Yifan Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yifan Chen has a total of 220 co-authors. Here are the top co-authors by number of shared publications:
Zhengda Li
State Key Laboratory of Infrared Physics, Shanghai Institute of Technical Physics, Chinese Academy of Sciences 1 , Yutian Road, Shanghai 200083
4 shared publicationsChen Zhang
National Astronomical Observatories, Chinese Academy of Sciences 2 , Datun Road, Beijing 100012
3 shared publicationsChengbin Wang
State Key Laboratory of Infrared Physics, Shanghai Institute of Technical Physics, Chinese Academy of Sciences 1 , Yutian Road, Shanghai 200083
3 shared publicationsHuaqing Cheng
National Astronomical Observatories, Chinese Academy of Sciences 2 , Datun Road, Beijing 100012
2 shared publicationsWei Fu
State Key Laboratory of Infrared Physics, Shanghai Institute of Technical Physics, Chinese Academy of Sciences 1 , Yutian Road, Shanghai 200083
2 shared publicationsXiaohao Ma
State Key Laboratory of Infrared Physics, Shanghai Institute of Technical Physics, Chinese Academy of Sciences 1 , Yutian Road, Shanghai 200083
2 shared publications
Latest Publications
- Open Access
- 1 January 2026
- Published by AIP Publishing in AIP Advances
- Vol. 16 (1)
Offline assembly of the lobster-eye x-ray telescope based on optical reference transfer
To address the difficulty of focal alignment and optical axis calibration of lobster-eye x-ray telescopes in the absence of an x-ray vacuum environment, an offline visible-light alignment method based on optical reference transfer under atmospheric conditions is proposed. The detector assembly consists of four complementary metal oxide semiconductor (CMOS) sensors assembled into a quasi-spherical focal surface. By monitoring the optical markers, the position and orientation of each CMOS sensor are finely adjusted to achieve precise matching between the imaging surface and the focal plane. Cube mirrors are mounted on both the detector and optical assemblies, enabling accurate optical axis and focal plane alignment using theodolites and a laser tracker. Test results show that after alignment, the angular resolution of the system exhibits less than 5.36% variation compared to component-level tests, and the field-of-view shows less than 0.1% change. These results verify the high precision and feasibility of the proposed alignment method, providing an effective technical approach for ground-based integration of wide-field x-ray telescopes.
- 1 January 2026
- Published by AIP Publishing in AIP Advances
- Vol. 16 (1)
Open AccessOffline assembly of the lobster-eye x-ray telescope based on optical reference transfer
To address the difficulty of focal alignment and optical axis calibration of lobster-eye x-ray telescopes in the absence of an x-ray vacuum environment, an offline visible-light alignment method based on optical reference transfer under atmospheric conditions is proposed. The detector assembly consists of four complementary metal oxide semiconductor (CMOS) sensors assembled into a quasi-spherical focal surface. By monitoring the optical markers, the position and orientation of each CMOS sensor are finely adjusted to achieve precise matching between the imaging surface and the focal plane. Cube mirrors are mounted on both the detector and optical assemblies, enabling accurate optical axis and focal plane alignment using theodolites and a laser tracker. Test results show that after alignment, the angular resolution of the system exhibits less than 5.36% variation compared to component-level tests, and the field-of-view shows less than 0.1% change. These results verify the high precision and feasibility of the proposed alignment method, providing an effective technical approach for ground-based integration of wide-field x-ray telescopes.
- 23 July 2025
- Published by Optica Publishing Group in Applied Optics
- Vol. 64 (22) , 6405-6410
Visible light blocking performance of a wide-field X-ray telescope onboard the Einstein probe
The wide-field X-ray telescope (WXT) onboard the Einstein probe (EP) is equipped with complementary metal-oxide semiconductor (CMOS) detector that is sensitive not only to X-rays but also to visible light. Therefore, effective visible light blocking is crucial to prevent interference with X-ray performance. In this paper, we present the design of the blocking films and the baffle for the WXT module and simulate the blocking performance on visible light. The visible light transmittance of the two film combinations is less than 10−14 orders of magnitude. When the angle of incident light is beyond the field of view, the intensity is rapidly reduced by more than six times. We conducted experiments to test the out-of-field visible light blocking performance using a customized WXT module, and the measured results were in good agreement with the simulated results. On this basis, we calculated that when the EP satellite is operating in orbit, the reflected light from the Earth in the field of view would cause no significant response from the CMOS detectors. The on-orbit test results of the EP satellite verified our analysis, demonstrating that the WXT module has a good visible light blocking performance.
- 23 July 2025
- Published by Optica Publishing Group in Applied Optics
- Vol. 64 (22) , 6405-6410
Visible light blocking performance of a wide-field X-ray telescope onboard the Einstein probe
The wide-field X-ray telescope (WXT) onboard the Einstein probe (EP) is equipped with complementary metal-oxide semiconductor (CMOS) detector that is sensitive not only to X-rays but also to visible light. Therefore, effective visible light blocking is crucial to prevent interference with X-ray performance. In this paper, we present the design of the blocking films and the baffle for the WXT module and simulate the blocking performance on visible light. The visible light transmittance of the two film combinations is less than 10−14 orders of magnitude. When the angle of incident light is beyond the field of view, the intensity is rapidly reduced by more than six times. We conducted experiments to test the out-of-field visible light blocking performance using a customized WXT module, and the measured results were in good agreement with the simulated results. On this basis, we calculated that when the EP satellite is operating in orbit, the reflected light from the Earth in the field of view would cause no significant response from the CMOS detectors. The on-orbit test results of the EP satellite verified our analysis, demonstrating that the WXT module has a good visible light blocking performance.
- Top Cited Papers
- 23 January 2025
- Published by Springer Nature in Nature Astronomy
- Vol. 9 (4) , 564-576
Soft X-ray prompt emission from the high-redshift gamma-ray burst EP240315a
- 23 January 2025
- Published by Springer Nature in Nature Astronomy
- Vol. 9 (4) , 564-576
Top Cited PapersSoft X-ray prompt emission from the high-redshift gamma-ray burst EP240315a
- 16 August 2023
- Published by Optica Publishing Group in Applied Optics
- Vol. 62 (24) , 6472-6479
Design and preliminary evaluation of a multi-channel multi-energy point integrated Wolter microscope
In inertial confinement fusion, high-precision x-ray imaging is crucial for understanding the states of matter under extreme conditions. To observe the target asymmetry during compression, multiple imaging spots with varying energy responses are necessary. However, integrating multiple imaging channels in a grazing incidence x-ray imaging scheme is challenging, and there is an urgent need for effective combination of multi-color and high-throughput diagnostics. This study presents a design method for a multi-channel integrated Wolter microscope with high spatial resolution, wide-band response, and high throughput. The basic optical configuration, adjustment method, and multi-channel integration scheme are discussed in detail. A 10 keV-class three-channel integrated Wolter microscope is proposed for verification, with an estimated spatial resolution better than 4.0 µm in a field of view of ±500µm. The peak response efficiencies for each imaging channel are calculated as 5.2×10−5sr, 8.6×10−5sr, and 2.2×10−4sr, respectively.
- 16 August 2023
- Published by Optica Publishing Group in Applied Optics
- Vol. 62 (24) , 6472-6479
Design and preliminary evaluation of a multi-channel multi-energy point integrated Wolter microscope
In inertial confinement fusion, high-precision x-ray imaging is crucial for understanding the states of matter under extreme conditions. To observe the target asymmetry during compression, multiple imaging spots with varying energy responses are necessary. However, integrating multiple imaging channels in a grazing incidence x-ray imaging scheme is challenging, and there is an urgent need for effective combination of multi-color and high-throughput diagnostics. This study presents a design method for a multi-channel integrated Wolter microscope with high spatial resolution, wide-band response, and high throughput. The basic optical configuration, adjustment method, and multi-channel integration scheme are discussed in detail. A 10 keV-class three-channel integrated Wolter microscope is proposed for verification, with an estimated spatial resolution better than 4.0 µm in a field of view of ±500µm. The peak response efficiencies for each imaging channel are calculated as 5.2×10−5sr, 8.6×10−5sr, and 2.2×10−4sr, respectively.
- 5 October 2022
- Published by Optica Publishing Group in Applied Optics
- Vol. 61 (29) , 8813-8818
Detection system of the lobster eye telescope with large field of view
The lobster eye telescope is promising for large-field x ray imaging in astronomy. The special structure of the lobster eye system makes the focal plane a sphere, resulting in detector defocus when the field is large. In this study, we established a model based on the principle of lobster eye imaging and simulated the imaging at different image distances. The results reveal the relationship between the defocus and position accuracy and angular resolution. To ensure the optical performance of the large field lobster eye telescope, we propose a detection system design method using multiple detectors stitched together to form a spherical-like surface and apply it to the development of the Einstein Probe/wide-field x ray telescope (EP/WXT) submodule. About 70% of the detection area is out of focus within 0.5 mm. The scanning image of the integrated WXT submodule shows good uniformity of the point spread function (PSF) for various incident angles, and the effect of defocus on imaging is acceptable.
- 5 October 2022
- Published by Optica Publishing Group in Applied Optics
- Vol. 61 (29) , 8813-8818
Detection system of the lobster eye telescope with large field of view
The lobster eye telescope is promising for large-field x ray imaging in astronomy. The special structure of the lobster eye system makes the focal plane a sphere, resulting in detector defocus when the field is large. In this study, we established a model based on the principle of lobster eye imaging and simulated the imaging at different image distances. The results reveal the relationship between the defocus and position accuracy and angular resolution. To ensure the optical performance of the large field lobster eye telescope, we propose a detection system design method using multiple detectors stitched together to form a spherical-like surface and apply it to the development of the Einstein Probe/wide-field x ray telescope (EP/WXT) submodule. About 70% of the detection area is out of focus within 0.5 mm. The scanning image of the integrated WXT submodule shows good uniformity of the point spread function (PSF) for various incident angles, and the effect of defocus on imaging is acceptable.