Renata Pereira de Sousa Barbosa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Renata Pereira de Sousa Barbosa has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- André Luis Faria-E-Silva
Department of Dentistry, Dental School, Laval University, Québec QC, Canada
1 shared publication Carina Maria Lyra
Post-Graduate Program in Dentistry, ABO - Brazilian Dental Association, Florianópolis, SC, Brazil
1 shared publicationCarla Cristina Camilo
Department of Dentistry, UNIMONTES - State University of Montes Claros, Montes Claros, MG, Brazil
1 shared publication- Cristiane Duque
Faculty of Dental Medicine, Centre for Interdisciplinary Research in Health (CIIS), Universidade Católica Portuguesa, Viseu, Portugal
1 shared publication César Augusto Pereira Oliveira
Post-Graduate Program in Dentistry, ABO - Brazilian Dental Association, Florianópolis, SC, Brazil
1 shared publicationDébora Delai
Post-Graduate Program in Dentistry, Dental School, UFRGS - Universidade Federal do Rio Grande do Sul, Porto Alegre, RS, Brazil
1 shared publication
Latest Publications
- Open Access
- 1 December 2016
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 27 (6) , 681-687
Streptococcus Mutans Biofilm Influences on the Antimicrobial Properties of Glass Ionomer Cements
The aim of this study was to evaluate the in vitro antibacterial and biofilm inhibition properties of glass ionomer restorative cements. Ketac Nano, Vitremer, Ketac Molar Easymix and Fuji IX were analyzed using the following tests: a) agar plate diffusion test to evaluate the inhibitory activity of cements against S. mutans (n=8); b) S. mutans adherence test by counting colony-forming units after 2 h of material/bacteria exposure (n=10); c) biofilm wet weight after seven days of bacterial accumulation on material disks, with growth medium renewed every 48 h (n=10); d) pH and fluoride measurements from the medium aspired at 48 h intervals during the 7-day biofilm development (n=10). Data from the a, b and c tests were submitted to Kruskal-Wallis and Mann-Whitney tests and the fluoride-release and pH data were submitted to two-way ANOVA and Tukey tests (a=5%). Vitremer followed by Ketac Nano showed the greatest inhibitory zone against S. mutans than the conventional ionomers. Vitremer also showed higher pH values than Ketac Nano and Fuji IX in the first 48 h and released higher fluoride amount than Ketac Nano e Ketac Molar Easymix throughout the experimental period. The chemical composition of restorative glass ionomer materials influenced the antibacterial properties. The resin modified glass ionomer (Vitremer) was more effective for inhibition of S. mutans and allowed greater neutralization of the pH in the first 48 h. However, the type of glass ionomer (resin modified or conventional) did not influence the weight and adherence of the biofilm and fluoride release.
- 1 December 2016
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 27 (6) , 681-687
Open AccessStreptococcus Mutans Biofilm Influences on the Antimicrobial Properties of Glass Ionomer Cements
The aim of this study was to evaluate the in vitro antibacterial and biofilm inhibition properties of glass ionomer restorative cements. Ketac Nano, Vitremer, Ketac Molar Easymix and Fuji IX were analyzed using the following tests: a) agar plate diffusion test to evaluate the inhibitory activity of cements against S. mutans (n=8); b) S. mutans adherence test by counting colony-forming units after 2 h of material/bacteria exposure (n=10); c) biofilm wet weight after seven days of bacterial accumulation on material disks, with growth medium renewed every 48 h (n=10); d) pH and fluoride measurements from the medium aspired at 48 h intervals during the 7-day biofilm development (n=10). Data from the a, b and c tests were submitted to Kruskal-Wallis and Mann-Whitney tests and the fluoride-release and pH data were submitted to two-way ANOVA and Tukey tests (a=5%). Vitremer followed by Ketac Nano showed the greatest inhibitory zone against S. mutans than the conventional ionomers. Vitremer also showed higher pH values than Ketac Nano and Fuji IX in the first 48 h and released higher fluoride amount than Ketac Nano e Ketac Molar Easymix throughout the experimental period. The chemical composition of restorative glass ionomer materials influenced the antibacterial properties. The resin modified glass ionomer (Vitremer) was more effective for inhibition of S. mutans and allowed greater neutralization of the pH in the first 48 h. However, the type of glass ionomer (resin modified or conventional) did not influence the weight and adherence of the biofilm and fluoride release.
- Open Access
- 1 October 2015
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 26 (5) , 525-529
Morphology of Mesiobuccal Root Canals of Maxillary First Molars: a comparison of CBCT scanning and Cross-sectioning
The aim of this study was to evaluate the mesiobuccal root of maxillary first molars, according to the root canal configuration, prevalence and location of isthmuses at 3 and 6 mm from the apex, comparing cone-beam computed tomography (CBCT) analysis and cross sectioning of roots by thirds. Images of the mesiobuccal root of 100 maxillary first molars were acquired by CBCT and then roots were cross-sectioned into two parts, starting at 3 mm from the apex. Data were recorded and analyzed according to Weine's classification for root canal configuration, and Hsu and Kim's classification for isthmuses. In the analysis of CBCT images, 8 root canals were classified as type I, 57 as type II, 35 as type III. In the cross-sectioning technique, 19 root canals were classified as type I, 60 as type II, 20 as type III and 1 as type IV. The classification of isthmuses was predominantly type I in both CBCT and cross-sectioning evaluations for sections at 3 mm from the apex, while for sections at 6 mm from the apex, the classification of isthmuses was predominantly types V and II in CBCT and cross-sectioning evaluations, respectively. The cross-sectioning technique showed better results in detection of the internal morphology of root canals than CBCT scanning.
- 1 October 2015
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 26 (5) , 525-529
Open AccessMorphology of Mesiobuccal Root Canals of Maxillary First Molars: a comparison of CBCT scanning and Cross-sectioning
The aim of this study was to evaluate the mesiobuccal root of maxillary first molars, according to the root canal configuration, prevalence and location of isthmuses at 3 and 6 mm from the apex, comparing cone-beam computed tomography (CBCT) analysis and cross sectioning of roots by thirds. Images of the mesiobuccal root of 100 maxillary first molars were acquired by CBCT and then roots were cross-sectioned into two parts, starting at 3 mm from the apex. Data were recorded and analyzed according to Weine's classification for root canal configuration, and Hsu and Kim's classification for isthmuses. In the analysis of CBCT images, 8 root canals were classified as type I, 57 as type II, 35 as type III. In the cross-sectioning technique, 19 root canals were classified as type I, 60 as type II, 20 as type III and 1 as type IV. The classification of isthmuses was predominantly type I in both CBCT and cross-sectioning evaluations for sections at 3 mm from the apex, while for sections at 6 mm from the apex, the classification of isthmuses was predominantly types V and II in CBCT and cross-sectioning evaluations, respectively. The cross-sectioning technique showed better results in detection of the internal morphology of root canals than CBCT scanning.
- Open Access
- 1 February 2015
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 26 (1) , 79-85
Alternative Techniques to Remove Fractured Instrument Fragments from the Apical Third of Root Canals: Report of Two Cases
This paper describes two cases of instrument fragment removal from the apical thirds of root canals using a customized extractor and a modified needle technique, respectively. In case 1, a customized extractor was manufactured to remove a bur fragment located in the apical root canal of a maxillary central incisor. The use of this extractor enabled successful and conservative removal of the instrument fragment. In case 2, a modified injection needle was used as a trepan to gain access around an instrument fragment located in the curved apical portion of the mesiobuccal canal of a mandibular molar. A segment of steel wire was inserted into the needle lumen to engage the metallic fragment, enabling its removal with counter-clockwise rotation and a simultaneous pull-out motion. Alternative and creative methods are useful for the management of intracanal metallic fragments during root canal treatment.
- 1 February 2015
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 26 (1) , 79-85
Open AccessAlternative Techniques to Remove Fractured Instrument Fragments from the Apical Third of Root Canals: Report of Two Cases
This paper describes two cases of instrument fragment removal from the apical thirds of root canals using a customized extractor and a modified needle technique, respectively. In case 1, a customized extractor was manufactured to remove a bur fragment located in the apical root canal of a maxillary central incisor. The use of this extractor enabled successful and conservative removal of the instrument fragment. In case 2, a modified injection needle was used as a trepan to gain access around an instrument fragment located in the curved apical portion of the mesiobuccal canal of a mandibular molar. A segment of steel wire was inserted into the needle lumen to engage the metallic fragment, enabling its removal with counter-clockwise rotation and a simultaneous pull-out motion. Alternative and creative methods are useful for the management of intracanal metallic fragments during root canal treatment.
- Open Access
- 1 January 2011
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 22 (5) , 365-368
Effect of surface sealant on the color stability of composite resin restorations
This study investigated the effect of sealant application on the color stability of composite resin restorations. Cavities in bovine incisors were restored with composite resin (Opallis; FGM) and the teeth were assigned to 4 groups (n=10). A sealant (Fill Glaze; Vigodent) was applied over the restorations of 2 groups. Baseline color measurements based on the CIEL*a*b* system were carried out using a spectrophotometer. Half the number of specimens was immersed in distilled water, and half was immersed in coffee 4 h/day. Color measurements were repeated after 1 h, 24 h, 7 days and 3 months. Data for each immersion solution were separately subjected to a two-way repeated measures ANOVA and Tukey’s test (α=0.05). For the group without sealant immersed in water, no significant differences were observed among the periods (p≥0.138), but the color was different compared with baseline (p<0.001). For the group with sealant application, the periods baseline, 1 h and 3 months presented similar results (p≥0.924). For groups immersed in coffee, when the sealant was not used, no significant differences were detected between the baseline and the periods 1 h and 24 h (p≥0.499), but the color changed significantly thereafter (p≤0.003). In the group with sealant, significant differences were detected for all periods compared with each other (p<0.001). In conclusion, application of sealant dramatically increased the staining of the restorations exposed to coffee.
- 1 January 2011
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 22 (5) , 365-368
Open AccessEffect of surface sealant on the color stability of composite resin restorations
This study investigated the effect of sealant application on the color stability of composite resin restorations. Cavities in bovine incisors were restored with composite resin (Opallis; FGM) and the teeth were assigned to 4 groups (n=10). A sealant (Fill Glaze; Vigodent) was applied over the restorations of 2 groups. Baseline color measurements based on the CIEL*a*b* system were carried out using a spectrophotometer. Half the number of specimens was immersed in distilled water, and half was immersed in coffee 4 h/day. Color measurements were repeated after 1 h, 24 h, 7 days and 3 months. Data for each immersion solution were separately subjected to a two-way repeated measures ANOVA and Tukey’s test (α=0.05). For the group without sealant immersed in water, no significant differences were observed among the periods (p≥0.138), but the color was different compared with baseline (p<0.001). For the group with sealant application, the periods baseline, 1 h and 3 months presented similar results (p≥0.924). For groups immersed in coffee, when the sealant was not used, no significant differences were detected between the baseline and the periods 1 h and 24 h (p≥0.499), but the color changed significantly thereafter (p≤0.003). In the group with sealant, significant differences were detected for all periods compared with each other (p<0.001). In conclusion, application of sealant dramatically increased the staining of the restorations exposed to coffee.