surgery can be utilized, which may lead to a shorter OT and less EBL.