Christian M. Puttlitz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Christian M. Puttlitz has a total of 82 co-authors. Here are the top co-authors by number of shared publications:
Kirk C. McGilvray
Orthopaedic Bioengineering Research Laboratory, Department of Mechanical Engineering and School of Biomedical Engineering, Colorado State University, Ft Collins, Colorado
7 shared publicationsBrandon G. Santoni
Orthopaedic Bioengineering Research Laboratory, Departments of Mechanical Engineering and School of Biomedical Engineering, Colorado State University, Fort Collins, Colorado, 80523
6 shared publicationsBenjamin C. Gadomski
Orthopaedic Bioengineering Research Laboratory, Department of Mechanical Engineering and School of Biomedical Engineering, Colorado State University, Ft Collins, Colorado
5 shared publicationsJeremiah T. Easley
Preclinical Surgical Research Laboratory, Department of Clinical Sciences, Colorado State University, Ft Collins, Colorado
5 shared publicationsKevin L. Troyer
Department of Mechanical Engineering, Colorado State University, Fort Collins, CO, USA
5 shared publicationsRoss H. Palmer
Preclinical Surgical Research Laboratory, Department of Clinical Sciences, Colorado State University, Ft Collins, Colorado
5 shared publications
Latest Publications
- 1 December 2019
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 100, 103395
Biaxial mechanics of 3D fiber deposited ply-laminate scaffolds for soft tissue engineering part II: Finite element analyses
- 1 December 2019
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 100, 103395
Biaxial mechanics of 3D fiber deposited ply-laminate scaffolds for soft tissue engineering part II: Finite element analyses
- 1 October 2019
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 98, 317-326
Biaxial mechanics of 3D fiber deposited ply-laminate scaffolds for soft tissue engineering part I: Experimental evaluation
- 1 October 2019
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 98, 317-326
Biaxial mechanics of 3D fiber deposited ply-laminate scaffolds for soft tissue engineering part I: Experimental evaluation
- 25 March 2019
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 141 (5)
Comparing Predictive Accuracy and Computational Costs for Viscoelastic Modeling of Spinal Cord Tissues
The constitutive equation used to characterize and model spinal tissues can significantly influence the conclusions from experimental and computational studies. Therefore, researchers must make critical judgments regarding the balance of computational efficiency and predictive accuracy necessary for their purposes. The objective of this study is to quantitatively compare the fitting and prediction accuracy of linear viscoelastic (LV), quasi-linear viscoelastic (QLV), and (fully) nonlinear viscoelastic (NLV) modeling of spinal-cord-pia-arachnoid-construct (SCPC), isolated cord parenchyma, and isolated pia-arachnoid-complex (PAC) mechanics in order to better inform these judgements. Experimental data collected during dynamic cyclic testing of each tissue condition were used to fit each viscoelastic formulation. These fitted models were then used to predict independent experimental data from stress-relaxation testing. Relative fitting accuracy was found not to directly reflect relative predictive accuracy, emphasizing the need for material model validation through predictions of independent data. For the SCPC and isolated cord, the NLV formulation best predicted the mechanical response to arbitrary loading conditions, but required significantly greater computational run time. The mechanical response of the PAC under arbitrary loading conditions was best predicted by the QLV formulation.
- 25 March 2019
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 141 (5)
Comparing Predictive Accuracy and Computational Costs for Viscoelastic Modeling of Spinal Cord Tissues
The constitutive equation used to characterize and model spinal tissues can significantly influence the conclusions from experimental and computational studies. Therefore, researchers must make critical judgments regarding the balance of computational efficiency and predictive accuracy necessary for their purposes. The objective of this study is to quantitatively compare the fitting and prediction accuracy of linear viscoelastic (LV), quasi-linear viscoelastic (QLV), and (fully) nonlinear viscoelastic (NLV) modeling of spinal-cord-pia-arachnoid-construct (SCPC), isolated cord parenchyma, and isolated pia-arachnoid-complex (PAC) mechanics in order to better inform these judgements. Experimental data collected during dynamic cyclic testing of each tissue condition were used to fit each viscoelastic formulation. These fitted models were then used to predict independent experimental data from stress-relaxation testing. Relative fitting accuracy was found not to directly reflect relative predictive accuracy, emphasizing the need for material model validation through predictions of independent data. For the SCPC and isolated cord, the NLV formulation best predicted the mechanical response to arbitrary loading conditions, but required significantly greater computational run time. The mechanical response of the PAC under arbitrary loading conditions was best predicted by the QLV formulation.
- 1 July 2018
- Published by Elsevier in Acta Biomaterialia
- Vol. 75, 253-262
Viscoelasticity of spinal cord and meningeal tissues
- 1 July 2018
- Published by Elsevier in Acta Biomaterialia
- Vol. 75, 253-262
Viscoelasticity of spinal cord and meningeal tissues
- 1 March 2018
- Published by Elsevier in Acta Biomaterialia
- Vol. 68, 78-89
Comparison of in vivo and ex vivo viscoelastic behavior of the spinal cord
- 1 March 2018
- Published by Elsevier in Acta Biomaterialia
- Vol. 68, 78-89
Comparison of in vivo and ex vivo viscoelastic behavior of the spinal cord
- Open Access
- 1 August 2017
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 36 (3) , 921-929
An investigation of shock wave therapy and low‐intensity pulsed ultrasound on fracture healing under reduced loading conditions in an ovine model
The use of shock wave therapy (SWT) and low‐intensity pulsed ultrasound (LIPUS) as countermeasures to the inhibited fracture healing experienced during mechanical unloading was investigated by administering treatment to the fracture sites of mature, female, Rambouillet Columbian ewes exposed to partial mechanical unloading or full gravitational loading. The amount of fracture healing experienced by the treatment groups was compared to controls in which identical surgical and testing protocols were administered except for SWT or LIPUS treatment. All groups were euthanized after a 28‐day healing period. In vivo mechanical measurements demonstrated no significant alteration in fixation plate strains between treatments within either partial unloading group. Similarly, DXA BMD and 4‐point bending stiffness were not significantly altered following either treatment. μCT analyses demonstrated lower callus bone volume for treated animals (SWT and LIPUS, p < 0.01) in the full gravity group but not between reduced loading groups. Callus osteoblast numbers as well as mineralized surface and bone formation rate were significantly elevated to the level of the full gravity groups in the reduced loading groups following both SWT and LIPUS. Although no increase in 4‐week mechanical strength was observed, it is possible that an increase in the overall rate of fracture healing (i.e., callus strength) may be experienced at longer time points under partial loading conditions given the increase in osteoblast numbers and bone formation parameters following SWT and LIPUS. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:921–929, 2018.
- 1 August 2017
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 36 (3) , 921-929
Open AccessAn investigation of shock wave therapy and low‐intensity pulsed ultrasound on fracture healing under reduced loading conditions in an ovine model
The use of shock wave therapy (SWT) and low‐intensity pulsed ultrasound (LIPUS) as countermeasures to the inhibited fracture healing experienced during mechanical unloading was investigated by administering treatment to the fracture sites of mature, female, Rambouillet Columbian ewes exposed to partial mechanical unloading or full gravitational loading. The amount of fracture healing experienced by the treatment groups was compared to controls in which identical surgical and testing protocols were administered except for SWT or LIPUS treatment. All groups were euthanized after a 28‐day healing period. In vivo mechanical measurements demonstrated no significant alteration in fixation plate strains between treatments within either partial unloading group. Similarly, DXA BMD and 4‐point bending stiffness were not significantly altered following either treatment. μCT analyses demonstrated lower callus bone volume for treated animals (SWT and LIPUS, p < 0.01) in the full gravity group but not between reduced loading groups. Callus osteoblast numbers as well as mineralized surface and bone formation rate were significantly elevated to the level of the full gravity groups in the reduced loading groups following both SWT and LIPUS. Although no increase in 4‐week mechanical strength was observed, it is possible that an increase in the overall rate of fracture healing (i.e., callus strength) may be experienced at longer time points under partial loading conditions given the increase in osteoblast numbers and bone formation parameters following SWT and LIPUS. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:921–929, 2018.
- 1 September 2016
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 62, 195-208
An anisotropic hyperelastic constitutive model of brain white matter in biaxial tension and structural–mechanical relationships
- 1 September 2016
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 62, 195-208
An anisotropic hyperelastic constitutive model of brain white matter in biaxial tension and structural–mechanical relationships
- 1 May 2016
- Published by Elsevier in Journal of Biomechanics
- Vol. 49 (7) , 1248-1254
Characterization of the L4–L5–S1 motion segment using the stepwise reduction method
- 1 May 2016
- Published by Elsevier in Journal of Biomechanics
- Vol. 49 (7) , 1248-1254
Characterization of the L4–L5–S1 motion segment using the stepwise reduction method
- 8 January 2016
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 34 (7) , 1206-1215
Computational characterization of fracture healing under reduced gravity loading conditions
The literature is deficient with regard to how the localized mechanical environment of skeletal tissue is altered during reduced gravitational loading and how these alterations affect fracture healing. Thus, a finite element model of the ovine hindlimb was created to characterize the local mechanical environment responsible for the inhibited fracture healing observed under experimental simulated hypogravity conditions. Following convergence and verification studies, hydrostatic pressure and strain within a diaphyseal fracture of the metatarsus were evaluated for models under both 1 and 0.25 g loading environments and compared to results of a related in vivo study. Results of the study suggest that reductions in hydrostatic pressure and strain of the healing fracture for animals exposed to reduced gravitational loading conditions contributed to an inhibited healing process, with animals exposed to the simulated hypogravity environment subsequently initiating an intramembranous bone formation process rather than the typical endochondral ossification healing process experienced by animals healing in a 1 g gravitational environment. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:1206-1215, 2016.
- 8 January 2016
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 34 (7) , 1206-1215
Computational characterization of fracture healing under reduced gravity loading conditions
The literature is deficient with regard to how the localized mechanical environment of skeletal tissue is altered during reduced gravitational loading and how these alterations affect fracture healing. Thus, a finite element model of the ovine hindlimb was created to characterize the local mechanical environment responsible for the inhibited fracture healing observed under experimental simulated hypogravity conditions. Following convergence and verification studies, hydrostatic pressure and strain within a diaphyseal fracture of the metatarsus were evaluated for models under both 1 and 0.25 g loading environments and compared to results of a related in vivo study. Results of the study suggest that reductions in hydrostatic pressure and strain of the healing fracture for animals exposed to reduced gravitational loading conditions contributed to an inhibited healing process, with animals exposed to the simulated hypogravity environment subsequently initiating an intramembranous bone formation process rather than the typical endochondral ossification healing process experienced by animals healing in a 1 g gravitational environment. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:1206-1215, 2016.