J. Brian Anderson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
J. Brian Anderson has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
F. C. Townsend
Assistant Professor, Dept. of Civil Engineering, Univ. of North Carolina at Charlotte, Charlotte, NC 28223-0001
1 shared publicationL. Rahelison
Assistant Professor, Dept. of Civil Engineering, Univ. of North Carolina at Charlotte, Charlotte, NC 28223-0001
1 shared publication- M. Allen Cottingham
Associate Professor, University of North Carolina Charlotte, Department of Civil and Environmental Engineering, 9201 University City Blvd., Charlotte, NC USA
1 shared publication - Paul J. Cosentino
Civil Engineering Department, Engineering College, Florida Institute of Technology, Melbourne, USA
1 shared publication - Richard E. Burrage
Graduate student, University of North Carolina at Charlotte, Department of Civil and Environmental Engineering, 9201 University City Boulevard, Charlotte, NC USA
1 shared publication - Vincent O. Ogunro
Univ. of North Carolina at Charlotte
1 shared publication
Latest Publications
- 10 March 2009
- Published by American Society of Civil Engineers (ASCE)
- p. 81-88
Instrumented Sheet Pile Wall Load Test to Indirectly Measure Earth Pressure
Two parallel retaining walls were constructed from 10.4 m embedded PZ22 sheet piles in order to indirectly measure the amount of earth pressure induced during excavation. Selected sheets were instrumented in an effort to measure bending moment and deflection, whereby the induced earth pressure could be discerned. Four sheets were instrumented, each with 16 strain gages (eight gages per flange) to detect bending moment. Steel tubing was attached to four additional piles for use with an inclinometer to measure horizontal movement. The soil between the walls was excavated in five equal lifts over a ten day period until the total depth of excavation was 6.1 meters. Strain gages were continuously monitored while inclinometer readings were taken at the completion of each excavation lift. The qualitative and quantitative results of the load tests showed no mobilization of lateral earth pressure on the walls with an excavation depth of 6.1 meters.
- 10 March 2009
- Published by American Society of Civil Engineers (ASCE)
- p. 81-88
Instrumented Sheet Pile Wall Load Test to Indirectly Measure Earth Pressure
Two parallel retaining walls were constructed from 10.4 m embedded PZ22 sheet piles in order to indirectly measure the amount of earth pressure induced during excavation. Selected sheets were instrumented in an effort to measure bending moment and deflection, whereby the induced earth pressure could be discerned. Four sheets were instrumented, each with 16 strain gages (eight gages per flange) to detect bending moment. Steel tubing was attached to four additional piles for use with an inclinometer to measure horizontal movement. The soil between the walls was excavated in five equal lifts over a ten day period until the total depth of excavation was 6.1 meters. Strain gages were continuously monitored while inclinometer readings were taken at the completion of each excavation lift. The qualitative and quantitative results of the load tests showed no mobilization of lateral earth pressure on the walls with an excavation depth of 6.1 meters.
- 10 March 2009
- Published by American Society of Civil Engineers (ASCE)
- p. 34-41
PENCEL Pressuremeter Testing for the Development of p-y Curves for Deep Foundations: Examination and Comparison of Case Histories
This paper presents the results of twelve lateral load test prediction case histories that include a mixture of both piles and drilled shafts in single or group configurations. PENCEL pressuremeter tests at the load test sites were used to develop p-y curves for analysis. The load tests were simulated using the program FB-MultiPier with the PENCEL pressuremeter based p-y curves. The quality of predictions suggests that p-y curves developed from PENCEL pressuremeter tests are viable. According to these cases, there is no difference in prediction between cohesionless and cohesive soil. The response of drilled shafts was predicted better than that of piles. The response of concrete foundations overall was modeled more accurately than that of steel foundations.
- 10 March 2009
- Published by American Society of Civil Engineers (ASCE)
- p. 34-41
PENCEL Pressuremeter Testing for the Development of p-y Curves for Deep Foundations: Examination and Comparison of Case Histories
This paper presents the results of twelve lateral load test prediction case histories that include a mixture of both piles and drilled shafts in single or group configurations. PENCEL pressuremeter tests at the load test sites were used to develop p-y curves for analysis. The load tests were simulated using the program FB-MultiPier with the PENCEL pressuremeter based p-y curves. The quality of predictions suggests that p-y curves developed from PENCEL pressuremeter tests are viable. According to these cases, there is no difference in prediction between cohesionless and cohesive soil. The response of drilled shafts was predicted better than that of piles. The response of concrete foundations overall was modeled more accurately than that of steel foundations.
- 1 December 2007
- Published by American Society of Civil Engineers (ASCE) in Journal of Geotechnical and Geoenvironmental Engineering
- Vol. 133 (12) , 1494-1502
Load Testing and Settlement Prediction of Shallow Foundation
The purpose of this study was to critically examine insitu test methods as a means for predicting settlement of shallow foundations. Accordingly, a 1.8 m (6 ft) diameter concrete footing was statically load tested. Prior to construction, insitu [standard penetration test (SPT), cone penetration test (CPT), dilatometer (DMT), and pressuremeter (PMT)] and laboratory tests were performed to determine engineering properties of the soil. Predictions of the footing settlement were made by traditional as well as finite element methods. The results of the static load test showed settlements were over predicted by all methods. However, the traditional methods provided reasonable settlement estimates using either SPT- N or back computed CPT(N) as input. Finite element analyses using either DMT or CPT derived input parameters provided reasonable settlement estimates. Finite element analyses using SPT or PMT derived input parameters provided poor settlement estimates. The Mohr–Coulomb (elastoplastic) model, accountin...
- 1 December 2007
- Published by American Society of Civil Engineers (ASCE) in Journal of Geotechnical and Geoenvironmental Engineering
- Vol. 133 (12) , 1494-1502
Load Testing and Settlement Prediction of Shallow Foundation
The purpose of this study was to critically examine insitu test methods as a means for predicting settlement of shallow foundations. Accordingly, a 1.8 m (6 ft) diameter concrete footing was statically load tested. Prior to construction, insitu [standard penetration test (SPT), cone penetration test (CPT), dilatometer (DMT), and pressuremeter (PMT)] and laboratory tests were performed to determine engineering properties of the soil. Predictions of the footing settlement were made by traditional as well as finite element methods. The results of the static load test showed settlements were over predicted by all methods. However, the traditional methods provided reasonable settlement estimates using either SPT- N or back computed CPT(N) as input. Finite element analyses using either DMT or CPT derived input parameters provided reasonable settlement estimates. Finite element analyses using SPT or PMT derived input parameters provided poor settlement estimates. The Mohr–Coulomb (elastoplastic) model, accountin...