Meera Mohaideen Hj Abd Kareem
Meera Mohaideen Hj Abd Kareem has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Arefuddin Ahmed
Medical Radiation Program, School of Health Sciences, Universiti Sains Malaysia, Kubang Kerian, 16150, Kelantan, Malaysia
1 shared publication- Badlishah Ahmad
Universiti Malaysia Perlis
1 shared publication - Kumarasamy Thangaraj
CSIR-Centre for Cellular and Molecular Biology, Hyderabad, India
1 shared publication - M. Zikri Ahmad
Department of Emergency Medicine and Radiology, School of Medical Sciences, Health Campus, Universiti Sains Malaysia, 16150, Kota Bharu, Kelantan, Malaysia
1 shared publication - Mohamad Iqhbal Bin Kunji Mohamad
Department of Emergency Medicine, Faculty of Medicine, Selangor Branch, Universiti Teknologi MARA, Jalan Hospital, Sungai Buloh, Malaysia
1 shared publication Mohamad Iqhbal Kunji
Department of Emergency Medicine and Radiology, School of Medical Sciences, Health Campus, Universiti Sains Malaysia, 16150, Kota Bharu, Kelantan, Malaysia
1 shared publication
Latest Publications
- Open Access
- 19 February 2016
- Published by Springer Nature in International Journal of Emergency Medicine
- Vol. 9 (1) , 1-6
Ultrasonographic assessment of inferior vena cava/abdominal aorta diameter index: a new approach of assessing hypovolemic shock class 1
We designed this study to expand the usage of ultrasound to detect early occurrence of hypovolemia. We explore the potential use of inferior vena cava (IVC) and abdominal aorta (AA) diameter index (IVC:AA) measured ultrasonographically to detect class 1 hypovolemic shock with blood loss less than 15%.ᅟ The aim of this study was to determine the changes in the diameter of inferior vena cava and abdominal aorta in blood donors by using ultrasound, pre and post blood donation. The result of the study would be further explorated to determine the inferior vena cava (IVC) abdominal aorta (Aorta) diameter index (IVC:Aorta). This was a prospective study done in the blood bank of a university hospital. Researcher was trained by a senior radiologist to assess inferior vena cava and abdominal aorta diameter. Fifty-two healthy blood donors were included in the study. Inclusion criteria were same with the blood bank criteria to donate blood. Demographic data and vital signs were taken before the ultrasound measurement done for inferior vena cava and abdominal aorta diameter. Once the volunteers donated their blood of approximately 450 mls; the measurements were repeated using the same methods. There were differences in IVC, abdominal aorta and inferior vena cava:aorta diameters index pre and post donation. With mathematical analysis, we suggested the number of IVC:Aorta index as 1.14±2SD with SD 0.18 as a cut off value for class 1 hypovolemic shock. The IVC:Aorta diameter index can be used as a parameter for detecting early phase (Class 1) of hypovolemic shock.
- 19 February 2016
- Published by Springer Nature in International Journal of Emergency Medicine
- Vol. 9 (1) , 1-6
Open AccessUltrasonographic assessment of inferior vena cava/abdominal aorta diameter index: a new approach of assessing hypovolemic shock class 1
We designed this study to expand the usage of ultrasound to detect early occurrence of hypovolemia. We explore the potential use of inferior vena cava (IVC) and abdominal aorta (AA) diameter index (IVC:AA) measured ultrasonographically to detect class 1 hypovolemic shock with blood loss less than 15%.ᅟ The aim of this study was to determine the changes in the diameter of inferior vena cava and abdominal aorta in blood donors by using ultrasound, pre and post blood donation. The result of the study would be further explorated to determine the inferior vena cava (IVC) abdominal aorta (Aorta) diameter index (IVC:Aorta). This was a prospective study done in the blood bank of a university hospital. Researcher was trained by a senior radiologist to assess inferior vena cava and abdominal aorta diameter. Fifty-two healthy blood donors were included in the study. Inclusion criteria were same with the blood bank criteria to donate blood. Demographic data and vital signs were taken before the ultrasound measurement done for inferior vena cava and abdominal aorta diameter. Once the volunteers donated their blood of approximately 450 mls; the measurements were repeated using the same methods. There were differences in IVC, abdominal aorta and inferior vena cava:aorta diameters index pre and post donation. With mathematical analysis, we suggested the number of IVC:Aorta index as 1.14±2SD with SD 0.18 as a cut off value for class 1 hypovolemic shock. The IVC:Aorta diameter index can be used as a parameter for detecting early phase (Class 1) of hypovolemic shock.
- 1 August 2015
- Published by Elsevier in Forensic Science International
- Vol. 253, 137.e1-137.e7
Practical relevance of prescribing superimposition for determining a frontal sinus pattern match
- 1 August 2015
- Published by Elsevier in Forensic Science International
- Vol. 253, 137.e1-137.e7
Practical relevance of prescribing superimposition for determining a frontal sinus pattern match
- 1 April 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 53-56
Ultrasonographic abdominal aorta diameter changes: A predictor of hypovolemic shock class 1
Hypovolemic shock class 1 and mild to moderate dehydration are associated with normal or minimal changes in vital signs. Biochemical values markedly change only in advanced hypovolemia. Inspiration and expiration inferior vena cava diameter changes predict hypovolemic shock class 1 but in acute emergencies this method is impractical. The purpose of this study is to develop a new approach in identifying hypovolemic shock at early phase (class 1 hypovolemic shock) by measuring the diameter of aorta using ultrasound machine.
- 1 April 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 53-56
Ultrasonographic abdominal aorta diameter changes: A predictor of hypovolemic shock class 1
Hypovolemic shock class 1 and mild to moderate dehydration are associated with normal or minimal changes in vital signs. Biochemical values markedly change only in advanced hypovolemia. Inspiration and expiration inferior vena cava diameter changes predict hypovolemic shock class 1 but in acute emergencies this method is impractical. The purpose of this study is to develop a new approach in identifying hypovolemic shock at early phase (class 1 hypovolemic shock) by measuring the diameter of aorta using ultrasound machine.