CLCiren Laba

Ciren Laba

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ciren Laba has a total of 12 co-authors. Here are the top co-authors by number of shared publications:

  • Yi Feng

    Department of Anesthesiology, Peking University People’s Hospital, Beijing, China

    2 shared publications
  • Bailin Jiang

    Department of Anesthesiology, Tibet Autonomous Region People’s Hospital, Lhasa, Tibet, China

    1 shared publication
  • Bailin Jiang

    Department of Anesthesiology, Peking University People's Hospital, Beijing, China

    1 shared publication
  • Deji Ci

    Department of Anesthesiology, Tibet Autonomous Region People’s Hospital, Lhasa, China

    1 shared publication
  • Deji Ciren

    Department of Anesthesiology, Tibet Autonomous Region People’s Hospital, Lhasa, Tibet, China

    1 shared publication
  • Dunzhu Zhaxi

    Department of Anesthesiology, Tibet Autonomous Region People’s Hospital, Lhasa, China

    1 shared publication

Latest Publications

  • Open Access

    High-flow nasal cannula oxygen reduced hypoxemia in patients undergoing gastroscopy under general anesthesia at ultra-high altitude: a randomized controlled trial

    by Dunzhu Zhaxi, Deji Ci, Xiang Quan, Ciren Laba

    Background: Hypoxemia can occur in people at ultra-high altitude (above 3500 m) even at rest, and patients undergoing gastroscopy under general anesthesia have higher risk of hypoxemia. Supplementary oxygen via standard nasal cannula (SNC) is the standard of care for most patients who undergo gastroscopy under general anesthesia, which provides oxygen flow up to 15 L/min. High-flow nasal cannula (HFNC) could deliver oxygen at a rate up to 60 L/min, which is recommended by the American Society of Anesthesiologists Practice Guidelines. We speculated that the benefit with HFNC is more prominent in high-altitude areas, and aimed to compare the incidence of hypoxemia during gastroscopy under general anesthesia at ultra-high altitude with oxygen supply via either HFNC or SNC. Methods: The trial was registered at at Chinese Clinical Trial Registry (ChiCTR2100045513; date of registration on 18/04/2021). Adult patients undergoing gastroscopy with anesthesia (estimated duration of anesthesia at ≥ 15 min) were randomized at a 1:1 ratio to receive HFNC oxygen or SNC oxygen. The primary outcome was hypoxemia (SpO2 < 90% for any duration). Secondary outcomes included severe hypoxemia (SpO2 < 75% for any duration or SpO2 < 90% but ≥ 75% for ≥ 60 s) and hypotension, as defined by reduction of mean arterial blood pressure by ≥ 25% from the baseline. Results: A total of 262 patients were enrolled: 129 in the HFNC group and 133 in the SNC group. All patients received the designated intervention. Student’s t-test, Mann-Whitney U test and χ2 test were employed in the study. The rate of hypoxemia was 9.3% (12/129) in the HFNC group versus 36.8% (49/133) in the SNC group [risk ratio (95% confidence interval): 0.25(0.14–0.45); P < 0.001). The HFNC group also had lower rate of severe hypoxemia [0.0% (0/129) versus 11.3% (15/133); risk ratio (95% confidence interval): 0.03(0.00-0.55); P < 0.001, respectively]. The rate of hypotension did not differ between the 2 groups [22.5% (29/129) in HFNC group versus 21.1% (28/133) in SNC group; risk ratio (95% confidence interval): 1.07(0.67–1.69) ; P = 0.779]. Conclusion: HFNC oxygen reduced the incidence of hypoxemia during anesthesia in adult patients undergoing gastroscopy at ultra-high altitude.


  • Open Access

    Optimal Duration of High-Fidelity Simulator Training for Bronchoscope-Guided Intubation

    by Luyang Jiang, Qingmei Bsc Yang, Qingyue Li, Bailin Jiang, Ciren Bsc Laba, Yi Feng

    Introduction: The optimal simulator training duration for flexible optical bronchoscopic (FOB) intubation is unknown. This study aimed to determine whether a learning curve-based training modality was noninferior to a fixed training time modality in terms of clinical FOB intubation time. Methods: This multicenter, randomized, noninferiority study was conducted from May to August 2022. Anesthesiology residents or interns were enrolled. Eligible participants were randomized in a 1:1 ratio to receive new learning curve-based simulator training (individualized training time based on performance, group New) or reference fixed training time simulator training (1 hour, group Reference). The primary outcome was the time to complete FOB intubation in patients, which was defined as the time from the introduction of the FOB into the mouth until the first capnography visualization. The margin for detecting clinical significance was defined as 10 seconds. Results: A total of 32 participants were included in the analysis (16 in each group). All trainees successfully intubated the patients. The mean intubation time (95% confidence interval [CI]) was 81.9 (65.7–98.1) seconds in group New and 97.0 (77.4–116.6) seconds in group Reference. The upper bound of the 1-sided 97.5% CI for the mean difference of clinical intubation time between groups was 9.3 seconds. Noninferiority was claimed. The mean duration of the training in group New was 28.4 (95% CI, 23.5–33.4) minutes. The total number of training procedures on simulators in group New was significantly less than that in group Reference (P < 0.01). Conclusions: The clinical FOB intubation time in group New was noninferior to that in group Reference.

  • Open Access

    Supraglottic jet oxygenation and ventilation decreased hypoxemia during gastrointestinal endoscopy under deep sedation at high altitudes: a randomized clinical trial

    by Bailin Jiang, Yi Li, Deji Ciren, Ouzhu Dawa, Yi Feng, Ciren Laba

    Background: Hypobaric hypoxia is common at high altitudes. Whether this exacerbates hypoxia during procedural sedation and whether hypoxia can be alleviated by the use of supraglottic jet oxygenation and ventilation (SJOV) are unknown. This study aimed to compare the incidence of hypoxia during gastrointestinal endoscopy under deep sedation at high altitudes with oxygen supply techniques using either a nasal cannula or SJOV. Methods: This study was conducted from April 2022 to July 2022 in a tertiary hospital located 3650 m above sea level. Adult patients scheduled for routine gastrointestinal endoscopy under sedation were enrolled and randomized 1:1 to receive SJOV or a nasal cannula during sedation. Moderate hypoxia was the primary outcome, defined as an SPO2 of 75–89% for < 60 s. The secondary outcomes were respiratory-, cardiovascular-, and SJOV-related complications. The influence of characteristics regarding acclimatization to high altitudes (Tibetan ethnic group and erythrocytosis) on the occurrence of hypoxia was analyzed. Results: None of the patients were lost to follow-up. A total of 72 patients were included in the analysis (36 patients in each group). There were 20 (27.8%) patients who experienced moderate hypoxia events. Significantly fewer hypoxic events occurred in the SJOV group than in the nasal cannula group [3 (8.3%) vs. 17 (47.2%), absolute risk difference (95% CI): − 38.9 (− 57.5, − 20.2) %, risk ratio (RR, 95% CI): 0.18 (0.06, 0.55), P < 0.001]. Significantly fewer patients in the SJOV group experienced mild hypoxia (P < 0.001) and severe hypoxia (P = 0.002). No serious adverse events occurred in either of the groups. The Tibetan ethnic group (P = 0.086) and erythrocytosis (P = 0.287) were not associated with the occurrence of hypoxia events. Conclusions: The incidence of hypoxia was lower with SJOV than with nasal cannula in patients undergoing gastrointestinal endoscopy under deep sedation at high altitudes. The Tibetan ethnic group and erythrocytosis did not influence the occurrence of hypoxia. Trial registration: This study was registered at ClinicalTrials.gov (NCT05304923) before enrollment by Dr. Yi Feng on 31/03/2022.