S J Nik
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
S J Nik has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
A P H Butler
Centre of Bioengineering, Christchurch School of Medicine, 2 Riccarton Avenue, Christchurch 8011, New Zealand
1 shared publicationB Currie
Medical Physics and Bioengineering Department, Christchurch Hospital, 2 Riccarton Avenue, Christchurch 4710, New Zealand
1 shared publicationJ P Ronaldson
Centre of Bioengineering, Christchurch School of Medicine, 2 Riccarton Avenue, Christchurch 8011, New Zealand
1 shared publication- Juergen Meyer
Department of Radiation Oncology, Fred Hutchinson Cancer Center University of Washington Seattle Washington USA
1 shared publication M F Walsh
Centre of Bioengineering, Christchurch School of Medicine, 2 Riccarton Avenue, Christchurch 8011, New Zealand
1 shared publicationP H Butler
Department of Physics and Astronomy, University of Canterbury, Private Bag 4800, Christchurch 8140, New Zealand
1 shared publication
Latest Publications
- 1 August 2014
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 9 (08) , T08003
Monte Carlo validation of optimal material discrimination using spectral x-ray imaging
The aim of this work was to develop a framework to validate an algorithm for determination of optimal material discrimination in spectral x-ray imaging. Using Monte Carlo (MC) simulations based on the BEAMnrc package, material decomposition was performed on the projection images of phantoms containing up to three materials. The simulated projection data was first decomposed into material basis images by minimizing the z-score between expected and simulated counts. Statistical analysis was performed for the pixels within the region-of-interest consisting of contrast material(s) in the MC simulations. With the consideration of scattered radiation and a realistic scanning geometry, the theoretical optima of energy bin borders provided by the algorithm were shown to have an accuracy of ±2 keV for the decomposition of 2 and 3 materials. Finally, the signal-to-noise ratio predicted by the theoretical model was also validated. The counts per pixel needed for achieving a specific imaging aim can therefore be estimated using the validated model.
- 1 August 2014
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 9 (08) , T08003
Monte Carlo validation of optimal material discrimination using spectral x-ray imaging
The aim of this work was to develop a framework to validate an algorithm for determination of optimal material discrimination in spectral x-ray imaging. Using Monte Carlo (MC) simulations based on the BEAMnrc package, material decomposition was performed on the projection images of phantoms containing up to three materials. The simulated projection data was first decomposed into material basis images by minimizing the z-score between expected and simulated counts. Statistical analysis was performed for the pixels within the region-of-interest consisting of contrast material(s) in the MC simulations. With the consideration of scattered radiation and a realistic scanning geometry, the theoretical optima of energy bin borders provided by the algorithm were shown to have an accuracy of ±2 keV for the decomposition of 2 and 3 materials. Finally, the signal-to-noise ratio predicted by the theoretical model was also validated. The counts per pixel needed for achieving a specific imaging aim can therefore be estimated using the validated model.
- 1 November 2012
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 7 (11) , C11004
Spectrum measurement using Medipix3 in Charge Summing Mode
We have obtained first spectrum measurements on a Medipix3 detector with a cadmium telluride (CdTe) sensor using Charge Summing Mode (CSM). It will be shown that CSM in Medipix3 is capable of reducing the adverse effects of charge sharing and fluorescent x-rays of CdTe on the spectra recorded. The development of the Medipix All Resolution System (MARS) x-ray camera has allowed us to explore this novel pixel communication feature in Medipix3. Spectrum measurements in this work were carried out using a MARS camera consisting of a Medipix3 chip bump-bonded to a 1mm thick CdTe sensor layer. The characteristic peaks of the Am-241 source as well as the spectroscopic properties of the CdTe sensor material were depicted at a spatial resolution of 55 μm. Furthermore, a "connected component" algorithm shows a silicon based Medipix3 is effective in reallocating spread charge into a single pixel.
- 1 November 2012
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 7 (11) , C11004
Spectrum measurement using Medipix3 in Charge Summing Mode
We have obtained first spectrum measurements on a Medipix3 detector with a cadmium telluride (CdTe) sensor using Charge Summing Mode (CSM). It will be shown that CSM in Medipix3 is capable of reducing the adverse effects of charge sharing and fluorescent x-rays of CdTe on the spectra recorded. The development of the Medipix All Resolution System (MARS) x-ray camera has allowed us to explore this novel pixel communication feature in Medipix3. Spectrum measurements in this work were carried out using a MARS camera consisting of a Medipix3 chip bump-bonded to a 1mm thick CdTe sensor layer. The characteristic peaks of the Am-241 source as well as the spectroscopic properties of the CdTe sensor material were depicted at a spatial resolution of 55 μm. Furthermore, a "connected component" algorithm shows a silicon based Medipix3 is effective in reallocating spread charge into a single pixel.