NXNuozhou Xu

Nuozhou Xu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nuozhou Xu has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A rapid joint in-situ triaxial magnetic field compensation method for dual-beam SERF magnetometers

    by Nuozhou Xu, Peiling Cui, Kaixuan Zhang, Shuying Wang, Yibo Qi, Xiaoyan Gao, Jixi Lu

    In-situ magnetic field compensation is essential for spin-exchange relaxation-free (SERF) magnetometers to achieve high-sensitivity magnetic field measurements, since the SERF regime requires the vapor cell to operate under a near-zero magnetic field. In this work, we propose a rapid joint in-situ compensation method for dual-beam SERF magnetometers. By applying a high-frequency modulation magnetic field along the sensitive axis, both the first-harmonic signal and the DC signal are simultaneously obtained through demodulation. According to their distinct response characteristics, the first-harmonic signal is combined with the golden-section search algorithm for rapid coarse localization, whereas the DC signal is combined with the bisection algorithm to precisely determine the compensation zero-point. Experimental results demonstrate that the proposed method achieves a compensation range of 100 nT along each axis. The automatic triaxial compensation is completed in approximately 9.5 s, and pT-level compensation resolution is verified using calibrated magnetic field signals. These results indicate that the proposed method provides rapid and wide-range in-situ compensation for dual-beam SERF magnetometers. The method can rapidly establish near-zero-field conditions under different initial residual magnetic fields. It extends the compensation magnetic field range while increasing both compensation speed and near-zero-field precision, thereby improving the adaptability of dual-beam SERF magnetometers and enhancing their practical applicability in high-sensitivity magnetic field measurement.

  • Testing of magnetic shielding system exceeding 10 10 damping based on ultrasensitive atomic magnetometer

    by Xiaoyan Gao, Shuying Wang, Yibo Qi, Bo Li, Nuozhou Xu, Xihui Ye, Jixi Lu

    High-performance magnetic shielding systems require accurate shielding factor (SF) evaluation, yet testing ultra-high-performance systems (SF > 10 8 ) remains challenging due to the need for impractically large external excitation fields. We developed a testing system specifically designed for this task, based on a portable atomic magnetometer, achieving a sensitivity better than 1 f T/Hz 1/2 . By applying an order of 10 4 nT external field via uniform coils and extracting signals via noise spectrum analysis, we achieved the capability to test SFs up to the order of 10 10 at a signal-to-noise ratio of 2. Testing of 10‐layer magnetic shielding cylinders revealed a pronounced frequency dependence of the SF within the 1–100 Hz band. The radial SF ranges from 1.7 × 10 9 to 5.0 × 10 10 , while the axial SF varies between 4.8 × 10 7 and 1.3 × 10 10 , exhibiting the characteristic of an initial increase followed by a decrease with frequency. Furthermore, the phase-frequency characteristics, which are often overlooked in previous studies, were also tested. The results revealed pronounced hysteresis, which is of great significance for practical applications involving real-time magnetic field closed-loop systems.

  • Coupling-Free Magnetic Field Coils at Identical Surface Inside Magnetic Shielding Systems

    by Jixi Lu, Xiaoyan Gao, Shuying Wang, Yibo Qi, Nuozhou Xu, Xihui Ye, Lei Wang

    In precision magnetic field measurement, the combination system of magnetic shielding devices and coils is essential to provide a stable and controllable magnetic field environment. However, close proximity between coils and shielding introduces severe coupling effects that degrade performance of the system. Self-shielded coil is conventionally used to reduce this effect, but its suppression effect is limited, and its nested configuration causes a large volume waste. To address the problem, we propose a novel design method for coupling-free magnetic field coil set, including main coils and shielded coils, at identical surface inside magnetic shielding systems, which can achieve ultra-high coupling-resistance and uniformity with maximum space saving. Based on the Fourier-Bessel function and magnetic field boundary condition, analytical models for magnetic field of the designed coils set under free and ferromagnetic boundaries are established, respectively. Through comparative analysis, the additional term caused by the coupling effect is separated, which enables the complete suppression of the coupling effect at the source. In addition, the quantum-inspired genetic algorithm is employed to solve the complex problem with strong constraints of higher performance and identical surface configuration efficiently. Taking the most commonly used circular coils in the shielding cylinder as the optimization object, we carry out the optimization. Experimental results demonstrate that our optimized coils reduce coupling factor to 0.28%, and improve uniformity to the order of 10⁻⁴ without any volume loss. The method can also be extended to other types of coils and magnetic shielding configurations to improve the accuracy of magnetic field measurement.


  • Uniform Magnetic Field Coils Decoupling Under Ferromagnetic Boundary

    by Xiaoyan Gao, Shuying Wang, Yibo Qi, Nuozhou Xu, Xihui Ye, Jixi Lu

    The high-performance weak magnetic field system consisting of active and passive components is urgently required in fields such as industrial electronics, biomedicine, frontier scientific research and quantum metrology. However, the accuracy of the system will be inevitably affected by the coupling effect between active magnetic field coils and the magnetic shield materials with high permeability. In this study, we proposed a design method of uniform magnetic field coils decoupling under ferromagnetic boundary, which can essentially eliminate the influence of coupling effect on magnetic field profiles. Based on Green’s function and the mirror image method, the magnetic field profile is formulated, in which the coupled and uncoupled terms are separated. Correspondingly, the coupling ratio which is determined by the coupling term and the relative magnetic field error are taken as two objectives. Combined with the multipole expansion of magnetic vector potential, the constraints between the coil parameters are constructed, and optimal coil structural parameters are achieved by using multi-objective particle swarm optimization algorithm. Compared with the conventional structure, the designed coil-set can significantly reduce the coupling ratio from 27% to 0.34%, almost 3 orders of magnitude, meanwhile improve the uniformity by about 46%. We further apply the designed coil-set to the closed-loop control in the zero-field environment, and it shows excellent dynamic performance under ferromagnetic boundary comprehensively. The proposed method can quantitatively evaluate the coupling effect on magnetic field, with universal applicability to various magnetic shielding scenarios. It can pave the way for applications that require extremely high-precision magnetic fields.


  • Femtotesla Spin-Exchange Relaxation-Free Atomic Magnetometer With a Multipass Cell

    by Yibo Qi, Bo Li, Shuying Wang, Nuozhou Xu, Yujie Qian, Jixi Lu

    Miniaturized high-sensitivity atomic magnetometers play a crucial role in biomagnetic measurements. The utilization of multipass cells enhances the sensitivity of atomic magnetometers. This study explores the benefits of employing a multipass cell in spin-exchange relaxation-free (SERF) atomic magnetometers through theoretical and experimental analysis. A signal-to-noise ratio (SNR) model was established by accounting for the optimal detuning frequency of the probe light and low-frequency 1/f noise. This enabled the optimal number of probe light passes through the vapor cell to be determined. Additionally, compact and symmetric reflective optical paths were designed to mitigate polarization gradients in atomic magnetometers with high atomic number density. Experimental results confirmed that the magnetic field sensitivity of the triple-pass configuration (1.8 fT/Hz $^{1/2}$ ) was 1.89 times that of the single-pass configuration (3.4 fT/Hz $^{1/2}$ ), consistent with the theoretical analysis. This study provides valuable theoretical guidance for analyzing the SNR performance of SERF atomic magnetometers and demonstrates the potential of multipass cells in enhancing their magnetic field sensitivity. The utilization of multipass cells presents a viable approach toward the realization of highly sensitive and portable miniaturized SERF atomic magnetometers.


  • Design of Compact Self-Shielded Uniform Magnetic Field Coils Based on Multipole Moment Optimization

    by Shuying Wang, Jixi Lu, Fei Lu, Nuozhou Xu, Yibo Qi, Xu Zhang

    Uniform magnetic field coils are essential for generating accurate magnetic fields that meet a variety of application requirements. However, the magnetic fields generated by such coils lose their original distribution characteristics owing to various interference factors, such as the coupling effect between the coil and magnetic material and crosstalk between adjacent coils. Herein, we propose a novel method for designing self-shielded uniform magnetic field coils to fundamentally solve the magnetic field distortion problem by preadjusting the field distribution characteristics, which particularly enable compact applications. Taylor series expansions were used to ensure field uniformity inside the coil, and multipole moment cancellation was applied to promote the attenuation of the external magnetic field. Further, a function balancing uniformity and attenuation was introduced into the optimization model. The performance of the proposed method did not depend on the selection of characteristic points, which solved the problem of universality and was superior to that of the conventional method. Moreover, the method could significantly reduce the volume of the resulting coils. Simulation and experimental results indicated that the maximum magnetic field error generated in the central region of the designed coil was on the order of 10 -4 regardless of the boundary condition (free or ferromagnetic) and that the field attenuation ratio at the same external position was lower by an order of magnitude compared with that of the commonly used Lee-Whiting coil.