SASura M. Ahmed

Sura M. Ahmed

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sura M. Ahmed has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Corneal Elevation Maps Patterns Classification Using Correlation Method

    by Sura M. Ahmed, Nebras H. Ghaeb, Salman Yussof, Noor T. Al-Sharify, Husam Yahya Nser, Zainab T. Al-Sharify, Ong Hang See, Leong Yeng Weng

    The ophthalmologist uses various techniques to diagnose corneal abnormalities, including corneal topography and tomography devices. Currently generated color corneal elevation surface maps from topographic imaging devices are essential for detecting ocular diseases, while accurately classifying these maps to differentiate between different shapes remains an issue. This study aims to assess and compare parameters of the front and back corneal surface elevation map patterns of normal/abnormal corneas. Two hundred cases were randomly taken (100 normal and 100 abnormal) with a single normal reference image, and then an additional 25 cases were added later for the optimization process. The preprocessing of all images involved converting them from color to black and white images to highlight the elevation bowtie shapes. The correlation coefficient, as implemented in MATLAB, was used to identify similar shapes of bowties for both normal and abnormal cases and determine the elevation values at the thinnest location. Additionally, it was used to measure the elevation bowtie angle between the reference normal image (case) and all other cases for image classification. Individually, the cut-off value of maximum correlation (mean ± 2 standard deviation) was calculated to distinguish between normal/abnormal patterns for 200 cases, and the cut-off values (0.974418 ≥ correlation ≥ 0.575, 0.994548 ≥ correlation ≥ 0.537841) were used for elevation back and front, respectively. Normal angle has cut-off values of (≤ 25 and =90), while normal elevation values at the thinnest location are (≤ 15, ≤ 20) for front and back surfaces. This method is based on elevation back, achieving an accuracy of 74%, and an accuracy of 64% was achieved for elevation front. Our model’s final accuracy was calculated by combining both the elevation back and elevation front final results to achieve 75.5% accuracy. Adding more data will not further increase the accuracy output since it has reached its optimal level. The development of this method aims to assist ophthalmologists in diagnosing and confirming clinical decisions through the accurate detection of corneal disease.

  • Open Access

    Advances in Corneal Diagnostics Using Machine Learning

    by Noor T. Al-Sharify, Salman Yussof, Nebras H. Ghaeb, Zainab T. Al-Sharify, Husam Yahya Naser, Sura M. Ahmed, Ong Hang See, Leong Yeng Weng

    This paper provides comprehensive insights into the cornea and its diseases, with a particular focus on keratoconus. This paper explores the cornea’s function in maintaining ocular health, detailing its anatomy, pathological conditions, and the latest developments in diagnostic techniques. Keratoconus is discussed extensively, covering its subtypes, etiology, clinical manifestations, and the application of the Q-value for quantification. Several diagnostic techniques, such as corneal topography, are crucial points of discussion. This paper also examines the use of machine learning models, specifically Decision Tree and Nearest Neighbor Analysis, which enhance the accuracy of diagnosing based on topographical corneal parameters from corneal topography. These models provide valuable insights into disease progression and aid in clinical decision making. Integrating these technologies in medical research opens promising avenues for enhanced disease detection. Our findings demonstrate the effectiveness of Decision Tree and Nearest Neighbor Analysis in classifying and predicting conditions based on corneal parameters. The Decision Tree achieved classification accuracy of 62% for training and 65.7% for testing, while Nearest Neighbor Analysis yielded 65.4% for training and 62.6% for holdout samples. These models offer valuable insights into the progression and severity of keratoconus, aiding clinicians in treatment and management decisions.


  • Open Access

    Influence of different parameters on the corneal asphericity (Q value) assessed with progress in biomedical optics and imaging – A review

    by Noor T. Al-Sharify, Husam Yahya Nser, Nebras H. Ghaeb, Zainab T. Al-Sharify, Ong Hang See, Leong Yeng Weng, Sura M. Ahmed


  • Open Access

    Keratoconus: A discussion of physical/chemical properties and clinical diagnosis modalities. A review

    by Sura M. Ahmed, Noor T. Al-Sharify, Husam Yahya Nser, Zainab T. Al-Sharify, Nebras H. Ghaeb, Ong Hang See, Leong Yeng Weng

    The anterior densely innervated corneal tissue determines more than 50% of the optical power reflection. The Cornea’s structure is composed of six layers, from the epithelium to the endothelium, and a deficiency in one of these layers produces various illnesses that result in alterations in the tissue’s physical and chemical characteristics. One of the mane problems happened to eye cornea is found during Keratoconus (KC), where the Cornea shape changes from normal aspherical to the cone-like protrusion of the central Cornea. This affected tissue suffers from decreased vision due to myopia, irregular astigmatism, and corneal scarring. A comprehensive review was done to investigate the Physical, chemical Properties and Clinical Diagnosis Modalities in the current work for patients with Keratoconu. Physically, where the Cornea is irregular in shape, incoming light rays cannot be focused on a single point, causing the wavefront’s typical spherical shape to change. In addition, the chemical structure of basal epithelial cells influences their shape and arrangement. At the same time, a break in Bowman’s layer, which is common in keratoconus, may be responsible for the conical shape of the eye. Various technologies such as keratometry, Slit lamp, Ultrasound Pachymetry, and corneal topography/tomography have been used for diagnosing KC corneas. Each of them provides essential parameters and indicates the Cornea’s state. Nowadays, corneal topography techniques allow for identifying the major morphological features of diseased tissue. Furthermore, early detection of KC is critical for avoiding ocular refractive surgery, but there are no standardized screening criteria for early diagnosis.

  • Open Access

    Corneal topography, an overview of its devices and systems – A review

    by Noor T. Al-Sharify, Sura M. Ahmed, Husam Yahya Nser, Ong Hang See, Zainab T. Al-Sharify, Nebras H. Ghaeb, Leong Yeng Weng

    With advancements in technology, it is now possible to explore the characteristics of a cornea in depth. A computer-aided diagnostic tool known as corneal topog


  • Open Access

    Review study of refraction error measurement methods of human cornea

    by Husam Yahya Nser, Noor T. Al-Sharify, Sura M. Ahmed, Leong Yeng Weng, Ong Hang See, Zainab T. Al-Sharify, Nebras H. Ghaeb

    This paper aims to comprehensively review the refractive error measurement theories in human cornea, which is considered one of the most important theories used