Guruprasad A. Giridharan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Guruprasad A. Giridharan has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
Mark S. Slaughter
Department of Cardiovascular and Thoracic Surgery, Cardiovascular Innovation Institute, University of Louisville, Louisville, KY, USA
4 shared publicationsMichael A. Sobieski
Department of Cardiovascular and Thoracic Surgery, Cardiovascular Innovation Institute, University of Louisville, Louisville, KY, USA
4 shared publicationsSteven C. Koenig
Department of Bioengineering, Cardiovascular Innovation Institute, University of Louisville, Louisville, KY, USA
4 shared publicationsYu Wang
Department of Biomedical Engineering, Faculty of Electronic Information and Electrical Engineering, Dalian University of Technology, Dalian, Liaoning, China
3 shared publications- Ayman El-Baz
Department of Bioengineering, University of Louisville, Louisville, KY 40292, USA
2 shared publications - Ahmed Atwan
Information Technology Department, Faculty of Computers and Information, Mansoura University, Mansoura 35516, Egypt
1 shared publication
Latest Publications
- Open Access
- 9 December 2021
- Published by MDPI AG in Diagnostics
- Vol. 11 (12) , 2313
Role of Optical Coherence Tomography Imaging in Predicting Progression of Age-Related Macular Disease: A Survey
In developed countries, age-related macular degeneration (AMD), a retinal disease, is the main cause of vision loss in the elderly. Optical Coherence Tomography (OCT) is currently the gold standard for assessing individuals for initial AMD diagnosis. In this paper, we look at how OCT imaging can be used to diagnose AMD. Our main aim is to examine and compare automated computer-aided diagnostic (CAD) systems for diagnosing and grading of AMD. We provide a brief summary, outlining the main aspects of performance assessment and providing a basis for current research in AMD diagnosis. As a result, the only viable alternative is to prevent AMD and stop both this devastating eye condition and unwanted visual impairment. On the other hand, the grading of AMD is very important in order to detect early AMD and prevent patients from reaching advanced AMD disease. In light of this, we explore the remaining issues with automated systems for AMD detection based on OCT imaging, as well as potential directions for diagnosis and monitoring systems based on OCT imaging and telemedicine applications.
- 9 December 2021
- Published by MDPI AG in Diagnostics
- Vol. 11 (12) , 2313
Open AccessRole of Optical Coherence Tomography Imaging in Predicting Progression of Age-Related Macular Disease: A Survey
In developed countries, age-related macular degeneration (AMD), a retinal disease, is the main cause of vision loss in the elderly. Optical Coherence Tomography (OCT) is currently the gold standard for assessing individuals for initial AMD diagnosis. In this paper, we look at how OCT imaging can be used to diagnose AMD. Our main aim is to examine and compare automated computer-aided diagnostic (CAD) systems for diagnosing and grading of AMD. We provide a brief summary, outlining the main aspects of performance assessment and providing a basis for current research in AMD diagnosis. As a result, the only viable alternative is to prevent AMD and stop both this devastating eye condition and unwanted visual impairment. On the other hand, the grading of AMD is very important in order to detect early AMD and prevent patients from reaching advanced AMD disease. In light of this, we explore the remaining issues with automated systems for AMD detection based on OCT imaging, as well as potential directions for diagnosis and monitoring systems based on OCT imaging and telemedicine applications.
- 13 July 2017
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 8 (4) , 439-452
Hemodynamic Benefits of Counterpulsation, Implantable, Percutaneous, and Intraaortic Rotary Blood Pumps: An In-Silico and In Vitro Study
Mechanical circulatory support (MCS) devices have become a standard therapy for heart failure (HF) patients. MCS device designs may differ by level of support, inflow and/or outflow cannulation sites, and mechanism(s) of cardiac unloading and blood flow delivery. Investigation and direct comparison of hemodynamic parameters that help characterize performance of MCS devices has been limited. We quantified cardiac and vascular hemodynamic responses for different types of MCS devices. Continuous flow (CF) left ventricular (LV) assist devices (LVAD) with LV or left atrial (LA) inlet, counterpulsation devices, percutaneous CF LVAD, and intra-aortic rotary blood pumps (IARBP) were quantified using established computer simulation and mock flow loop models. Hemodynamic data were analyzed on a beat-to-beat basis at baseline HF and over a range of MCS support. Results demonstrated that all LVAD greatly diminished vascular pulsatility (P) and LV external work (LVEW). LVAD with LA inflow provided a greater reduction in LVEW compared to LVAD with LV inflow, but at the potential risk for blood stasis/thrombosis in the LV at high support. Counterpulsation provided greater coronary flow (CoF) augmentation, but had a lower reduction in LVEW compared to partial percutaneous LVAD support. IARBP diminished LVEW, but at the expense of diminished CoF due to coronary steal. The hemodynamic benefits for each type of mechanical circulatory support system are unique and clinical decisions on device selection to maximize end organ perfusion and minimize invasiveness needs to be considered for an individual patients’ presentation.
- 13 July 2017
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 8 (4) , 439-452
Hemodynamic Benefits of Counterpulsation, Implantable, Percutaneous, and Intraaortic Rotary Blood Pumps: An In-Silico and In Vitro Study
Mechanical circulatory support (MCS) devices have become a standard therapy for heart failure (HF) patients. MCS device designs may differ by level of support, inflow and/or outflow cannulation sites, and mechanism(s) of cardiac unloading and blood flow delivery. Investigation and direct comparison of hemodynamic parameters that help characterize performance of MCS devices has been limited. We quantified cardiac and vascular hemodynamic responses for different types of MCS devices. Continuous flow (CF) left ventricular (LV) assist devices (LVAD) with LV or left atrial (LA) inlet, counterpulsation devices, percutaneous CF LVAD, and intra-aortic rotary blood pumps (IARBP) were quantified using established computer simulation and mock flow loop models. Hemodynamic data were analyzed on a beat-to-beat basis at baseline HF and over a range of MCS support. Results demonstrated that all LVAD greatly diminished vascular pulsatility (P) and LV external work (LVEW). LVAD with LA inflow provided a greater reduction in LVEW compared to LVAD with LV inflow, but at the potential risk for blood stasis/thrombosis in the LV at high support. Counterpulsation provided greater coronary flow (CoF) augmentation, but had a lower reduction in LVEW compared to partial percutaneous LVAD support. IARBP diminished LVEW, but at the expense of diminished CoF due to coronary steal. The hemodynamic benefits for each type of mechanical circulatory support system are unique and clinical decisions on device selection to maximize end organ perfusion and minimize invasiveness needs to be considered for an individual patients’ presentation.
- 1 March 2017
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 63 (2) , 134-138
Efficacy of Subcutaneous Electrocardiogram Leads for Synchronous Timing During Chronic Counterpulsation Therapy
Counterpulsation devices (CPDs) require an accurate, reliable electrocardiogram (ECG) waveform for triggering inflation and deflation. Surface electrodes are for short-term use, and transvenous/epicardial leads require invasive implant procedure. A subcutaneous ECG lead configuration was developed as an alternative approach for long-term use with timing mechanical circulatory support (MCS) devices. In this study, efficacy testing was completed by simultaneously recording ECG waveforms from clinical-grade epicardial (control) and subcutaneous (test) leads in chronic ischemic heart failure calves implanted with CPD for up to 30 days. Sensitivity and specificity of CPD triggering by R-wave detection was quantified for each lead configuration. The subcutaneous leads provided 98.9% positive predictive value and 98.9% sensitivity compared to the epicardial ECG leads. Lead migration (n = 1) and fracture (n = 1) were observed in only 2 of 40 implanted leads, without adversely impacting triggering efficacy due to lead redundancy. These findings demonstrate the efficacy of subcutaneous ECG leads for long-term CPD timing and potential use as an alternative method for MCS device timing.
- 1 March 2017
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 63 (2) , 134-138
Efficacy of Subcutaneous Electrocardiogram Leads for Synchronous Timing During Chronic Counterpulsation Therapy
Counterpulsation devices (CPDs) require an accurate, reliable electrocardiogram (ECG) waveform for triggering inflation and deflation. Surface electrodes are for short-term use, and transvenous/epicardial leads require invasive implant procedure. A subcutaneous ECG lead configuration was developed as an alternative approach for long-term use with timing mechanical circulatory support (MCS) devices. In this study, efficacy testing was completed by simultaneously recording ECG waveforms from clinical-grade epicardial (control) and subcutaneous (test) leads in chronic ischemic heart failure calves implanted with CPD for up to 30 days. Sensitivity and specificity of CPD triggering by R-wave detection was quantified for each lead configuration. The subcutaneous leads provided 98.9% positive predictive value and 98.9% sensitivity compared to the epicardial ECG leads. Lead migration (n = 1) and fracture (n = 1) were observed in only 2 of 40 implanted leads, without adversely impacting triggering efficacy due to lead redundancy. These findings demonstrate the efficacy of subcutaneous ECG leads for long-term CPD timing and potential use as an alternative method for MCS device timing.
- 1 March 2015
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 61 (2) , 170-177
Suction Prevention and Physiologic Control of Continuous Flow Left Ventricular Assist Devices Using Intrinsic Pump Parameters
The risk for left ventricular (LV) suction during left ventricular assist devices (LVAD) support has been a clinical concern. Current development efforts suggest LVAD suction prevention and physiologic control algorithms may require chronic implantation of pressure or flow sensors, which can be unreliable because of baseline drift and short lifespan. To overcome this limitation, we designed a sensorless suction prevention and physiologic control (eSPPC) algorithm that only requires LVAD intrinsic parameters (pump speed and power). Two gain-scheduled, proportional-integral controllers maintain a differential pump speed (ΔRPM) above a user-defined threshold to prevent LV suction while maintaining an average reference differential pressure (ΔP) between the LV and aorta. ΔRPM is calculated from noisy pump speed measurements that are low-pass filtered, and ΔP is estimated using an extended Kalman filter. Efficacy and robustness of the eSPPC algorithm were evaluated in silico during simulated rest and exercise test conditions for 1) excessive ΔP setpoint (ES); 2) rapid eightfold increase in pulmonary vascular resistance (PVR); and 3) ES and PVR. Simulated hemodynamic waveforms (LV pressure and volume; aortic pressure and flow) using only intrinsic pump parameters showed the feasibility of our proposed eSPPC algorithm in preventing LV suction for all test conditions.
- 1 March 2015
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 61 (2) , 170-177
Suction Prevention and Physiologic Control of Continuous Flow Left Ventricular Assist Devices Using Intrinsic Pump Parameters
The risk for left ventricular (LV) suction during left ventricular assist devices (LVAD) support has been a clinical concern. Current development efforts suggest LVAD suction prevention and physiologic control algorithms may require chronic implantation of pressure or flow sensors, which can be unreliable because of baseline drift and short lifespan. To overcome this limitation, we designed a sensorless suction prevention and physiologic control (eSPPC) algorithm that only requires LVAD intrinsic parameters (pump speed and power). Two gain-scheduled, proportional-integral controllers maintain a differential pump speed (ΔRPM) above a user-defined threshold to prevent LV suction while maintaining an average reference differential pressure (ΔP) between the LV and aorta. ΔRPM is calculated from noisy pump speed measurements that are low-pass filtered, and ΔP is estimated using an extended Kalman filter. Efficacy and robustness of the eSPPC algorithm were evaluated in silico during simulated rest and exercise test conditions for 1) excessive ΔP setpoint (ES); 2) rapid eightfold increase in pulmonary vascular resistance (PVR); and 3) ES and PVR. Simulated hemodynamic waveforms (LV pressure and volume; aortic pressure and flow) using only intrinsic pump parameters showed the feasibility of our proposed eSPPC algorithm in preventing LV suction for all test conditions.
- Open Access
- 2 February 2015
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 87 (4) , 2107-2113
Effects of Physiologic Mechanical Stimulation on Embryonic Chick Cardiomyocytes Using a Microfluidic Cardiac Cell Culture Model
Hemodynamic mechanical cues play a critical role in the early development and functional maturation of cardiomyocytes (CM). Therefore, tissue engineering approaches that incorporate immature CM into functional cardiac tissues capable of recovering or replacing damaged cardiac muscle require physiologically relevant environments to provide the appropriate mechanical cues. The goal of this work is to better understand the subcellular responses of immature cardiomyocytes using an in vitro cardiac cell culture model that realistically mimics in vivo mechanical conditions, including cyclical fluid flows, chamber pressures, and tissue strains that could be experienced by implanted cardiac tissues. Cardiomyocytes were cultured in a novel microfluidic cardiac cell culture model (CCCM) to achieve accurate replication of the mechanical cues experienced by ventricular CM. Day 10 chick embryonic ventricular CM (3.5 × 104 cell clusters per cell chamber) were cultured for 4 days in the CCCM under cyclic mechanical stimulation (10 mmHg, 8–15% stretch, 2 Hz frequency) and ventricular cells from the same embryo were cultured in a static condition for 4 days as controls. Additionally, ventricular cell suspensions and ventricular tissue from day 16 chick embryo were collected and analyzed for comparison with CCCM cultured CM. The gene expressions and protein synthesis of calcium handling proteins decreased significantly during the isolation process. Mechanical stimulation of the cultured CM using the CCCM resulted in an augmentation of gene expression and protein synthesis of calcium handling proteins compared to the 2D constructs cultured in the static conditions. Further, the CCCM conditioned 2D constructs have a higher beat rate and contractility response to isoproterenol. These results demonstrate that early mechanical stimulation of embryonic cardiac tissue is necessary for tissue proliferation and for protein synthesis of the calcium handling constituents required for tissue contractility. Thus, physiologic mechanical conditioning may be essential for generating functional cardiac patches for replacement of injured cardiac tissue.
- 2 February 2015
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 87 (4) , 2107-2113
Open AccessEffects of Physiologic Mechanical Stimulation on Embryonic Chick Cardiomyocytes Using a Microfluidic Cardiac Cell Culture Model
Hemodynamic mechanical cues play a critical role in the early development and functional maturation of cardiomyocytes (CM). Therefore, tissue engineering approaches that incorporate immature CM into functional cardiac tissues capable of recovering or replacing damaged cardiac muscle require physiologically relevant environments to provide the appropriate mechanical cues. The goal of this work is to better understand the subcellular responses of immature cardiomyocytes using an in vitro cardiac cell culture model that realistically mimics in vivo mechanical conditions, including cyclical fluid flows, chamber pressures, and tissue strains that could be experienced by implanted cardiac tissues. Cardiomyocytes were cultured in a novel microfluidic cardiac cell culture model (CCCM) to achieve accurate replication of the mechanical cues experienced by ventricular CM. Day 10 chick embryonic ventricular CM (3.5 × 104 cell clusters per cell chamber) were cultured for 4 days in the CCCM under cyclic mechanical stimulation (10 mmHg, 8–15% stretch, 2 Hz frequency) and ventricular cells from the same embryo were cultured in a static condition for 4 days as controls. Additionally, ventricular cell suspensions and ventricular tissue from day 16 chick embryo were collected and analyzed for comparison with CCCM cultured CM. The gene expressions and protein synthesis of calcium handling proteins decreased significantly during the isolation process. Mechanical stimulation of the cultured CM using the CCCM resulted in an augmentation of gene expression and protein synthesis of calcium handling proteins compared to the 2D constructs cultured in the static conditions. Further, the CCCM conditioned 2D constructs have a higher beat rate and contractility response to isoproterenol. These results demonstrate that early mechanical stimulation of embryonic cardiac tissue is necessary for tissue proliferation and for protein synthesis of the calcium handling constituents required for tissue contractility. Thus, physiologic mechanical conditioning may be essential for generating functional cardiac patches for replacement of injured cardiac tissue.
- 1 July 2013
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 59 (4) , 410-419
Fault Detection in Rotary Blood Pumps Using Motor Speed Response
Clinical acceptance of ventricular assist devices (VADs) as long-term heart failure therapy requires safe and effective circulatory support for a minimum of 5 years. Yet, VAD failure beyond 2 years of support is still a concern. Currently, device controllers cannot consistently predict VAD failure modes, and undetected VAD faults may lead to catastrophic device failure. To minimize this risk, a model-based algorithm for reliable VAD fault detection that only requires VAD revolutions per minute (rpm) was developed. The algorithm was tested using computer models of the human cardiovascular system simulating heart failure and axial flow (AF) or centrifugal flow (CF) VADs. Ventricular assist device rpm was monitored after a step down of motor current for normal and simulated fault conditions (>750 faults). The ability to detect fault conditions with 1%, 5%, and 10% rpm measurement noise was evaluated. All failure modes affected the VAD rpm responses to the motor current step down. Fault detection rates were >95% for AF and >89% for CF VADs, even with 10% rpm measurement noise. The VAD rpm responses were significantly altered by blood viscosity (3.5–6.2 cP), which should be accounted for in clinical application. The proposed VAD fault detection algorithm may deliver a convenient and nonintrusive way to minimize catastrophic device failures.
- 1 July 2013
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 59 (4) , 410-419
Fault Detection in Rotary Blood Pumps Using Motor Speed Response
Clinical acceptance of ventricular assist devices (VADs) as long-term heart failure therapy requires safe and effective circulatory support for a minimum of 5 years. Yet, VAD failure beyond 2 years of support is still a concern. Currently, device controllers cannot consistently predict VAD failure modes, and undetected VAD faults may lead to catastrophic device failure. To minimize this risk, a model-based algorithm for reliable VAD fault detection that only requires VAD revolutions per minute (rpm) was developed. The algorithm was tested using computer models of the human cardiovascular system simulating heart failure and axial flow (AF) or centrifugal flow (CF) VADs. Ventricular assist device rpm was monitored after a step down of motor current for normal and simulated fault conditions (>750 faults). The ability to detect fault conditions with 1%, 5%, and 10% rpm measurement noise was evaluated. All failure modes affected the VAD rpm responses to the motor current step down. Fault detection rates were >95% for AF and >89% for CF VADs, even with 10% rpm measurement noise. The VAD rpm responses were significantly altered by blood viscosity (3.5–6.2 cP), which should be accounted for in clinical application. The proposed VAD fault detection algorithm may deliver a convenient and nonintrusive way to minimize catastrophic device failures.
- 1 May 2013
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 59 (3) , 261-268
Flow Modulation Algorithms for Intra-Aortic Rotary Blood Pumps to Minimize Coronary Steal
Intra-aortic rotary blood pumps (IARBPs) have been used for partial cardiac support during cardiogenic shock, myocardial infarction, percutaneous coronary intervention, and potentially viable for long-term circulatory support. Intra-aortic rotary blood pump support continuously removes volume from the aortic root, which lowers left ventricular preload, external work (LVEW), and improves end-organ perfusion. However, IARBP support diminishes aortic root pressure and coronary artery. It may also create “coronary steal,” which may produce a myocardial hypoxic state adversely affecting patient outcomes. Our objective was to develop IARBP flow modulation algorithms to eliminate coronary steal and improve the myocardial supply-demand ratio without compromising the clinical benefits of restored end-organ perfusion and reduced LVEW. The hemodynamic responses of the native ventricle, coronary, and systemic vasculature to timing and synchronization of IARBP flow modulation (cyclic variation of pump flow) were investigated using a clinical heart failure (HF) computer simulation model. A total of more than 150 combinations of varying pulse widths and time-shifts to modulate IARBP flow were tested at mean IARBP flow rates of 2, 3, and 4 L/min, and compared with HF baseline values (no IARBP support). Increasing IARBP support augmented cardiac output and diminished LVEW. Nonmodulated IARBP support significantly diminished mean diastolic coronary flow (−49%) and myocardial supply-demand ratio (−12%) compared with HF baseline. Intra-aortic rotary blood pump flow modulation increased mean diastolic coronary flow (+17%) and myocardial supply-demand ratio (+24%) compared with nonmodulated IARBP (constant flow). Modulation and synchronization of IARBP support augmented coronary artery perfusion and myocardial supply-demand ratio in simulated clinical HF while also restoring end-organ perfusion and reducing LVEW. Implementation of IARBP support with flow modulation may prevent myocardial hypoxia and improve patient outcomes. However, even with flow modulation, IARBP support provides a smaller improvement in myocardial supply demand ratio compared to ventricular assist devices and intra-aortic balloon pumps.
- 1 May 2013
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 59 (3) , 261-268
Flow Modulation Algorithms for Intra-Aortic Rotary Blood Pumps to Minimize Coronary Steal
Intra-aortic rotary blood pumps (IARBPs) have been used for partial cardiac support during cardiogenic shock, myocardial infarction, percutaneous coronary intervention, and potentially viable for long-term circulatory support. Intra-aortic rotary blood pump support continuously removes volume from the aortic root, which lowers left ventricular preload, external work (LVEW), and improves end-organ perfusion. However, IARBP support diminishes aortic root pressure and coronary artery. It may also create “coronary steal,” which may produce a myocardial hypoxic state adversely affecting patient outcomes. Our objective was to develop IARBP flow modulation algorithms to eliminate coronary steal and improve the myocardial supply-demand ratio without compromising the clinical benefits of restored end-organ perfusion and reduced LVEW. The hemodynamic responses of the native ventricle, coronary, and systemic vasculature to timing and synchronization of IARBP flow modulation (cyclic variation of pump flow) were investigated using a clinical heart failure (HF) computer simulation model. A total of more than 150 combinations of varying pulse widths and time-shifts to modulate IARBP flow were tested at mean IARBP flow rates of 2, 3, and 4 L/min, and compared with HF baseline values (no IARBP support). Increasing IARBP support augmented cardiac output and diminished LVEW. Nonmodulated IARBP support significantly diminished mean diastolic coronary flow (−49%) and myocardial supply-demand ratio (−12%) compared with HF baseline. Intra-aortic rotary blood pump flow modulation increased mean diastolic coronary flow (+17%) and myocardial supply-demand ratio (+24%) compared with nonmodulated IARBP (constant flow). Modulation and synchronization of IARBP support augmented coronary artery perfusion and myocardial supply-demand ratio in simulated clinical HF while also restoring end-organ perfusion and reducing LVEW. Implementation of IARBP support with flow modulation may prevent myocardial hypoxia and improve patient outcomes. However, even with flow modulation, IARBP support provides a smaller improvement in myocardial supply demand ratio compared to ventricular assist devices and intra-aortic balloon pumps.