Chengqi Jia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Chengqi Jia has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Xuesong Zhang
School of Medicine, Nankai University, Tianjin, 300071, China
4 shared publications - Yong-Gang You
Department of Orthopaedics, the Fourth Medical Center of PLA General Hospital, Beijing 100048, China
3 shared publications - Fanqi Hu
Department of Orthopaedics, The Fourth Medical Centre, Chinese PLA General Hospital, Beijing, 100048, China
2 shared publications - Hai-Chao Yu
School of Medicine, Nankai University, Tianjin 300071, China
2 shared publications - Jun Zhao
CAS Key Laboratory of Nanosystem and Hierarchical Fabrication, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology, Beijing 100190, China
2 shared publications - Shiqi Cao
Department of Orthopaedics, Senior Department of Traditional Chinese Medicine, The Sixth Medical Center of PLA General Hospital, Beijing, People’s Republic of China
2 shared publications
Latest Publications
- Open Access
- 6 August 2026
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 21 (1)
Reinfection rates after debridement, antibiotics, and implant retention, one-stage and two-stage revision for fungal periprosthetic joint infection following total hip and knee arthroplasty: a meta-analysis and systematic review
- 6 August 2026
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 21 (1)
Open AccessReinfection rates after debridement, antibiotics, and implant retention, one-stage and two-stage revision for fungal periprosthetic joint infection following total hip and knee arthroplasty: a meta-analysis and systematic review
- Top Cited PapersOpen Access
- 1 February 2024
- Published by KEAI Publishing in Bioactive Materials
- Vol. 32, 164-176
Supramolecular self-assembly of EGCG-selenomethionine nanodrug for treating osteoarthritis
Osteoarthritis (OA) has emerged as a significant health concern among the elderly population, with increasing attention paid to ferroptosis-induced OA in recent years. However, the prolonged use of nonsteroidal anti-inflammatory drugs or corticosteroids can lead to a series of side effects and limited therapeutic efficacy. This study aimed to employ the Mannich condensation reaction between epigallocatechin-3-gallate (EGCG) and selenomethionine (SeMet) to efficiently synthesize polyphenol-based nanodrugs in aqueous media for treating OA. Molecular biology experiments demonstrated that EGCG-based nanodrugs (ES NDs) could effectively reduce glutathione peroxidase 4 (GPX4) inactivation, abnormal Fe2+ accumulation, and lipid peroxidation induced by oxidative stress, which ameliorated the metabolic disorder of chondrocytes and other multiple pathological processes triggered by ferroptosis. Moreover, imaging and histopathological analysis of the destabilization of the medial meniscus model in mice confirmed that ES NDs exhibiting significant therapeutic effects in relieving OA. The intra-articular delivery of ES NDs represents a promising approach for treating OA and other joint inflammatory diseases.
- 1 February 2024
- Published by KEAI Publishing in Bioactive Materials
- Vol. 32, 164-176
Top Cited PapersOpen AccessSupramolecular self-assembly of EGCG-selenomethionine nanodrug for treating osteoarthritis
Osteoarthritis (OA) has emerged as a significant health concern among the elderly population, with increasing attention paid to ferroptosis-induced OA in recent years. However, the prolonged use of nonsteroidal anti-inflammatory drugs or corticosteroids can lead to a series of side effects and limited therapeutic efficacy. This study aimed to employ the Mannich condensation reaction between epigallocatechin-3-gallate (EGCG) and selenomethionine (SeMet) to efficiently synthesize polyphenol-based nanodrugs in aqueous media for treating OA. Molecular biology experiments demonstrated that EGCG-based nanodrugs (ES NDs) could effectively reduce glutathione peroxidase 4 (GPX4) inactivation, abnormal Fe2+ accumulation, and lipid peroxidation induced by oxidative stress, which ameliorated the metabolic disorder of chondrocytes and other multiple pathological processes triggered by ferroptosis. Moreover, imaging and histopathological analysis of the destabilization of the medial meniscus model in mice confirmed that ES NDs exhibiting significant therapeutic effects in relieving OA. The intra-articular delivery of ES NDs represents a promising approach for treating OA and other joint inflammatory diseases.
- Open Access
Preparation and Characterization of Body-Temperature-Responsive Thermoset Shape Memory Polyurethane for Medical Applications
Shape memory polymers (SMPs) are currently one of the most attractive smart materials expected to replace traditional shape memory alloys and ceramics (SMAs and SMCs, respectively) in some fields because of their unique properties of high deformability, low density, easy processing, and low cost. As one of the most popular SMPs, shape memory polyurethane (SMPU) has received extensive attention in the fields of biomedicine and smart textiles due to its biocompatibility and adjustable thermal transition temperature. However, its laborious synthesis, limitation to thermal response, poor conductivity, and low modulus limit its wider application. In this work, biocompatible poly(ε-caprolactone) diol (PCL-2OH) is used as the soft segment, isophorone diisocyanate (IPDI) is used as the hard segment, and glycerol (GL) is used as the crosslinking agent to prepare thermoset SMPU with a thermal transition temperature close to body temperature for convenient medical applications. The effects of different soft-chain molecular weights and crosslinking densities on the SMPU’s properties are studied. It is determined that the SMPU has the best comprehensive performance when the molar ratio of IPDI:PCL-2OH:GL is 2:1.5:0.33, which can trigger shape memory recovery at body temperature and maintain 450% recoverable strain. Such materials are excellent candidates for medical devices and can make great contributions to human health.
Open AccessPreparation and Characterization of Body-Temperature-Responsive Thermoset Shape Memory Polyurethane for Medical Applications
Shape memory polymers (SMPs) are currently one of the most attractive smart materials expected to replace traditional shape memory alloys and ceramics (SMAs and SMCs, respectively) in some fields because of their unique properties of high deformability, low density, easy processing, and low cost. As one of the most popular SMPs, shape memory polyurethane (SMPU) has received extensive attention in the fields of biomedicine and smart textiles due to its biocompatibility and adjustable thermal transition temperature. However, its laborious synthesis, limitation to thermal response, poor conductivity, and low modulus limit its wider application. In this work, biocompatible poly(ε-caprolactone) diol (PCL-2OH) is used as the soft segment, isophorone diisocyanate (IPDI) is used as the hard segment, and glycerol (GL) is used as the crosslinking agent to prepare thermoset SMPU with a thermal transition temperature close to body temperature for convenient medical applications. The effects of different soft-chain molecular weights and crosslinking densities on the SMPU’s properties are studied. It is determined that the SMPU has the best comprehensive performance when the molar ratio of IPDI:PCL-2OH:GL is 2:1.5:0.33, which can trigger shape memory recovery at body temperature and maintain 450% recoverable strain. Such materials are excellent candidates for medical devices and can make great contributions to human health.
- Open Access
- 9 December 2022
- Published by Springer Nature in European Journal of Medical Research
- Vol. 27 (1) , 1-8
Mid-term outcomes after total hip arthroplasty in 106 Crowe II/III hips: different hip center positions
Background: Under the obvious acetabular superolateral bone defect of Crowe II/III hips, this study aimed to investigate the difference in surgical technique of different hip center positions from the surgical data and clinical outcomes. Methods: From July 2007 to December 2016, 87 patients (106 Crowe II/III hips) consecutively received total hip arthroplasty (THA). The minimum follow-up time was 5 years. The mean limb length discrepancy was 1.97 ± 1.81 cm. Twenty-four hips had surgical histories. The patients were divided into three groups according to the acetabular prosthesis positions, depending on the Crowe classification, respectively, group 1 (Crowe I), group 2 (Crowe II) and group 3 (Crowe III). The surgical data and clinical results were used to evaluate the outcome of different surgical techniques of different hip center positions, including surgical time, blood loss, blood transfusion, number of osteotomy hips, osteotomy length, the distribution of prothesis, postoperative inpatient days, Harris hip scores, Visual Analogue Scale (VAS), Back Pain Function Scale (BPFS) and complications. Results: The mean follow-up time was 8.93 ± 2.55 years. Nineteen hips performed intraoperative osteotomy. From group 1 to group 3, the mean osteotomy length were 0.53 ± 1.11 cm, 0.05 ± 0.22 cm, and 0.00 ± 0.00 cm, respectively (p = 0.083); the surgical time were 142.57 ± 57.94 min, 118.4 ± 41.22 min, and 120.00 ± 84.85 min, respectively (p = 0.324); the blood loss were 498.21 ± 368.53 mL, 333.33 ± 167.62 mL, and 350.00 ± 212.13 mL, respectively (p = 0.255); the blood transfusion were 288.48 ± 381.68 mL, 128.00 ± 235.17 mL, and 385.00 ± 219.20 mL, respectively (p = 0.199); the postoperative inpatient days were 7.95 ± 4.42 d, 7.47 ± 4.29 d, and 6.50 ± 0.71 d, respectively (p = 0.831). Among the groups, the distribution of acetabular prosthesis, acetabular liner, acetabular prosthesis sizes, femoral head sizes and femoral prothesis distal sizes were not significantly different (p > 0.05). Only the distribution of femoral prosthesis was significantly different (p = 0.046); the Harris, VAS, BPFS, and the distribution of complications were not significantly different (p > 0.05). Conclusions: We provided a framework to guide decision-making in Crowe II/III hips for surgeons: the surgical technique of different hip center positions was stable and had good outcomes, but the acetabular prothesis position and femoral prothesis should be determined according to the intraoperative situation. Level of evidence: Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.
- 9 December 2022
- Published by Springer Nature in European Journal of Medical Research
- Vol. 27 (1) , 1-8
Open AccessMid-term outcomes after total hip arthroplasty in 106 Crowe II/III hips: different hip center positions
Background: Under the obvious acetabular superolateral bone defect of Crowe II/III hips, this study aimed to investigate the difference in surgical technique of different hip center positions from the surgical data and clinical outcomes. Methods: From July 2007 to December 2016, 87 patients (106 Crowe II/III hips) consecutively received total hip arthroplasty (THA). The minimum follow-up time was 5 years. The mean limb length discrepancy was 1.97 ± 1.81 cm. Twenty-four hips had surgical histories. The patients were divided into three groups according to the acetabular prosthesis positions, depending on the Crowe classification, respectively, group 1 (Crowe I), group 2 (Crowe II) and group 3 (Crowe III). The surgical data and clinical results were used to evaluate the outcome of different surgical techniques of different hip center positions, including surgical time, blood loss, blood transfusion, number of osteotomy hips, osteotomy length, the distribution of prothesis, postoperative inpatient days, Harris hip scores, Visual Analogue Scale (VAS), Back Pain Function Scale (BPFS) and complications. Results: The mean follow-up time was 8.93 ± 2.55 years. Nineteen hips performed intraoperative osteotomy. From group 1 to group 3, the mean osteotomy length were 0.53 ± 1.11 cm, 0.05 ± 0.22 cm, and 0.00 ± 0.00 cm, respectively (p = 0.083); the surgical time were 142.57 ± 57.94 min, 118.4 ± 41.22 min, and 120.00 ± 84.85 min, respectively (p = 0.324); the blood loss were 498.21 ± 368.53 mL, 333.33 ± 167.62 mL, and 350.00 ± 212.13 mL, respectively (p = 0.255); the blood transfusion were 288.48 ± 381.68 mL, 128.00 ± 235.17 mL, and 385.00 ± 219.20 mL, respectively (p = 0.199); the postoperative inpatient days were 7.95 ± 4.42 d, 7.47 ± 4.29 d, and 6.50 ± 0.71 d, respectively (p = 0.831). Among the groups, the distribution of acetabular prosthesis, acetabular liner, acetabular prosthesis sizes, femoral head sizes and femoral prothesis distal sizes were not significantly different (p > 0.05). Only the distribution of femoral prosthesis was significantly different (p = 0.046); the Harris, VAS, BPFS, and the distribution of complications were not significantly different (p > 0.05). Conclusions: We provided a framework to guide decision-making in Crowe II/III hips for surgeons: the surgical technique of different hip center positions was stable and had good outcomes, but the acetabular prothesis position and femoral prothesis should be determined according to the intraoperative situation. Level of evidence: Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.
- Open Access
- 16 November 2022
- Published by KEAI Publishing in Bioactive Materials
- Vol. 23, 234-246
A biomimetic gradient porous cage with a micro-structure for enhancing mechanical properties and accelerating osseointegration in spinal fusion
Spinal fusion is a widely employed treatment of patients with degenerative disc disease, in which a cage is used to replace the disc for spinal fusion. But it often fails for insufficient mechanical strength and poor osseointegration. Here, we designed a polyether-ether-ketone (PEEK)/tantalum (Ta) composite cage with a biomimetic gradient porous micro-structure, simultaneously enhancing mechanical properties and accelerating osseointegration in spinal fusion. In the study, based on the mechanical performances of PEEK and osteogenic potential of Ta, and the three-dimensional (3D) structures of cuttlebone and vertebra, the cages were respectively 3D printed by pure PEEK, PEEK with 5 wt% Ta (PEEK/Ta-5), PEEK with 10 wt% Ta (PEEK/Ta-10) and PEEK with 15 wt% Ta (PEEK/Ta-15), then verified in vitro and in sheep cervical fusion model systematically. Vertebral Gyroid structure PEEK/Ta-15 cage exhibited superior mechanical properties than Cuttlebone-like structure PEEK/Ta-15 cage, closer to the cervical vertebra. Furthermore, PEEK/Ta-15 cage with higher Ta microparticles in PEEK provided a biomimetic gradient porous micro-structure with higher surface energy, guiding cell biological behavior, promoting new bone penetration, and accelerating osseointegration in vivo. In conclusion, the study designed a biomimetic gradient porous cage with a micro-structure for enhancing mechanical properties, accelerating osseointegration and forming an anatomical lock in the fusion segment through composites, mechanical efficiency, surface extension, and pores.
- 16 November 2022
- Published by KEAI Publishing in Bioactive Materials
- Vol. 23, 234-246
Open AccessA biomimetic gradient porous cage with a micro-structure for enhancing mechanical properties and accelerating osseointegration in spinal fusion
Spinal fusion is a widely employed treatment of patients with degenerative disc disease, in which a cage is used to replace the disc for spinal fusion. But it often fails for insufficient mechanical strength and poor osseointegration. Here, we designed a polyether-ether-ketone (PEEK)/tantalum (Ta) composite cage with a biomimetic gradient porous micro-structure, simultaneously enhancing mechanical properties and accelerating osseointegration in spinal fusion. In the study, based on the mechanical performances of PEEK and osteogenic potential of Ta, and the three-dimensional (3D) structures of cuttlebone and vertebra, the cages were respectively 3D printed by pure PEEK, PEEK with 5 wt% Ta (PEEK/Ta-5), PEEK with 10 wt% Ta (PEEK/Ta-10) and PEEK with 15 wt% Ta (PEEK/Ta-15), then verified in vitro and in sheep cervical fusion model systematically. Vertebral Gyroid structure PEEK/Ta-15 cage exhibited superior mechanical properties than Cuttlebone-like structure PEEK/Ta-15 cage, closer to the cervical vertebra. Furthermore, PEEK/Ta-15 cage with higher Ta microparticles in PEEK provided a biomimetic gradient porous micro-structure with higher surface energy, guiding cell biological behavior, promoting new bone penetration, and accelerating osseointegration in vivo. In conclusion, the study designed a biomimetic gradient porous cage with a micro-structure for enhancing mechanical properties, accelerating osseointegration and forming an anatomical lock in the fusion segment through composites, mechanical efficiency, surface extension, and pores.