Numayer Andalib Zaman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Numayer Andalib Zaman has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Faysal Nayan
Department of Electrical and Electronic Engineering, Ahsanullah University of Science and Technology, Dhaka, Bangladesh
3 shared publications - Mahamudul Hassan Fuad
Department of Electrical & Electronic Engineering, Dhaka International University, Dhaka-1212, Bangladesh
2 shared publications - Ahmed Rayhan
Department of Electrical and Electronic Engineering, Ahsanullah University of Science and Technology, Dhaka, Bangladesh
1 shared publication - Arif Raihan
Department of Electrical and Electronic Engineering, Ahsanullah University of Science and Technology, Dhaka, Bangladesh
1 shared publication - Arif Raihan
Department of Electrical and Electronic Engineering, Ahsanullah University of Science and Technology, Dhaka, Bangladesh
1 shared publication Nur A Akash
Department of EEE, Faculty of Engineering, Ahsanullah University of Science and Technology (AUST), Bangladesh
1 shared publication
Latest Publications
- 18 July 2025
- Published by Springer Nature in Optical and Quantum Electronics
- Vol. 57 (8) , 1-25
Detection of tuberculosis in blood samples using one-dimensional photonic crystal
- 18 July 2025
- Published by Springer Nature in Optical and Quantum Electronics
- Vol. 57 (8) , 1-25
Detection of tuberculosis in blood samples using one-dimensional photonic crystal
- 1 February 2025
- Published by The Electrochemical Society in ECS Journal of Solid State Science and Technology
- Vol. 14 (2) , 027006
Simulation Analysis of a Highly Sensitive Biosensor for Early Detection of Cancer Cells Based on a 1D Photonic Crystal
A one-dimensional (1D) photonic crystal-based novel photonic biosensor is introduced for detecting cancerous cells that grow in different parts of the human body. The proposed sensor has been designed with an alternate arrangement of Si and CaF2 that has a defect layer in the middle of the structure. The widely known transfer matrix method has been utilized to compute the transmission spectra. The performance of the sensor is determined by the resonant wavelength shift in the transmission spectra by varying different parameters such as the angle of incidence and the thickness of the sample defect layer. Because each cell in the human body has a separate refractive index, performance parameters have been calculated separately for each type of cancer for accuracy. The reported sensor shows a high average sensitivity of 1705.82 nm per RIU for different cancerous cells. It also exhibits high quality factor (62216.41) and figure of limit (103,651.68 per RIU) with a very low detection limit (1.2945E-06 RIU). The proposed 1D structure has a compact design, is easy to fabricate, is cost effective and may be used in other biosensing applications as well.
- 1 February 2025
- Published by The Electrochemical Society in ECS Journal of Solid State Science and Technology
- Vol. 14 (2) , 027006
Simulation Analysis of a Highly Sensitive Biosensor for Early Detection of Cancer Cells Based on a 1D Photonic Crystal
A one-dimensional (1D) photonic crystal-based novel photonic biosensor is introduced for detecting cancerous cells that grow in different parts of the human body. The proposed sensor has been designed with an alternate arrangement of Si and CaF2 that has a defect layer in the middle of the structure. The widely known transfer matrix method has been utilized to compute the transmission spectra. The performance of the sensor is determined by the resonant wavelength shift in the transmission spectra by varying different parameters such as the angle of incidence and the thickness of the sample defect layer. Because each cell in the human body has a separate refractive index, performance parameters have been calculated separately for each type of cancer for accuracy. The reported sensor shows a high average sensitivity of 1705.82 nm per RIU for different cancerous cells. It also exhibits high quality factor (62216.41) and figure of limit (103,651.68 per RIU) with a very low detection limit (1.2945E-06 RIU). The proposed 1D structure has a compact design, is easy to fabricate, is cost effective and may be used in other biosensing applications as well.
- 23 November 2024
- Published by Springer Nature in Optical and Quantum Electronics
- Vol. 56 (12) , 1-25
A high-performance biosensor based on one-dimensional photonic crystal for the detection of cancer cells
- 23 November 2024
- Published by Springer Nature in Optical and Quantum Electronics
- Vol. 56 (12) , 1-25
A high-performance biosensor based on one-dimensional photonic crystal for the detection of cancer cells
- 20 July 2023
- Published by IOP Publishing in Physica Scripta
- Vol. 98 (8) , 085518
A high-performance biosensor design for waterborne bacteria detection based on one-dimensional photonic crystal
One of the global challenges nowadays is detecting and removing the waterborne bacteria from drinking water. In this work, we propose a one-dimensional photonic crystal based on Si/SiO2 layers containing a defect layer in the middle of the structure to detect waterborne bacteria. The findings have been formulated using the transfer matrix method, where the sensor mechanism is based on the variation of the refractive index of different bacteria samples from that of pure water. The impact of various parameters like the angle of incidence, the thickness of the defect layer, and the number of periods of the structure are studied to find the optimized condition. The sensor shows high sensitivity of 2486.57 nm RIU that can detect minimal changes of defect mode peak inside the photonic bandgap of the transmission spectra. Other performance parameters such as the quality factor (5455.70), figure of merit (6262.31 RIU−1), and limit of detection (2.72×10−05 RIU) have also been calculated to get a deeper understanding of the sensor’s capabilities. Therefore, the simplicity and excellent performance make our design efficient for any sensing application as well as fabrication process.
- 20 July 2023
- Published by IOP Publishing in Physica Scripta
- Vol. 98 (8) , 085518
A high-performance biosensor design for waterborne bacteria detection based on one-dimensional photonic crystal
One of the global challenges nowadays is detecting and removing the waterborne bacteria from drinking water. In this work, we propose a one-dimensional photonic crystal based on Si/SiO2 layers containing a defect layer in the middle of the structure to detect waterborne bacteria. The findings have been formulated using the transfer matrix method, where the sensor mechanism is based on the variation of the refractive index of different bacteria samples from that of pure water. The impact of various parameters like the angle of incidence, the thickness of the defect layer, and the number of periods of the structure are studied to find the optimized condition. The sensor shows high sensitivity of 2486.57 nm RIU that can detect minimal changes of defect mode peak inside the photonic bandgap of the transmission spectra. Other performance parameters such as the quality factor (5455.70), figure of merit (6262.31 RIU−1), and limit of detection (2.72×10−05 RIU) have also been calculated to get a deeper understanding of the sensor’s capabilities. Therefore, the simplicity and excellent performance make our design efficient for any sensing application as well as fabrication process.