TBThomas Berger

Thomas Berger

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Thomas Berger has a total of 7 co-authors. Here are the top co-authors by number of shared publications:

  • Bernhard Pfeifer

    Institute of Clinical Epidemiology, Tirol Kliniken, 6020 Innsbruck, Austria

    1 shared publication
  • Florian Hintringer

    Department of Internal Medicine III, Division of Cardiology , Medical University Innsbruck , 6020 Innsbruck, Austria

    1 shared publication
  • Friedrich Hanser

    Institute of Electrical, Electronic and Bioengineering , University for Health Sciences, Medical Informatics and Technology (UMIT) , 6060 Hall i. Tirol , Austria

    1 shared publication
  • Markus Stuehlinger

    Department of Internal Medicine III, Division of Cardiology , Medical University Innsbruck , 6020 Innsbruck, Austria

    1 shared publication
  • Michael Seger

    Institute of Electrical, Electronic and Bioengineering, University for Health Sciences, Medical Informatics and Technology (UMIT), 6060 Hall i. Tirol, Austria

    1 shared publication
  • Thomas Trieb

    Department of Radiology I , Medical University Innsbruck, 6020 Innsbruck , Austria

    1 shared publication

Latest Publications

  • Open Access

    Non-invasive imaging of cardiac electrophysiology in a cardiac resynchronization therapy defibrillator patient with a quadripolar left ventricular lead

    by Michael Seger, Friedrich Hanser, Wolfgang Dichtl, Markus Stuehlinger, Florian Hintringer, Thomas Trieb, Bernhard Pfeifer, Thomas Berger

    The present study was aimed to assess epi- and endocardial ventricular electroanatomical activation during cardiac resynchronization therapy (CRT) by means of non-invasive imaging of cardiac electrophysiology (NICE) in a patient with a novel quadripolar LV lead. Non-invasive imaging of cardiac electrophysiology is a novel imaging tool which works by fusing data from high-resolution electrocardiogram (ECG) mapping with a model of the patient's individual cardiothoracic anatomy created from magnetic resonance imaging. This was performed in a cardiac resynchronization therapy defribrillator (CRT-D) patient with a quadripolar left ventricular (LV) lead. Beat-to-beat endocardial and epicardial ventricular activation sequences were computed using NICE during intrinsic conduction as well as during different pacing modes with different LV and biventricular (biV) pacing vectors. The spatial resolution of NICE enabled discrimination of the different pacing vectors during LV and biV pacing. Biventricular pacing resulted in a marked shortening of the total activation duration (TAD) of both ventricles when compared with intrinsic conduction and RV and LV pacing. Non-invasive imaging of cardiac electrophysiology facilitates non-invasive imaging of ventricular activation, which may be useful in CRT patients to locate the area of latest ventricular activation as the target area for LV lead placement. Moreover, especially in non-responders to CRT NICE may be further useful to determine the best electrical repositioning option.