John Ryan Martin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
John Ryan Martin has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
- Aleksander P. Mika
Department of Orthopedic Surgery, Vanderbilt University Medical Center, Nashville, Tennessee
5 shared publications Gregory G. Polkowski
Department of Orthopaedics, Vanderbilt University Medical Center, Nashville, TN, USA
5 shared publications- Jacob M. Wilson
Emory University School of Medicine, Atlanta, GA, USA
4 shared publications - Gregory G. Polkowski
Vanderbilt University Medical Center
3 shared publications Stephen M. Engstrom
Vanderbilt University Medical Center, Nashville, Tennessee, USA
3 shared publicationsAndrew A. Shinar
Department of Orthopedics, Vanderbilt University Medical Center, Nashville, Tennessee
2 shared publications
Latest Publications
- Open Access
- 3 August 2026
- Published by Wolters Kluwer Health in Journal of the American Academy of Orthopaedic Surgeons
- Vol. 34 (23) , e3441-e3450
Aligning Success: Insights From 85,000 CT Scans on Trochlear Groove Positioning With Kinematic Alignment
Background: Patellar maltracking remains a notable cause of postoperative pain and dissatisfaction after total knee arthroplasty (TKA), often from femoral component internal rotation and trochlear groove (TG) malpositioning. Although the Coronal Plane Alignment of the Knee (CPAK) classification evaluates coronal alignment, it does not account for three-dimensional anatomy. As newer alignment philosophies like kinematic alignment (KA) gain traction, risk of patellar maltracking may increase, especially when using implants designed for mechanical alignment. This study evaluates TG orientation in axial and coronal planes after virtual KA-based placement of a standard femoral component in 85,604 patients undergoing primary TKA. Methods: We analyzed 85,604 CT scans of patients with arthritis. For each, we calculated CPAK classification, lateral distal femoral angle (LDFA), medial proximal tibial angle (MPTA), hip-knee-ankle (HKA) angle, and posterior condylar to transepicondylar axis (PCA to TEA). Using kinematic alignment principles, we virtually implanted a femoral component with a 6° lateral trochlear groove. The average quadriceps line of force (QLF), defined as 3.2° lateral to the femoral mechanical axis (FMA), was considered ideal for tracking. TG orientation was then measured relative to the QLF and the standard 6° reference point. Results: Mean values were as follows: LDFA 87.1°, MPTA 85.7°, HKA 176.7°, and PCA to TEA 3.2°. In the coronal plane, 41% had a TG medial to the QLF, and 9% of cases had a TG medial to the native MA. CPAK types 2 (74%), 3 (100%), and 6 (58%) showed the highest internal rotation and medial TG orientation. To achieve KA, approximately 30% of patients required >3° of internal rotation and valgus tilt and approximately 2% required >5°. Conclusion: A large proportion of patients demonstrated TG malpositioning and excessive internal rotation when placing MA-designed implants in KA. This highlights the need for three-dimensional classification systems and alignment-specific designs or alignment guardrails to prevent implant malpositioning.
- 3 August 2026
- Published by Wolters Kluwer Health in Journal of the American Academy of Orthopaedic Surgeons
- Vol. 34 (23) , e3441-e3450
Open AccessAligning Success: Insights From 85,000 CT Scans on Trochlear Groove Positioning With Kinematic Alignment
Background: Patellar maltracking remains a notable cause of postoperative pain and dissatisfaction after total knee arthroplasty (TKA), often from femoral component internal rotation and trochlear groove (TG) malpositioning. Although the Coronal Plane Alignment of the Knee (CPAK) classification evaluates coronal alignment, it does not account for three-dimensional anatomy. As newer alignment philosophies like kinematic alignment (KA) gain traction, risk of patellar maltracking may increase, especially when using implants designed for mechanical alignment. This study evaluates TG orientation in axial and coronal planes after virtual KA-based placement of a standard femoral component in 85,604 patients undergoing primary TKA. Methods: We analyzed 85,604 CT scans of patients with arthritis. For each, we calculated CPAK classification, lateral distal femoral angle (LDFA), medial proximal tibial angle (MPTA), hip-knee-ankle (HKA) angle, and posterior condylar to transepicondylar axis (PCA to TEA). Using kinematic alignment principles, we virtually implanted a femoral component with a 6° lateral trochlear groove. The average quadriceps line of force (QLF), defined as 3.2° lateral to the femoral mechanical axis (FMA), was considered ideal for tracking. TG orientation was then measured relative to the QLF and the standard 6° reference point. Results: Mean values were as follows: LDFA 87.1°, MPTA 85.7°, HKA 176.7°, and PCA to TEA 3.2°. In the coronal plane, 41% had a TG medial to the QLF, and 9% of cases had a TG medial to the native MA. CPAK types 2 (74%), 3 (100%), and 6 (58%) showed the highest internal rotation and medial TG orientation. To achieve KA, approximately 30% of patients required >3° of internal rotation and valgus tilt and approximately 2% required >5°. Conclusion: A large proportion of patients demonstrated TG malpositioning and excessive internal rotation when placing MA-designed implants in KA. This highlights the need for three-dimensional classification systems and alignment-specific designs or alignment guardrails to prevent implant malpositioning.
- Open Access
- 1 January 2026
- Published by Wolters Kluwer Health in JBJS Open Access
- Vol. 11 (1)
Early Conversion Total Hip Arthroplasty for High-Energy Acetabular Fractures Is Associated With Poor Outcomes
Background: Conversion total hip arthroplasty (THA) is performed as a salvage operation for patients who develop symptomatic posttraumatic arthritis following open reduction internal fixation (ORIF) of displaced acetabular fractures. Historically, high failure rates in this patient population were related to acetabular loosening. Recent studies, however, have demonstrated improved outcomes with modern techniques. This study aims to evaluate the outcomes and survivorship of early conversion THA after high-energy acetabular fractures at our institution. Methods: A retrospective review was performed of all patients who underwent acetabular ORIF and subsequent conversion THA at a Level I trauma center between 2002 and 2022. Patients with less than 1 year follow-up after conversion THA without complication were excluded. Patient demographics, injury characteristics, perioperative details of ORIF and THA, complications, and subsequent reoperations and revisions were recorded. Results: A total of 144 cases were included. The average age was 51.3 years at the time of ORIF with transverse posterior wall (46.5%) and posterior wall (30.6%) fracture patterns predominating. The median time from ORIF to conversion THA was 1.1 years (interquartile range [IQR], 0.7-1.8). Complications occurred in 47 THAs (32.6%), with dislocation (n = 19, 13.2%) and periprosthetic joint infection (n = 17, 11.8%) being the most common. The reoperation and revision rate following conversion THA was 21.5% and 18.1%, respectively. The median time from conversion THA to revision THA was 0.5 years (IQR, 0.1-1.3), with 69.2% of revisions occurring within the first year. Conclusions: Early conversion THA following acetabular ORIF in our cohort was associated with a marked rate of complication and revision surgery. Although aseptic loosening was less prevalent, instability and infection rates were significant concerns. These findings underscore the need for continued improvements in managing this challenging patient population. Level of Evidence: Level III . See Instructions for Authors for a complete description of levels of evidence.
- 1 January 2026
- Published by Wolters Kluwer Health in JBJS Open Access
- Vol. 11 (1)
Open AccessEarly Conversion Total Hip Arthroplasty for High-Energy Acetabular Fractures Is Associated With Poor Outcomes
Background: Conversion total hip arthroplasty (THA) is performed as a salvage operation for patients who develop symptomatic posttraumatic arthritis following open reduction internal fixation (ORIF) of displaced acetabular fractures. Historically, high failure rates in this patient population were related to acetabular loosening. Recent studies, however, have demonstrated improved outcomes with modern techniques. This study aims to evaluate the outcomes and survivorship of early conversion THA after high-energy acetabular fractures at our institution. Methods: A retrospective review was performed of all patients who underwent acetabular ORIF and subsequent conversion THA at a Level I trauma center between 2002 and 2022. Patients with less than 1 year follow-up after conversion THA without complication were excluded. Patient demographics, injury characteristics, perioperative details of ORIF and THA, complications, and subsequent reoperations and revisions were recorded. Results: A total of 144 cases were included. The average age was 51.3 years at the time of ORIF with transverse posterior wall (46.5%) and posterior wall (30.6%) fracture patterns predominating. The median time from ORIF to conversion THA was 1.1 years (interquartile range [IQR], 0.7-1.8). Complications occurred in 47 THAs (32.6%), with dislocation (n = 19, 13.2%) and periprosthetic joint infection (n = 17, 11.8%) being the most common. The reoperation and revision rate following conversion THA was 21.5% and 18.1%, respectively. The median time from conversion THA to revision THA was 0.5 years (IQR, 0.1-1.3), with 69.2% of revisions occurring within the first year. Conclusions: Early conversion THA following acetabular ORIF in our cohort was associated with a marked rate of complication and revision surgery. Although aseptic loosening was less prevalent, instability and infection rates were significant concerns. These findings underscore the need for continued improvements in managing this challenging patient population. Level of Evidence: Level III . See Instructions for Authors for a complete description of levels of evidence.
- 11 November 2025
- Published by Springer Nature
- p. 97-113
Enhancing Segmentation Fairness Through Curriculum Learning and Progressive Loss: Segmentation of Hip and Knee Radiographs
- 11 November 2025
- Published by Springer Nature
- p. 97-113
Enhancing Segmentation Fairness Through Curriculum Learning and Progressive Loss: Segmentation of Hip and Knee Radiographs
- Open Access
- 7 August 2025
- Published by Elsevier in Arthroplasty Today
- Vol. 34, 101778
Femoral Component Loosening is the Predominant Mode of Early Failure in Contemporary Cementless Total Knee Arthroplasty
- 7 August 2025
- Published by Elsevier in Arthroplasty Today
- Vol. 34, 101778
Open AccessFemoral Component Loosening is the Predominant Mode of Early Failure in Contemporary Cementless Total Knee Arthroplasty
- 17 December 2024
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 185, 109571
Novel dilation-erosion labeling technique allows for rapid, accurate and adjustable alignment measurements in primary TKA
- 17 December 2024
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 185, 109571
Novel dilation-erosion labeling technique allows for rapid, accurate and adjustable alignment measurements in primary TKA
- Open Access
- 17 October 2024
- Published by Elsevier in Arthroplasty Today
- Vol. 30, 101476
Cement Viscosity and Application Time Lead to Significant Changes in Cement Penetration and Contact Surface Area
- 17 October 2024
- Published by Elsevier in Arthroplasty Today
- Vol. 30, 101476
Open AccessCement Viscosity and Application Time Lead to Significant Changes in Cement Penetration and Contact Surface Area
- Open Access
- 18 July 2024
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 5 (7) , 592-600
Tibial insert design significantly alters knee kinematics using a single cruciate-retaining total knee implant
Aims: Patient dissatisfaction is not uncommon following primary total knee arthroplasty. One proposed method to alleviate this is by improving knee kinematics. Therefore, we aimed to answer the following research question: are there significant differences in knee kinematics based on the design of the tibial insert (cruciate-retaining (CR), ultra-congruent (UC), or medial congruent (MC))?Methods: Overall, 15 cadaveric knee joints were examined with a CR implant with three different tibial inserts (CR, UC, and MC) using an established knee joint simulator. The effects on coronal alignment, medial and lateral femoral roll back, femorotibial rotation, bony rotations (femur, tibia, and patella), and patellofemoral length ratios were determined.Results: No statistically significant differences were found regarding coronal alignment (p = 0.087 to p = 0.832). The medial congruent insert demonstrated restricted femoral roll back (mean medial 37.57 mm; lateral 36.34 mm), while the CR insert demonstrated the greatest roll back (medial 42.21 mm; lateral 37.88 mm; p < 0.001, respectively). Femorotibial rotation was greatest with the CR insert with 2.45° (SD 4.75°), then the UC insert with 1.31° (SD 4.15°; p < 0.001), and lowest with the medial congruent insert with 0.8° (SD 4.24°; p < 0.001). The most pronounced patella shift, but lowest patellar rotation, was noted with the CR insert.Conclusion: The MC insert demonstrated the highest level of constraint of these inserts. Femoral roll back, femorotibial rotation, and single bony rotations were lowest with the MC insert. The patella showed less shifting with the MC insert, but there was significantly increased rotation. While the medial congruent insert was found to have highest constraint, it remains uncertain if this implant recreates native knee kinematics or if this will result in improved patient satisfaction.Cite this article: Bone Jt Open 2024;5(7):592–600.
- 18 July 2024
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 5 (7) , 592-600
Open AccessTibial insert design significantly alters knee kinematics using a single cruciate-retaining total knee implant
Aims: Patient dissatisfaction is not uncommon following primary total knee arthroplasty. One proposed method to alleviate this is by improving knee kinematics. Therefore, we aimed to answer the following research question: are there significant differences in knee kinematics based on the design of the tibial insert (cruciate-retaining (CR), ultra-congruent (UC), or medial congruent (MC))?Methods: Overall, 15 cadaveric knee joints were examined with a CR implant with three different tibial inserts (CR, UC, and MC) using an established knee joint simulator. The effects on coronal alignment, medial and lateral femoral roll back, femorotibial rotation, bony rotations (femur, tibia, and patella), and patellofemoral length ratios were determined.Results: No statistically significant differences were found regarding coronal alignment (p = 0.087 to p = 0.832). The medial congruent insert demonstrated restricted femoral roll back (mean medial 37.57 mm; lateral 36.34 mm), while the CR insert demonstrated the greatest roll back (medial 42.21 mm; lateral 37.88 mm; p < 0.001, respectively). Femorotibial rotation was greatest with the CR insert with 2.45° (SD 4.75°), then the UC insert with 1.31° (SD 4.15°; p < 0.001), and lowest with the medial congruent insert with 0.8° (SD 4.24°; p < 0.001). The most pronounced patella shift, but lowest patellar rotation, was noted with the CR insert.Conclusion: The MC insert demonstrated the highest level of constraint of these inserts. Femoral roll back, femorotibial rotation, and single bony rotations were lowest with the MC insert. The patella showed less shifting with the MC insert, but there was significantly increased rotation. While the medial congruent insert was found to have highest constraint, it remains uncertain if this implant recreates native knee kinematics or if this will result in improved patient satisfaction.Cite this article: Bone Jt Open 2024;5(7):592–600.
- Open Access
- 29 May 2024
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 39 (11) , 2669-2674.e1
Is a Failed Spinal Attempt Associated With a Worse Clinical Course Following Primary Total Hip and Knee Arthroplasty?
- 29 May 2024
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 39 (11) , 2669-2674.e1
Open AccessIs a Failed Spinal Attempt Associated With a Worse Clinical Course Following Primary Total Hip and Knee Arthroplasty?
- 1 January 2024
- Vol. 44 (2) , 44-48
Coronal Malalignment Is Infrequently Present in Patients With Aseptic Tibial Loosening
Coronal lower extremity malalignment and improper implant position have been described as risk factors for aseptic tibial loosening following primary total knee arthroplasty (TKA). However, several prior studies have shown no association between alignment and implant loosening. Meanwhile, there is increasing interest in kinematic alignment. Therefore, we sought to determine the incidence of coronal malalignment of the limb and tibial component in patients that were revised secondary to aseptic tibial loosening. A cohort of 73 patients that were revised for aseptic tibial loosening was identified. Patient demographics were recorded. Radiographs from the primary procedure (preoperative and postoperative) were reviewed to determine the index coronal alignment of the knee and tibial component. Adequate alignment was noted if limb alignment was in neutral or appropriate valgus alignment and tibial implant position was within 3° of the neutral mechanical axis. Four (5.5%) patients had varus alignment of the tibial component >3°. Therefore, 69/73 (94.5%) patients had well-aligned tibial implants. The average coronal alignment of the limb was 3° of valgus and six (8.2%) patients had coronal varus limb alignment (all >0° anatomic varus). Limb and tibial implant malalignment were infrequently seen in patients revised secondary to aseptic tibial loosening. Most patients fell within previously described “safe” alignment parameters (<3° varus for the tibial component and neutral or valgus limb alignment). Specifically, malalignment was only present in approximately six to eight percent of patients. Therefore, factors other than alignment appear to contribute most to the development of aseptic tibial loosening. Level of Evidence: III
- 1 January 2024
- Vol. 44 (2) , 44-48
Coronal Malalignment Is Infrequently Present in Patients With Aseptic Tibial Loosening
Coronal lower extremity malalignment and improper implant position have been described as risk factors for aseptic tibial loosening following primary total knee arthroplasty (TKA). However, several prior studies have shown no association between alignment and implant loosening. Meanwhile, there is increasing interest in kinematic alignment. Therefore, we sought to determine the incidence of coronal malalignment of the limb and tibial component in patients that were revised secondary to aseptic tibial loosening. A cohort of 73 patients that were revised for aseptic tibial loosening was identified. Patient demographics were recorded. Radiographs from the primary procedure (preoperative and postoperative) were reviewed to determine the index coronal alignment of the knee and tibial component. Adequate alignment was noted if limb alignment was in neutral or appropriate valgus alignment and tibial implant position was within 3° of the neutral mechanical axis. Four (5.5%) patients had varus alignment of the tibial component >3°. Therefore, 69/73 (94.5%) patients had well-aligned tibial implants. The average coronal alignment of the limb was 3° of valgus and six (8.2%) patients had coronal varus limb alignment (all >0° anatomic varus). Limb and tibial implant malalignment were infrequently seen in patients revised secondary to aseptic tibial loosening. Most patients fell within previously described “safe” alignment parameters (<3° varus for the tibial component and neutral or valgus limb alignment). Specifically, malalignment was only present in approximately six to eight percent of patients. Therefore, factors other than alignment appear to contribute most to the development of aseptic tibial loosening. Level of Evidence: III
- 1 January 2024
- Published by Wolters Kluwer Health in JBJS Reviews
- Vol. 12 (1)
Glucagon-like Peptide-1 Agonists
» Orthopaedic surgeons are increasingly likely to encounter patients with obesity and/or type 2 diabetes taking glucagon-like peptide-1 (GLP-1) agonists for weight loss. » GLP-1 agonists are an effective treatment for weight loss with semaglutide and tirzepatide being the most effective agents. Randomized controlled trials using these agents have reported weight loss up to 21 kg (46 lb). » The use of GLP-1 agonists preoperatively can improve glycemic control, which can potentially reduce the risk of postoperative complications. However, multiple cases of intraoperative aspiration/regurgitation have been reported, potentially related to the effect of GLP-1 agonists on gastric emptying. » While efficacious, GLP-1 agonists may not produce sufficient weight loss to achieve body mass index cutoffs for total joint arthroplasty depending on individual patient factors, including starting bodyweight. Multifactorial approaches to weight loss with focus on lifestyle modification in addition to GLP-1 agonists should be considered in such patients. » Although GLP-1 agonists are efficacious agents for weight loss, they may not be accessible or affordable for all patients. Each patient's unique circumstances should be considered when creating an ideal weight loss plan during optimization efforts.
- 1 January 2024
- Published by Wolters Kluwer Health in JBJS Reviews
- Vol. 12 (1)
Glucagon-like Peptide-1 Agonists
» Orthopaedic surgeons are increasingly likely to encounter patients with obesity and/or type 2 diabetes taking glucagon-like peptide-1 (GLP-1) agonists for weight loss. » GLP-1 agonists are an effective treatment for weight loss with semaglutide and tirzepatide being the most effective agents. Randomized controlled trials using these agents have reported weight loss up to 21 kg (46 lb). » The use of GLP-1 agonists preoperatively can improve glycemic control, which can potentially reduce the risk of postoperative complications. However, multiple cases of intraoperative aspiration/regurgitation have been reported, potentially related to the effect of GLP-1 agonists on gastric emptying. » While efficacious, GLP-1 agonists may not produce sufficient weight loss to achieve body mass index cutoffs for total joint arthroplasty depending on individual patient factors, including starting bodyweight. Multifactorial approaches to weight loss with focus on lifestyle modification in addition to GLP-1 agonists should be considered in such patients. » Although GLP-1 agonists are efficacious agents for weight loss, they may not be accessible or affordable for all patients. Each patient's unique circumstances should be considered when creating an ideal weight loss plan during optimization efforts.