JMJose Maria Marin

Jose Maria Marin

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jose Maria Marin has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Optical correction in excised cataractous crystalline lenses by using wavefront shaping techniques

    by Pablo Artal, Irene Rodríguez-Fernández, Inés Yago, Jose María Marín, Alba M. Paniagua-Diaz

    Cataracts significantly degrade retinal image quality by scattering light within the crystalline lens. In this work, we apply wavefront shaping techniques to optimize the point spread function (PSF) formed through excised human lenses at advanced cataract stages, enabling improved image formation on the retinal plane. We employed both phase and binary amplitude modulation strategies with matched degrees of freedom for fair comparison. We analyze the isoplanatic patch size and demonstrate that concatenating multiple optimized PSFs can extend the effective imaging area. These results show the potential of wavefront shaping as a non-invasive, purely optical strategy for correcting cataract-induced image blur in the eye.


  • Open Access

    Clinical Results of a Monofocal Aspheric Bitoric Intraocular Lens with Plate Haptics in Hyperopic Eyes

    by Pedro Tañá-Rivero, José Muñoz-Tomás, Paz Orts-Vila, Enrique Artiaga-Elordi, Francisco Pastor-Pascual, José María Marín-Sánchez, Christian García-Elskamp

    To assess the refractive and visual outcomes of hyperopic and astigmatic eyes implanted with a monofocal, aspheric, bitoric intraocular lens (IOL) with plate haptics following cataract surgery. The study evaluated 51 eyes implanted with the AT TORBI 709M IOL (Carl Zeiss Meditec AG, Jena, Germany) during a follow-up of 12-months. Refractive error, rotational stability, monocular uncorrected distance visual acuity (UDVA), monocular corrected distance visual acuity (CDVA), and contrast sensitivity were analyzed at 1-, 6-, and 12-months post-surgery. At 12 months, the cumulative CDVA was 20/25 in 94.12% of eyes and 20/32 or better in 98.04%. The UDVA was the same as, or better than, the CDVA in 88.24% of eyes. The mean logMAR UDVA and CDVA values were 0.06 ± 0.11 and 0.00 ± 0.08, respectively. In addition, 92.16% of eyes were within ±0.50 D and 98.04% were within ±1.00 D of a spherical equivalent, and 86.27% of eyes had refractive astigmatism ≤0.50D and 100% were ≤1.00D. The mean spherical equivalent was 0.21 ± 0.31D and the mean refractive cylinder 0.34 ± 0.27D. The IOL rotation was 1.18 ± 1.35 degrees and all eyes had a rotation ≤5 degrees. The log contrast sensitivity functions were good and similar for all spatial frequencies during follow-up. Our results demonstrate that implantation of the AT TORBI 709M IOL in hyperopic and astigmatic eyes is effective and safe. The visual and refractive outcomes were good, showing excellent rotational stability.

  • Open Access

    Clinical Outcomes of a Monofocal, Optimized, Aspheric, Hydrophobic Acrylic Intraocular Lens Implant

    by Berta García-Tomás, José María Marín-Sánchez, Christian García-Elskamp, Encarnación Alcon-Ruiz, Laura Montesinos-López, Beatriz García Martínez-Lozano

    Purpose: To evaluate the refractive and visual outcomes of eyes implanted with monofocal, optimized, aspheric, hydrophobic acrylic intraocular lenses (IOL) following cataract surgery. Methods: The study assessed 55 eyes implanted with CT LUCIA® 621P IOLs (Carl Zeiss Meditec AG, Jena, Germany) at 3-months postsurgery. The main outcome measures were refractive error, monocular corrected distance visual acuity (CDVA), monocular uncorrected distance visual acuity (UDVA), photopic and mesopic contrast sensitivity, and wavefront aberrations. Patients were asked to complete the Catquest-9SF questionnaire. Results: At 3 months, the cumulative Snellen visual acuity was 20/20 in 94.55% of eyes and 20/25 or better in 100%. The difference between the UDVA and CDVA was either the same (70.91%) or better (29.09%) in all eyes. The mean Snellen decimal UDVA and DCVA were 1.07 ± 0.15 and 1.13 ± 0.11, respectively. The safety and efficacy indexes were 1.48 and 1.40, respectively. 47.27% of eyes showed a spherical equivalent ± 0.13 D, with 92.73% of the eyes were within ± 0.50 D and all eyes were within ± 1.00 D. The mean spherical equivalent was − 0.03 ± 0.30 D and the mean refractive cylinder − 0.36 ± 0.34 D. The log photopic and mesopic contrast sensitivity functions were good and similar for all spatial frequencies. All patients reported being either fairly satisfied (score 3) or very satisfied (score 4) with their vision (mean = 3.64 ± 0.49). No intra- and postoperative complications were reported during the 3 months of follow-up. Conclusion: The current study demonstrates that excellent visual and refractive outcomes, as well as patient satisfaction, can be achieved after cataract surgery with optimized, aspheric CT LUCIA 621P monofocal IOLs.


  • Optical Measurement of Straylight in Eyes With Cataract

    by Onurcan Sahin, Alexandros Pennos, Harilaos Ginis, Lucia Hervella, Eloy A. Villegas, Belen Cañizares, Jose Maria Marin, Ioannis Pallikaris, Pablo Artal

    PURPOSE: To measure straylight in a cohort of patients with cataract using a novel optical instrument and to correlate optical straylight values with clinical grade of cataracts and psychophysical straylight values. METHODS: Measurements were performed on 53 eyes of 44 patients with cataract admitted to the ophthalmology service of the university hospital in Murcia, Spain, and 9 young volunteers with no known ophthalmic pathology. Lens opacities were classified according to the Lens Opacities Classification System Ill (LOCS III) under slit-lamp examination. Intraocular straylight was additionally assessed psychophysically using the C-Quant straylight meter (Oculus Optikgeräte GmbH, Wetzlar, Germany). RESULTS: Optical measurements of the logarithm of the straylight parameter ranged from 1.01 to 2.01 (mean: 1.43 ± 0.244) in patients with cataract and 0.80 to 1.08 (mean: 0.92 ± 0.104) in healthy young volunteers. Straylight differed by a statistically significant amount among different LOCS III groups ( P < .05). Moreover, the optically measured straylight parameter was positively correlated to the psychophysically estimated value ( r = 0.803, P < .05). CONCLUSIONS: A new compact optical instrument suitable for clinical measurements of straylight in the human eye has been developed. Optically measured straylight values were highly correlated to those that were obtained psychophysically. Optical measurement of straylight can be used for the objective classification of cataract opacities based on their optical impact. [ J Refract Surg . 2016;32(12):846–850.]


  • Macular Retinal Ganglion Cell Layer Thickness Is Not Reduced in Patients with Obstructive Sleep Apnea

    by Blanca Ferrandez, Antonio Ferreras, Pilar Calvo, Beatriz Abadia, Ana B. Pajarin, Jose M. Marin, Michele Iester

    Purpose: To evaluate macular ganglion cell layer (GCL) and ganglion cell-inner plexiform layer (GCIPL) thicknesses in patients with obstructive sleep apnea (OSA) syndrome. Methods: 73 OSA patients and 67 age-matched controls were consecutively and prospectively enrolled. All participants underwent at least one reliable standard automated perimetry (SAP) and were imaged with spectral-domain optical coherence tomography (OCT) using two different devices. The OCT parameters were compared between groups, and Pearson correlations between main indices of SAP and OCT parameters were calculated. Results: The pattern standard deviation of SAP was higher in the OSA group (p = 0.001). Mean GCIPL thickness was 82.99 ± 10.30 and 80.78 ± 12.15 µm in the control and OSA groups, respectively (p = 0.25), and GCL thickness was 44.93 ± 11.42 µm in the control group and 48.81 ± 10.85 µm in OSA individuals (p = 0.47). Pearson correlations between the GCIPL-GCL measurements and the main indices of SAP were not significant. Conclusions: Neither GCIPL nor GCL thickness were reduced in OSA subjects compared with healthy individuals. Retinal sensitivity evaluated with SAP was however decreased in OSA patients.


  • Open Access

    Assessment of the retinal nerve fiber layer in individuals with obstructive sleep apnea

    by Blanca Ferrandez, Antonio Ferreras, Pilar Calvo, Beatriz Abadia, Jose M. Marin, Ana B. Pajarin

    The effect of obstructive sleep apnea (OSA) syndrome in the peripapillary retinal nerve fiber layer (RNFL) thicknesses remains unclear. The purpose of this study was to assess RNFL measurements acquired using scanning laser polarimetry (SLP) and optical coherence tomography (OCT) in patients with OSA. The sample of this cross-sectional study included 40 OSA patients and 45 age-matched controls, consecutively and prospectively selected. All participants underwent at least one reliable standard automated perimetry (SAP) test, while RNFL measurements were obtained using the SLP and OCT. The OSA group was divided into 3 sub-groups based on the apnea/hypopnea index (AHI): mild, moderate, or severe OSA. SAP, SLP, and OCT outcomes were compared between the control and OSA groups. The relationship between AHI and RNFL parameters was also evaluated. Age was not different between both groups. Mean deviation of SAP was −0.47 ± 0.9 dB and −1.43 ± 2.3 dB in the control and OSA groups, respectively (p = 0.01). RNFL thickness measured with OCT was similar between groups. OSA patients showed increased nerve fiber indicator (NFI; 20.9 ± 7.9 versus 16.42 ± 7.82; p = 0.01) and decreased superior average (59.74 ± 10.35 versus 63.73 ± 6.58; p = 0.03) obtained with SLP compared with healthy individuals. In the total sample, NFI and AHI were moderately correlated (r = 0.358; p = 0.001). In severe OSA subjects (n = 22), NFI and AHI had a Spearman correlation coefficient of 0.44 (p = 0.04). RNFL thickness measured with OCT did not differ significantly between groups. Severe OSA was related to a reduction of the RNFL thickness assessed by SLP.


  • Retinal Sensitivity Is Reduced in Patients With Obstructive Sleep Apnea

    by Blanca Ferrandez, Antonio Ferreras, Pilar Calvo, Beatriz Abadia, Paolo Fogagnolo, Yaowu Wang, Jose M. Marin, Michele Iester

    Purpose. To evaluate the outcomes of standard automated perimetry (SAP) in patients with obstructive sleep apnea (OSA). Methods. Eighty OSA patients and 111 age-matched controls were consecutively and prospectively enrolled. One eye per subject was randomly selected. All participants underwent at least one reliable SAP (24-2 SITA Standard algorithm). The peripapillary retinal nerve fiber layer thickness (RNFL) was measured with spectral-domain optical coherence tomography (OCT). Patients with OSA were classified into three groups according to the apnea/hypopnea index: mild, moderate, or severe OSA. Parameters of SAP and OCT were compared between healthy controls and OSA patients. Correlation of apnea/hypopnea index with OCT and SAP measurements were calculated. Results. Mean age, best-corrected visual acuity, and central corneal thickness were similar between groups. Intraocular pressure, however, was lower in the OSA group. Mean deviation of SAP was −0.23 ± 0.8 dB in the control group and −1.74 ± 2.8 dB in the OSA group (P < 0.001). Thickness of RNFL measured with OCT did not differ significantly between groups. Patients with OSA showed reduced sensitivity at most points tested by white-on-white perimetry compared with healthy individuals. The threshold values were more depressed in the peripheral visual field. The apnea/hypopnea index was related to the SAP indices: Pearson correlations were −0.432 with mean deviation, 0.467 with pattern standard deviation, and −0.416 with the visual field index (P < 0.001). Conclusions. Patients with OSA exhibited reduced retinal sensitivity measured with SAP compared with healthy controls.