Stephen R. Deiss
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Stephen R. Deiss has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Gert Cauwenberghs
University of California, San Diego
3 shared publications - Abhinav Uppal
Institute for Neural Computation UC San Diego 9500 Gilman Dr La Jolla 92093 CA USA
1 shared publication - Akshay Paul
Shu Chien-Gene Lay Department of Bioengineering, University of California San Diego, La Jolla, CA, USA
1 shared publication - Christopher Deng
Institute for Neural Computation UC San Diego 9500 Gilman Dr La Jolla 92093 CA USA
1 shared publication - Diana Vins
Institute for Neural Computation UC San Diego 9500 Gilman Dr La Jolla 92093 CA USA
1 shared publication - Gopabandhu Hota1 shared publication
Latest Publications
- Open Access
HiAER-Spike Software-Hardware Reconfigurable Platform for Event-Driven Neuromorphic Computing at Scale
In this work, we present HiAER-Spike, a modular, reconfigurable, event-driven neuromorphic computing platform designed to execute large spiking neural networks with up to 160 million neurons and 40 billion synapses - roughly twice the neurons of a mouse brain at faster than real time. This system, assembled at the UC San Diego Supercomputer Center, comprises a co-designed hard- and software stack that is optimized for run-time massively parallel processing and hierarchical address-event routing (HiAER) of spikes while promoting memory-efficient network storage and execution. The architecture efficiently handles both sparse connectivity and sparse activity for robust and low-latency event-driven inference for both edge and cloud computing. A Python programming interface to HiAER-Spike, agnostic to hardware-level detail, shields the user from complexity in the configuration and execution of general spiking neural networks with minimal constraints in topology. The system is made easily available over a web portal for use by the wider community. In the following, we provide an overview of the hard- and software stack, explain the underlying design principles, demonstrate some of the system's capabilities and solicit feedback from the broader neuromorphic community. Examples are shown demonstrating HiAER-Spike's capabilities for event-driven vision on benchmark CIFAR-10, DVS event-based gesture, MNIST, and Pong tasks.
Open AccessHiAER-Spike Software-Hardware Reconfigurable Platform for Event-Driven Neuromorphic Computing at Scale
In this work, we present HiAER-Spike, a modular, reconfigurable, event-driven neuromorphic computing platform designed to execute large spiking neural networks with up to 160 million neurons and 40 billion synapses - roughly twice the neurons of a mouse brain at faster than real time. This system, assembled at the UC San Diego Supercomputer Center, comprises a co-designed hard- and software stack that is optimized for run-time massively parallel processing and hierarchical address-event routing (HiAER) of spikes while promoting memory-efficient network storage and execution. The architecture efficiently handles both sparse connectivity and sparse activity for robust and low-latency event-driven inference for both edge and cloud computing. A Python programming interface to HiAER-Spike, agnostic to hardware-level detail, shields the user from complexity in the configuration and execution of general spiking neural networks with minimal constraints in topology. The system is made easily available over a web portal for use by the wider community. In the following, we provide an overview of the hard- and software stack, explain the underlying design principles, demonstrate some of the system's capabilities and solicit feedback from the broader neuromorphic community. Examples are shown demonstrating HiAER-Spike's capabilities for event-driven vision on benchmark CIFAR-10, DVS event-based gesture, MNIST, and Pong tasks.
- 3 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 17 (3) , 483-494
A Versatile In-Ear Biosensing System and Body-Area Network for Unobtrusive Continuous Health Monitoring
To enable continuous, mobile health monitoring, body-worn sensors need to offer comparable performance to clinical devices in a lightweight, unobtrusive package. This work presents a complete versatile wireless electrophysiology data acquisition system (weDAQ) that is demonstrated for in-ear electroencephalography (EEG) and other on-body electrophysiology with user-generic dry-contact electrodes made from standard printed circuit boards (PCBs). Each weDAQ device provides 16 recording channels, driven right leg (DRL), a 3-axis accelerometer, local data storage, and adaptable data transmission modes. The weDAQ wireless interface supports deployment of a body area network (BAN) capable of aggregating various biosignal streams over multiple worn devices simultaneously, on the 802.11n WiFi protocol. Each channel resolves biopotentials ranging over 5 orders of magnitude with a noise level of 0.52$\mathrm{\upmu }\mathrm{V}$ $\mathrm{_{rms}}$ over a 1000-Hz bandwidth, and a peak SNDR of 119 dB and CMRR of 111 dB at 2 ksps. The device leverages in-band impedance scanning and an input multiplexer to dynamically select good skin contacting electrodes for reference and sensing channels. In-ear and forehead EEG measurements taken from subjects captured modulation of alpha brain activity, electrooculogram (EOG) characteristic eye movements, and electromyogram (EMG) from jaw muscles. Simultaneous ECG and EMG measurements were demonstrated on multiple, freely-moving subjects in their natural office environment during periods of rest and exercise. The small footprint, performance, and configurability of the open-source weDAQ platform and scalable PCB electrodes presented, aim to provide the biosensing community greater experimental flexibility and lower the barrier to entry for new health monitoring research.- 3 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 17 (3) , 483-494
A Versatile In-Ear Biosensing System and Body-Area Network for Unobtrusive Continuous Health Monitoring
To enable continuous, mobile health monitoring, body-worn sensors need to offer comparable performance to clinical devices in a lightweight, unobtrusive package. This work presents a complete versatile wireless electrophysiology data acquisition system (weDAQ) that is demonstrated for in-ear electroencephalography (EEG) and other on-body electrophysiology with user-generic dry-contact electrodes made from standard printed circuit boards (PCBs). Each weDAQ device provides 16 recording channels, driven right leg (DRL), a 3-axis accelerometer, local data storage, and adaptable data transmission modes. The weDAQ wireless interface supports deployment of a body area network (BAN) capable of aggregating various biosignal streams over multiple worn devices simultaneously, on the 802.11n WiFi protocol. Each channel resolves biopotentials ranging over 5 orders of magnitude with a noise level of 0.52$\mathrm{\upmu }\mathrm{V}$ $\mathrm{_{rms}}$ over a 1000-Hz bandwidth, and a peak SNDR of 119 dB and CMRR of 111 dB at 2 ksps. The device leverages in-band impedance scanning and an input multiplexer to dynamically select good skin contacting electrodes for reference and sensing channels. In-ear and forehead EEG measurements taken from subjects captured modulation of alpha brain activity, electrooculogram (EOG) characteristic eye movements, and electromyogram (EMG) from jaw muscles. Simultaneous ECG and EMG measurements were demonstrated on multiple, freely-moving subjects in their natural office environment during periods of rest and exercise. The small footprint, performance, and configurability of the open-source weDAQ platform and scalable PCB electrodes presented, aim to provide the biosensing community greater experimental flexibility and lower the barrier to entry for new health monitoring research.- 1 November 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21634025,p. 154-157
A Low-Noise, Non-Contact EEG/ECG Sensor
Typical electroencephalogram (EEG) and electrocardiogram (ECG) sensors require conductive gel to ensure low-impedance electrical contact between the sensor and skin, making set-up time-consuming and long-term recording problematic. We present a gel-free, non-contact EEG/ECG sensor with on-board electrode that capacitively couples to the skin. Active shielding of the high-impedance input significantly reduces noise pickup, and reduces variations in gain as a function of gap distance. The integrated sensor combines amplification, bandpass filtering, and analog-to-digital conversion within a 1 inch diameter enclosure. The measured input-referred noise, over 1-100 Hz frequency range, is 2μVrms at 0.2 mm sensor distance, and 17μVrms at 3.2 mm distance. Experiments coupling the sensor to human scalp through hair and to chest through clothing produce clear EEG and ECG recorded signals.
- 1 November 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21634025,p. 154-157
A Low-Noise, Non-Contact EEG/ECG Sensor
Typical electroencephalogram (EEG) and electrocardiogram (ECG) sensors require conductive gel to ensure low-impedance electrical contact between the sensor and skin, making set-up time-consuming and long-term recording problematic. We present a gel-free, non-contact EEG/ECG sensor with on-board electrode that capacitively couples to the skin. Active shielding of the high-impedance input significantly reduces noise pickup, and reduces variations in gain as a function of gap distance. The integrated sensor combines amplification, bandpass filtering, and analog-to-digital conversion within a 1 inch diameter enclosure. The measured input-referred noise, over 1-100 Hz frequency range, is 2μVrms at 0.2 mm sensor distance, and 17μVrms at 3.2 mm distance. Experiments coupling the sensor to human scalp through hair and to chest through clothing produce clear EEG and ECG recorded signals.