V. Gopalakrishnan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
V. Gopalakrishnan has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
K. Devan
3 shared publicationsP. Mohanakrishnan
3 shared publicationsB. Malarvizhi
Indira Gandhi Centre for Atomic Research, Kalpakkam, TN, India
2 shared publicationsG. Pandikumar
2 shared publicationsN. Kasinathan
Indira Gandhi Centre for Atomic Research, Kalpakkam, TN, India
2 shared publicationsA. Jasmin Sudha
Indira Gandhi Centre for Atomic Research, Kalpakkam, TN, India
1 shared publication
Latest Publications
- 1 July 2008
- Published by Elsevier in Energy Conversion and Management
- Vol. 49 (7) , 1810-1819
Report on intermediate results of the IAEA CRP on ‘Studies of advanced reactor technology options for effective incineration of radioactive waste’
- 1 July 2008
- Published by Elsevier in Energy Conversion and Management
- Vol. 49 (7) , 1810-1819
Report on intermediate results of the IAEA CRP on ‘Studies of advanced reactor technology options for effective incineration of radioactive waste’
- 1 January 2006
- Published by ASME International
- p. 197-203
Numerical and Experimental Model Studies on Thermal Hydraulic Behavior of FBR Internal Core Catcher Assembly
Core Catcher is provided as an in-vessel core debris retention device to collect, support, cool and maintain in sub-critical configuration, the generated core debris from fuel melting due to certain postulated Beyond Design Basis Events (BDBE) for Fast Breeder Reactor (FBR). This also acts as a barrier to prevent settling of debris on main vessel and keeps its maximum temperature within acceptable creep range. Heat transfer by natural convection in the core catcher assembly has been assessed numerically and through water experiments using geometrically similar configuration. Resistive heating elements are used in experiment as heat source to simulate debris decay heat on core catcher. Series of experiments were carried out for two configurations referred as geometry A and geometry B. The later configuration showed enhanced natural convective heat transfer from the lower plenum of the vessel. Temperatures were monitored at critical positions and compared with numerical evaluation. Numerically evaluated flow fields and isotherms are compared with experimental data for specific steady state temperatures on heat source plate. Numerical results are found to be in good agreement with that obtained from experiments. The combined efforts of numerical and experimental work conclude core catcher assembly with geometry B to be more suitable.
- 1 January 2006
- Published by ASME International
- p. 197-203
Numerical and Experimental Model Studies on Thermal Hydraulic Behavior of FBR Internal Core Catcher Assembly
Core Catcher is provided as an in-vessel core debris retention device to collect, support, cool and maintain in sub-critical configuration, the generated core debris from fuel melting due to certain postulated Beyond Design Basis Events (BDBE) for Fast Breeder Reactor (FBR). This also acts as a barrier to prevent settling of debris on main vessel and keeps its maximum temperature within acceptable creep range. Heat transfer by natural convection in the core catcher assembly has been assessed numerically and through water experiments using geometrically similar configuration. Resistive heating elements are used in experiment as heat source to simulate debris decay heat on core catcher. Series of experiments were carried out for two configurations referred as geometry A and geometry B. The later configuration showed enhanced natural convective heat transfer from the lower plenum of the vessel. Temperatures were monitored at critical positions and compared with numerical evaluation. Numerically evaluated flow fields and isotherms are compared with experimental data for specific steady state temperatures on heat source plate. Numerical results are found to be in good agreement with that obtained from experiments. The combined efforts of numerical and experimental work conclude core catcher assembly with geometry B to be more suitable.
- 1 January 2006
- Published by ASME International
- p. 301-307
Experimental Evaluation of Pool Fire Suppression Performance of Sodium Leak Collection Tray in Open Air
In the event of sodium leakage from heat transfer circuits of fast breeder reactors (FBR), liquid sodium catches fire in ambient air leading to production of flame, smoke and heat. One of the passive fire protection methods involves immediate collection of the leaking sodium to a sodium hold-up vessel (SHV) covered with a sloping cover tray (SCT) having a few drain pipes and one vent pipe (as in Fig. 1). As soon as the liquid sodium falls on the sloping cover tray, gravity guides the sodium through drain pipes into the bottom tray in which self-extinction occurs due to oxygen starvation. This sodium fire protection equipment called leak collection tray (LCT) works without the intervention of an operator and external power source. A large number of LCTs are strategically arranged under the sodium circulating pipe lines in the FBR plants to serve as passive suppression devices. In order to test the efficacy of the LCT, four tests were conducted. Two tests were with LCT having three drain pipes and rest with one. In each experiment, nearly 40 kg of hot liquid sodium at 550 °C was discharged on the LCT in the open air. Continuous on-line monitoring of temperature at strategic locations (∼ 28 points) were carried out. Colour videography was employed for taking motion pictures of various time-dependent events like sodium dumping, appearance of flame and release of smoke through vent pipes. After self-extinction of sodium fire, the LCT was allowed to cool overnight in an argon atmosphere. Solid samples of sodium debris in the SCT and SHV were collected by manual core drilling machine. The samples were subjected to chemical analysis for determination of unburnt and burnt sodium. The results of the four tests revealed an interesting feature: LCT with three drain pipes showed far lower sodium collection efficiency and much higher sodium combustion than that with just one drain pipe. Thermal fluctuations in temperature sensor located near the tip of the drain pipe have indicated that transient freezing and remelting processes are responsible for this phenomenon. Moreover comparison of test results between present and earlier experiments has revealed that the LCT with funnel shaped SCT is superior to that with boat shaped SCT.
- 1 January 2006
- Published by ASME International
- p. 301-307
Experimental Evaluation of Pool Fire Suppression Performance of Sodium Leak Collection Tray in Open Air
In the event of sodium leakage from heat transfer circuits of fast breeder reactors (FBR), liquid sodium catches fire in ambient air leading to production of flame, smoke and heat. One of the passive fire protection methods involves immediate collection of the leaking sodium to a sodium hold-up vessel (SHV) covered with a sloping cover tray (SCT) having a few drain pipes and one vent pipe (as in Fig. 1). As soon as the liquid sodium falls on the sloping cover tray, gravity guides the sodium through drain pipes into the bottom tray in which self-extinction occurs due to oxygen starvation. This sodium fire protection equipment called leak collection tray (LCT) works without the intervention of an operator and external power source. A large number of LCTs are strategically arranged under the sodium circulating pipe lines in the FBR plants to serve as passive suppression devices. In order to test the efficacy of the LCT, four tests were conducted. Two tests were with LCT having three drain pipes and rest with one. In each experiment, nearly 40 kg of hot liquid sodium at 550 °C was discharged on the LCT in the open air. Continuous on-line monitoring of temperature at strategic locations (∼ 28 points) were carried out. Colour videography was employed for taking motion pictures of various time-dependent events like sodium dumping, appearance of flame and release of smoke through vent pipes. After self-extinction of sodium fire, the LCT was allowed to cool overnight in an argon atmosphere. Solid samples of sodium debris in the SCT and SHV were collected by manual core drilling machine. The samples were subjected to chemical analysis for determination of unburnt and burnt sodium. The results of the four tests revealed an interesting feature: LCT with three drain pipes showed far lower sodium collection efficiency and much higher sodium combustion than that with just one drain pipe. Thermal fluctuations in temperature sensor located near the tip of the drain pipe have indicated that transient freezing and remelting processes are responsible for this phenomenon. Moreover comparison of test results between present and earlier experiments has revealed that the LCT with funnel shaped SCT is superior to that with boat shaped SCT.
- 1 July 2003
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 30 (11) , 1181-1197
Effects of cross section sets and quadrature orders on neutron fluxes and on secondary 24Na activation rate of a pool type 500 MWe FBR
- 1 July 2003
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 30 (11) , 1181-1197
Effects of cross section sets and quadrature orders on neutron fluxes and on secondary 24Na activation rate of a pool type 500 MWe FBR
- 1 July 1996
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 23 (10) , 791-800
Generation and validation of a new 121 group coupled (n, γ) cross section library for fast reactor applications
- 1 July 1996
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 23 (10) , 791-800
Generation and validation of a new 121 group coupled (n, γ) cross section library for fast reactor applications
- 1 January 1988
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 15 (3) , 113-140
Verification of the accuracy of Doppler broadened, self-shielded multigroup cross sections for fast power reactor applications
- 1 January 1988
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 15 (3) , 113-140
Verification of the accuracy of Doppler broadened, self-shielded multigroup cross sections for fast power reactor applications