Zhengshan Hong
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Zhengshan Hong has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Ping Li
Department of Radiation Oncology, Shanghai Proton and Heavy Ion Center, Fudan University Cancer Hospital, Shanghai Key Laboratory of Radiation Oncology, Shanghai Engineering Research Center of Proton and Heavy Ion Radiation Therapy, 4365 Kangxin Road, Pudong, Shanghai 201321, China
2 shared publications - Guo-Liang Jiang
Shanghai Key Laboratory of Radiation Oncology (20dz2261000), Shanghai, China; Shanghai Engineering Research Center of Proton and Heavy Ion Radiation Therapy, Shanghai, China; Department of Radiation Oncology, Shanghai Proton and Heavy Ion Center, Fudan University Cancer Hospital, Shanghai, China
1 shared publication - Jingfang Zhao
Department of Medical Physics, Shanghai Proton and Heavy Ion Center, Fudan University Cancer Hospital, Shanghai Key Laboratory of Radiation Oncology (20dz2261000), Shanghai Engineering Research Center of Proton and Heavy Ion Radiation Therapy, Shanghai, China
1 shared publication - Kambiz Shahnazi
Department of Medical Physics, Shanghai Proton and Heavy Ion Center, Shanghai Key Laboratory of Radiation Oncology (20dz226100), Shanghai Engineering Research Center of Proton and Heavy Ion Radiation Therapy, Shanghai, China
1 shared publication - Qing Zhang
Department of Radiation Oncology, Shanghai Proton and Heavy Ion Center, Shanghai, China
1 shared publication - Qing Zhang
Department of Radiation Oncology, Shanghai Proton and Heavy Ion Center, Fudan University Cancer Hospital, Shanghai Key Laboratory of Radiation Oncology, Shanghai Engineering Research Center of Proton and Heavy Ion Radiation Therapy, 4365 Kangxin Road, Pudong, Shanghai 201321, China
1 shared publication
Latest Publications
- Open Access
- 8 November 2022
- Published by Springer Nature in Trials
- Vol. 23 (1) , 1-13
Functional imaging-guided carbon ion irradiation with simultaneous integrated boost for localized prostate cancer: study protocol for a phase II randomized controlled clinical trial
Background: Due to the physical dose distribution characteristic of “Bragg peak” and the biological effect as a kind of high linear energy transfer ray, heavy ion therapy has advantages over conventional photon therapy in both efficacy and safety. Based on the evidence that prostate cancer lesions before treatment are the most common sites of tumor residual or recurrence after treatment, simultaneous integrated boost radiation therapy for prostate cancer has been proven to have the advantage of improving efficacy without increasing toxicities. Methods: This study is a prospective phase II randomized controlled clinical trial evaluating the efficacy and safety of functional imaging-guided carbon ion irradiation with simultaneous integrated boost for localized prostate cancer. One hundred and forty patients with localized prostate cancer will be randomized into carbon ion radiotherapy group and simultaneous integrated boost carbon ion radiotherapy group at a 1:1 ratio. The primary endpoint is to compare the incidence of treatment-related grade 2 and higher acute toxicities between the two groups according to National Cancer Institute Common Terminology Criteria for Adverse Events (NCI-CTCAE) version 4.03. Secondary endpoints are late toxicities, biochemical relapse-free survival, overall survival, progression-free survival, and quality of life. Discussion: This study adopts functional imaging-guided simultaneous integrated boost of carbon ion radiotherapy for localized prostate cancer, aiming to evaluate the differences in the severity and incidence of acute toxicities in patients with localized prostate cancer treated with carbon ion radiotherapy and simultaneous integrated boost carbon ion radiotherapy, in order to optimize the carbon ion treatment strategy for localized prostate cancer. Trial registration: ClinicalTrials.gov NCT05010343. Retrospectively registered on 18 August 2021
- 8 November 2022
- Published by Springer Nature in Trials
- Vol. 23 (1) , 1-13
Open AccessFunctional imaging-guided carbon ion irradiation with simultaneous integrated boost for localized prostate cancer: study protocol for a phase II randomized controlled clinical trial
Background: Due to the physical dose distribution characteristic of “Bragg peak” and the biological effect as a kind of high linear energy transfer ray, heavy ion therapy has advantages over conventional photon therapy in both efficacy and safety. Based on the evidence that prostate cancer lesions before treatment are the most common sites of tumor residual or recurrence after treatment, simultaneous integrated boost radiation therapy for prostate cancer has been proven to have the advantage of improving efficacy without increasing toxicities. Methods: This study is a prospective phase II randomized controlled clinical trial evaluating the efficacy and safety of functional imaging-guided carbon ion irradiation with simultaneous integrated boost for localized prostate cancer. One hundred and forty patients with localized prostate cancer will be randomized into carbon ion radiotherapy group and simultaneous integrated boost carbon ion radiotherapy group at a 1:1 ratio. The primary endpoint is to compare the incidence of treatment-related grade 2 and higher acute toxicities between the two groups according to National Cancer Institute Common Terminology Criteria for Adverse Events (NCI-CTCAE) version 4.03. Secondary endpoints are late toxicities, biochemical relapse-free survival, overall survival, progression-free survival, and quality of life. Discussion: This study adopts functional imaging-guided simultaneous integrated boost of carbon ion radiotherapy for localized prostate cancer, aiming to evaluate the differences in the severity and incidence of acute toxicities in patients with localized prostate cancer treated with carbon ion radiotherapy and simultaneous integrated boost carbon ion radiotherapy, in order to optimize the carbon ion treatment strategy for localized prostate cancer. Trial registration: ClinicalTrials.gov NCT05010343. Retrospectively registered on 18 August 2021
- Open Access
- 13 April 2021
- Published by Springer Nature in Radiation Oncology
- Vol. 16 (1) , 1-8
Conversion and validation of rectal constraints for prostate carcinoma receiving hypofractionated carbon-ion radiotherapy with a local effect model
Background: The study objective was to establish the local effect model (LEM) rectum constraints for 12-, 8-, and 4-fraction carbon-ion radiotherapy (CIRT) in patients with localized prostate carcinoma (PCA) using microdosimetric kinetic model (MKM)-defined and LEM-defined constraints for 16-fraction CIRT. Methods: We analyzed 40 patients with PCA who received 16- or 12-fraction CIRT at our center. Linear-quadratic (LQ) and RBE-conversion models were employed to convert the constraints into various fractionations and biophysical models. Based on them, the MKM LQ strategy converted MKM rectum constraints for 16-fraction CIRT to 12-, 8-, and 4-fraction CIRT using the LQ model. Then, MKM constraints were converted to LEM using the RBE-conversion model. Meanwhile the LEM LQ strategy converted MKM rectum constraints for 16-fraction CIRT to LEM using the RBE-conversion model. Then, LEM constraints were converted from 16-fraction constraints to the rectum constraints for 12-, 8-, and 4-fraction CIRT using the LQ model. The LEM constraints for 16- and 12-fraction CIRT were evaluated using rectum doses and clinical follow-up. To adapt them for the MKM LQ strategy, CNAO LEM constraints were first converted to MKM constraints using the RBE-conversion model. Results: The NIRS (i.e. DMKM|v, V-20%, 10%, 5%, and 0%) and CNAO rectum constraints (i.e. DLEM|v, V-10 cc, 5 cc, and 1 cc) were converted for 12-fraction CIRT using the MKM LQ strategy to LEM 37.60, 49.74, 55.27, and 58.01 Gy (RBE), and 45.97, 51.70, and 55.97 Gy (RBE), and using the LEM LQ strategy to 39.55, 53.08, 58.91, and 61.73 Gy (RBE), and 49.14, 55.30, and 59.69 Gy (RBE). We also established LEM constraints for 8- and 4-fraction CIRT. The 10-patient RBE-conversion model was comparable to 30-patient model. Eight patients who received 16-fraction CIRT exceeded the corresponding rectum constraints; the others were within the constraints. After a median follow-up of 10.8 months (7.1–20.8), No ≥ G1 late rectum toxicities were observed. Conclusions: The LEM rectum constraints from the MKM LQ strategy were more conservative and might serve as the reference for hypofractionated CIRT. However, Long-term follow-up plus additional patients is necessary.
- 13 April 2021
- Published by Springer Nature in Radiation Oncology
- Vol. 16 (1) , 1-8
Open AccessConversion and validation of rectal constraints for prostate carcinoma receiving hypofractionated carbon-ion radiotherapy with a local effect model
Background: The study objective was to establish the local effect model (LEM) rectum constraints for 12-, 8-, and 4-fraction carbon-ion radiotherapy (CIRT) in patients with localized prostate carcinoma (PCA) using microdosimetric kinetic model (MKM)-defined and LEM-defined constraints for 16-fraction CIRT. Methods: We analyzed 40 patients with PCA who received 16- or 12-fraction CIRT at our center. Linear-quadratic (LQ) and RBE-conversion models were employed to convert the constraints into various fractionations and biophysical models. Based on them, the MKM LQ strategy converted MKM rectum constraints for 16-fraction CIRT to 12-, 8-, and 4-fraction CIRT using the LQ model. Then, MKM constraints were converted to LEM using the RBE-conversion model. Meanwhile the LEM LQ strategy converted MKM rectum constraints for 16-fraction CIRT to LEM using the RBE-conversion model. Then, LEM constraints were converted from 16-fraction constraints to the rectum constraints for 12-, 8-, and 4-fraction CIRT using the LQ model. The LEM constraints for 16- and 12-fraction CIRT were evaluated using rectum doses and clinical follow-up. To adapt them for the MKM LQ strategy, CNAO LEM constraints were first converted to MKM constraints using the RBE-conversion model. Results: The NIRS (i.e. DMKM|v, V-20%, 10%, 5%, and 0%) and CNAO rectum constraints (i.e. DLEM|v, V-10 cc, 5 cc, and 1 cc) were converted for 12-fraction CIRT using the MKM LQ strategy to LEM 37.60, 49.74, 55.27, and 58.01 Gy (RBE), and 45.97, 51.70, and 55.97 Gy (RBE), and using the LEM LQ strategy to 39.55, 53.08, 58.91, and 61.73 Gy (RBE), and 49.14, 55.30, and 59.69 Gy (RBE). We also established LEM constraints for 8- and 4-fraction CIRT. The 10-patient RBE-conversion model was comparable to 30-patient model. Eight patients who received 16-fraction CIRT exceeded the corresponding rectum constraints; the others were within the constraints. After a median follow-up of 10.8 months (7.1–20.8), No ≥ G1 late rectum toxicities were observed. Conclusions: The LEM rectum constraints from the MKM LQ strategy were more conservative and might serve as the reference for hypofractionated CIRT. However, Long-term follow-up plus additional patients is necessary.