Nizaj Nasimudeen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Nizaj Nasimudeen has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
Ayyappan V. Nair
Department of Orthopaedics, Manipal Whitefield Hospital, Bangalore, Karnataka, India
4 shared publications- Bipin Theruvil
Department of Orthopaedics, VPS Lakeshore Hospital, Kochi, India
4 shared publications - Jimmy Joseph Meleppuram
Department of Orthopaedics, Apollo Adlux Hospital, Cochin, Kerala, India
4 shared publications - Julio Chacko Kandathil
Department of Radiology, VPS Lakeshore Hospital, Kochi, India
4 shared publications - Prince Shanavas Khan
Department of Orthopaedics, Apollo Adlux Hospital, Kochi, Kerala, India
4 shared publications - Ajayakumar Thankappan
Department of Orthopaedics, Apollo Adlux Hospital, Cochin, Kerala, India
3 shared publications
Latest Publications
- Open Access
- 9 June 2026
- Published by Elsevier in Journal of ISAKOS
- Vol. 19, 101157
Arciero technique for anatomic posterolateral corner reconstruction of knee following femoral nailing: A current technique
- 9 June 2026
- Published by Elsevier in Journal of ISAKOS
- Vol. 19, 101157
Open AccessArciero technique for anatomic posterolateral corner reconstruction of knee following femoral nailing: A current technique
- Open Access
- 29 April 2026
- Published by Wiley in Arthroscopy Techniques
- Vol. 15 (6)
Arthroscopic Dissection and Protection of an Aberrant Suprascapular Nerve During Massive Rotator Cuff Repair
The video demonstrates an arthroscopic technique for identification, dissection, and protection of the suprascapular nerve (SSN) during massive rotator cuff repair. The SSN, closely related to the transverse scapular ligament (TSL), may present anatomical variations that heighten the risk of iatrogenic injury. In this technique, careful dissection is performed to expose the nerve, especially in cases where it courses over the TSL rather than through the suprascapular notch. Key anatomical landmarks and stepwise visualization methods are illustrated to ensure safe exposure and preservation of the SSN during procedures such as subacromial decompression, medial‐row anchor placement, massive rotator cuff tears, or SSN release. Emphasis is placed on meticulous preoperative planning and intraoperative vigilance to enhance procedural safety.
- 29 April 2026
- Published by Wiley in Arthroscopy Techniques
- Vol. 15 (6)
Open AccessArthroscopic Dissection and Protection of an Aberrant Suprascapular Nerve During Massive Rotator Cuff Repair
The video demonstrates an arthroscopic technique for identification, dissection, and protection of the suprascapular nerve (SSN) during massive rotator cuff repair. The SSN, closely related to the transverse scapular ligament (TSL), may present anatomical variations that heighten the risk of iatrogenic injury. In this technique, careful dissection is performed to expose the nerve, especially in cases where it courses over the TSL rather than through the suprascapular notch. Key anatomical landmarks and stepwise visualization methods are illustrated to ensure safe exposure and preservation of the SSN during procedures such as subacromial decompression, medial‐row anchor placement, massive rotator cuff tears, or SSN release. Emphasis is placed on meticulous preoperative planning and intraoperative vigilance to enhance procedural safety.
- Open Access
- 1 January 2026
- Published by Indian Orthopaedic Research Group in Journal of Orthopaedic Case Reports
- Vol. 16 (4) , 210-215
Pseudoaneurysm of the Medial Genicular Artery as a Rare Cause of Recurrent Knee Swelling – A Case Report
Introduction: Recurrent knee swelling in elderly or anticoagulated patients is commonly attributed to conditions, such as deep vein thrombosis (DVT), Baker’s cyst rupture, septic arthritis, or anticoagulation-related hemarthrosis. However, vascular causes, such as genicular artery pseudoaneurysm, are rare and may be overlooked, especially when symptoms persist despite appropriate treatment. Case Report: We describe a 60-year-old male with multiple comorbidities who presented with recurrent painful swelling of the right knee. Initial evaluations identified sequential pathologies, including popliteal DVT, ruptured Baker’s cyst, and septic arthritis, all treated appropriately. Despite resolution of infection and withdrawal of anticoagulation, hemarthrosis recurred. Further evaluation with Doppler ultrasonography and magnetic resonance angiography revealed a pseudoaneurysm of the superior medial genicular artery. The lesion was successfully treated using ultrasound-guided compression, resulting in complete thrombosis and resolution of symptoms without complications. Conclusion: Superior medial genicular artery pseudoaneurysm is a rare but important cause of recurrent hemarthrosis. Persistent or unexplained knee swelling should prompt early vascular imaging to avoid diagnostic delay and enable timely, minimally invasive management. Keywords: Pseudoaneurysm, genicular artery, recurrent knee swelling, hemarthrosis, ultrasound-guided compression.
- 1 January 2026
- Published by Indian Orthopaedic Research Group in Journal of Orthopaedic Case Reports
- Vol. 16 (4) , 210-215
Open AccessPseudoaneurysm of the Medial Genicular Artery as a Rare Cause of Recurrent Knee Swelling – A Case Report
Introduction: Recurrent knee swelling in elderly or anticoagulated patients is commonly attributed to conditions, such as deep vein thrombosis (DVT), Baker’s cyst rupture, septic arthritis, or anticoagulation-related hemarthrosis. However, vascular causes, such as genicular artery pseudoaneurysm, are rare and may be overlooked, especially when symptoms persist despite appropriate treatment. Case Report: We describe a 60-year-old male with multiple comorbidities who presented with recurrent painful swelling of the right knee. Initial evaluations identified sequential pathologies, including popliteal DVT, ruptured Baker’s cyst, and septic arthritis, all treated appropriately. Despite resolution of infection and withdrawal of anticoagulation, hemarthrosis recurred. Further evaluation with Doppler ultrasonography and magnetic resonance angiography revealed a pseudoaneurysm of the superior medial genicular artery. The lesion was successfully treated using ultrasound-guided compression, resulting in complete thrombosis and resolution of symptoms without complications. Conclusion: Superior medial genicular artery pseudoaneurysm is a rare but important cause of recurrent hemarthrosis. Persistent or unexplained knee swelling should prompt early vascular imaging to avoid diagnostic delay and enable timely, minimally invasive management. Keywords: Pseudoaneurysm, genicular artery, recurrent knee swelling, hemarthrosis, ultrasound-guided compression.
- 28 November 2025
- Published by Elsevier in Journal of Orthopaedics
- Vol. 72, 376-382
The biomechanical impact of glenosphere tilting, inferior translation, and humeral retroversion in reverse total shoulder arthroplasty: A 3D modelling study
- 28 November 2025
- Published by Elsevier in Journal of Orthopaedics
- Vol. 72, 376-382
The biomechanical impact of glenosphere tilting, inferior translation, and humeral retroversion in reverse total shoulder arthroplasty: A 3D modelling study
- 17 October 2025
- Published by Springer Nature in Indian Journal of Orthopaedics
- Vol. 60 (1) , 199-205
A Novel Indigenous Endoscopic-Assisted Surgery for Intractable Plantar Fasciitis: A Case Series
Background Plantar fasciitis is the most common cause of heel pain in adults, and while most cases respond to conservative treatment, a subset of patients require surgical intervention. Endoscopic plantar fascia release (EPFR) is preferred for its minimally invasive nature and favorable outcomes. However, the cost of disposable instrumentation presents a barrier in low-resource settings. This study aims to evaluate the clinical effectiveness and safety of endoscopic plantar fascia release using reusable, affordable, autoclavable instruments developed as a cost-conscious alternative to disposable kits. Methods This prospective case series included 24 patients with intractable plantar fasciitis who underwent EPFR using reusable instruments between April 2019 and March 2024. Patients were assessed preoperatively and at 12 months postoperatively using the AOFAS Hindfoot Score and the VAS for pain. Data were analyzed using paired t tests with significance set at p < 0.05. Results The mean preoperative AOFAS score improved from 59.2 ± 3.8 to 84.4 ± 6.0 postoperatively (p < .001), and the mean VAS score decreased from 8.1 ± 1.7 to 2.4 ± 0.5 (p < .001). Pain relief was reported by 91.7% of patients. No major complications were observed. Conclusion Endoscopic plantar fascia release using reusable instruments is a safe and effective surgical option, providing significant pain relief and functional improvement. The use of reusable instruments offers a practical and potentially more affordable alternative in resource-limited settings. Level of evidence: IV.
- 17 October 2025
- Published by Springer Nature in Indian Journal of Orthopaedics
- Vol. 60 (1) , 199-205
A Novel Indigenous Endoscopic-Assisted Surgery for Intractable Plantar Fasciitis: A Case Series
Background Plantar fasciitis is the most common cause of heel pain in adults, and while most cases respond to conservative treatment, a subset of patients require surgical intervention. Endoscopic plantar fascia release (EPFR) is preferred for its minimally invasive nature and favorable outcomes. However, the cost of disposable instrumentation presents a barrier in low-resource settings. This study aims to evaluate the clinical effectiveness and safety of endoscopic plantar fascia release using reusable, affordable, autoclavable instruments developed as a cost-conscious alternative to disposable kits. Methods This prospective case series included 24 patients with intractable plantar fasciitis who underwent EPFR using reusable instruments between April 2019 and March 2024. Patients were assessed preoperatively and at 12 months postoperatively using the AOFAS Hindfoot Score and the VAS for pain. Data were analyzed using paired t tests with significance set at p < 0.05. Results The mean preoperative AOFAS score improved from 59.2 ± 3.8 to 84.4 ± 6.0 postoperatively (p < .001), and the mean VAS score decreased from 8.1 ± 1.7 to 2.4 ± 0.5 (p < .001). Pain relief was reported by 91.7% of patients. No major complications were observed. Conclusion Endoscopic plantar fascia release using reusable instruments is a safe and effective surgical option, providing significant pain relief and functional improvement. The use of reusable instruments offers a practical and potentially more affordable alternative in resource-limited settings. Level of evidence: IV.
- Open Access
- 28 August 2025
- Published by Elsevier in Journal of ISAKOS
- Vol. 14, 100996
Single stage anatomic posterolateral corner reconstruction with modified LaPrade technique, combined with arthroscopic posterior cruciate ligament reconstruction with tibia nail in situ—A current technique
- 28 August 2025
- Published by Elsevier in Journal of ISAKOS
- Vol. 14, 100996
Open AccessSingle stage anatomic posterolateral corner reconstruction with modified LaPrade technique, combined with arthroscopic posterior cruciate ligament reconstruction with tibia nail in situ—A current technique
- Open Access
- 1 January 2023
- Published by Indian Orthopaedic Research Group in Journal of Orthopaedic Case Reports
- Vol. 13 (11) , 100-105
Open Intra-articular Distal Femur Fracture with 21 cm Bone Loss Managed by Early Vascularized Fibula Grafting and Antibiotic Loaded Synthetic Calcium Sulfate Beads – A Case Report
Open fractures with massive bone defect presents as challenging clinical scenario in clinical practice. If neglected, this can result in infection, non-union or severe limb length discrepancy. Autogenous vascularized fibula grafting along with stable fixation in the form of internal fixation is a viable option in such situations. Synthetic calcium sulfate is a suitable antibiotic carrier to deliver antibiotics locally to prevent infection. We report the case of an adult male who had an open fracture of the distal femur with segmental bone loss of 21 cm, managed with autogenous vascularized fibula graft and locking plates. We used antibiotic-loaded absorbable synthetic calcium sulfate beads locally during the procedure. A 52-year-old male, a known case of uncontrolled diabetes mellitus, presented to the emergency department with a comminuted open intra-articular fracture of the left distal femur with bone loss of 21 cm (arbeitsgemeinschaft fur osteosynthesefragen 33C3) following a road traffic accident. He was initially treated with meticulous debridement and internal fixation with locking compression plate. Considering the massive bone defect of 21 cm, he was planned for fibula grafting at a later stage. After 6 weeks, he underwent vascularized fibula grafting from opposite leg and an additional medial plate to stabilize the graft and augment the initial fixation. He was on regular follow-up in the outpatient department. The fracture united with no signs of infection or residual limb length discrepancy. At the latest follow-up at 7 months, he is walking independently without support and is having a functional range of knee movements. There were no post-operative complications in the right leg from where fibula was harvested. Autogenous vascularized fibula graft together with a locking compression plate is a practical choice in managing open fractures with segmental bone loss. The high concentration of local antibiotic delivery with the help of synthetic calcium sulfate beads helped prevent infection, which is the most dreaded complication associated with open fractures. In addition, the calcium sulfate beads promote endochondral ossification resulting in early bone union.
- 1 January 2023
- Published by Indian Orthopaedic Research Group in Journal of Orthopaedic Case Reports
- Vol. 13 (11) , 100-105
Open AccessOpen Intra-articular Distal Femur Fracture with 21 cm Bone Loss Managed by Early Vascularized Fibula Grafting and Antibiotic Loaded Synthetic Calcium Sulfate Beads – A Case Report
Open fractures with massive bone defect presents as challenging clinical scenario in clinical practice. If neglected, this can result in infection, non-union or severe limb length discrepancy. Autogenous vascularized fibula grafting along with stable fixation in the form of internal fixation is a viable option in such situations. Synthetic calcium sulfate is a suitable antibiotic carrier to deliver antibiotics locally to prevent infection. We report the case of an adult male who had an open fracture of the distal femur with segmental bone loss of 21 cm, managed with autogenous vascularized fibula graft and locking plates. We used antibiotic-loaded absorbable synthetic calcium sulfate beads locally during the procedure. A 52-year-old male, a known case of uncontrolled diabetes mellitus, presented to the emergency department with a comminuted open intra-articular fracture of the left distal femur with bone loss of 21 cm (arbeitsgemeinschaft fur osteosynthesefragen 33C3) following a road traffic accident. He was initially treated with meticulous debridement and internal fixation with locking compression plate. Considering the massive bone defect of 21 cm, he was planned for fibula grafting at a later stage. After 6 weeks, he underwent vascularized fibula grafting from opposite leg and an additional medial plate to stabilize the graft and augment the initial fixation. He was on regular follow-up in the outpatient department. The fracture united with no signs of infection or residual limb length discrepancy. At the latest follow-up at 7 months, he is walking independently without support and is having a functional range of knee movements. There were no post-operative complications in the right leg from where fibula was harvested. Autogenous vascularized fibula graft together with a locking compression plate is a practical choice in managing open fractures with segmental bone loss. The high concentration of local antibiotic delivery with the help of synthetic calcium sulfate beads helped prevent infection, which is the most dreaded complication associated with open fractures. In addition, the calcium sulfate beads promote endochondral ossification resulting in early bone union.
- 22 September 2022
- Published by Springer Nature in Indian Journal of Orthopaedics
- Vol. 56 (12) , 2077-2085
The Popliteal Artery is Safe in Medial Meniscal Repair Using All Inside Devices in Adults: An MRI-Based Simulation Study
Introduction This simulation study on MRI of the knee was performed to assess the risk of injury to the popliteal artery (PA) and common peroneal nerve (CPN) during all-inside meniscal repairs in adults. Methods We simulated repair of the posterior horn of both medial (PHMM) and lateral menisci (PHLM) through anteromedial (AM) and anterolateral (AL) portals, using straight and curved devices, on 200 magnetic resonance imaging (MRI) scans taken with the knee in extension. For simulation using straight devices, the shortest distance from the menisco-capsular junction (MCJ) and the free edge of the meniscus to PA and CPN in vectors of AM and AL portals was measured. In curved devices, the closest extracapsular distance from the device tip to PA was measured. Results With a straight device through AM portal, the mean distance from the MCJ of PHMM to the PA was 20.7 ± 3.15 mm (13.5–27.4). In PHMM repair through AM portal using a curved device, the mean extracapsular distance from the device tip to PA was 18.8 ± 4 mm (7.7–27.2) while pointing toward and 26 ± 4.5 mm (15.5–35.6) while pointing away from the midline. When using straight devices, the average distance from free edge of LM to PA was 18.5 ± 3.3 mm (9.6–31.2) and from MCJ to PA was 8.9 ± 2.4 mm (3.5–18.8). The average distance measured from the MCJ to CPN through AM and AL portals using straight devices was 19.4 ± 2.8 mm (10.2–32.5) and 22 ± 2.8 mm (10.4–36.7) respectively. Conclusion In adults, PA is safe in PHMM repairs using both straight and curved devices irrespective of depth and direction of insertion. In PHLM repairs, the PA is at risk with both straight and curved devices. We recommend adjusting the depth of insertion to as minimum as possible to just penetrate the capsule. The CPN is safe in LM repairs using all-inside devices. Level of Evidence Level IV.
- 22 September 2022
- Published by Springer Nature in Indian Journal of Orthopaedics
- Vol. 56 (12) , 2077-2085
The Popliteal Artery is Safe in Medial Meniscal Repair Using All Inside Devices in Adults: An MRI-Based Simulation Study
Introduction This simulation study on MRI of the knee was performed to assess the risk of injury to the popliteal artery (PA) and common peroneal nerve (CPN) during all-inside meniscal repairs in adults. Methods We simulated repair of the posterior horn of both medial (PHMM) and lateral menisci (PHLM) through anteromedial (AM) and anterolateral (AL) portals, using straight and curved devices, on 200 magnetic resonance imaging (MRI) scans taken with the knee in extension. For simulation using straight devices, the shortest distance from the menisco-capsular junction (MCJ) and the free edge of the meniscus to PA and CPN in vectors of AM and AL portals was measured. In curved devices, the closest extracapsular distance from the device tip to PA was measured. Results With a straight device through AM portal, the mean distance from the MCJ of PHMM to the PA was 20.7 ± 3.15 mm (13.5–27.4). In PHMM repair through AM portal using a curved device, the mean extracapsular distance from the device tip to PA was 18.8 ± 4 mm (7.7–27.2) while pointing toward and 26 ± 4.5 mm (15.5–35.6) while pointing away from the midline. When using straight devices, the average distance from free edge of LM to PA was 18.5 ± 3.3 mm (9.6–31.2) and from MCJ to PA was 8.9 ± 2.4 mm (3.5–18.8). The average distance measured from the MCJ to CPN through AM and AL portals using straight devices was 19.4 ± 2.8 mm (10.2–32.5) and 22 ± 2.8 mm (10.4–36.7) respectively. Conclusion In adults, PA is safe in PHMM repairs using both straight and curved devices irrespective of depth and direction of insertion. In PHLM repairs, the PA is at risk with both straight and curved devices. We recommend adjusting the depth of insertion to as minimum as possible to just penetrate the capsule. The CPN is safe in LM repairs using all-inside devices. Level of Evidence Level IV.
- 1 January 2022
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 12 (1)
Double Level Osteotomy in an Overcorrected Distal Femoral Varisation Osteotomy
Case: We report a patient who was diagnosed with idiopathic genu valgum at the age of 11 years and underwent bilateral distal femur osteotomies. At age 30 years, she presented with pain around her right knee with a varus deformity. Although the corrective osteotomy was at the distal femur, she was noticed to have a bifocal deformity in both femur and tibia. She was managed with single-stage osteotomies at the distal femur and proximal tibia. Conclusion: This case report highlights the importance of preoperative analysis to identify the site of deformity. In bifocal pathology, a 2-level osteotomy is required to prevent an oblique joint line.
- 1 January 2022
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 12 (1)
Double Level Osteotomy in an Overcorrected Distal Femoral Varisation Osteotomy
Case: We report a patient who was diagnosed with idiopathic genu valgum at the age of 11 years and underwent bilateral distal femur osteotomies. At age 30 years, she presented with pain around her right knee with a varus deformity. Although the corrective osteotomy was at the distal femur, she was noticed to have a bifocal deformity in both femur and tibia. She was managed with single-stage osteotomies at the distal femur and proximal tibia. Conclusion: This case report highlights the importance of preoperative analysis to identify the site of deformity. In bifocal pathology, a 2-level osteotomy is required to prevent an oblique joint line.