APAnil Kumar Pandey

Anil Kumar Pandey

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Anil Kumar Pandey has a total of 11 co-authors. Here are the top co-authors by number of shared publications:

  • Rakesh Kumar

    Department of Nuclear Medicine, All India Institute of Medical Sciences, Ansari Nagar, New Delhi, India

    2 shared publications
  • Abhishek Behera

    Department of Nuclear Medicine, All India Institute of Medical Sciences, Ansari Nagar, New Delhi, India

    1 shared publication
  • Akshima Sharma

    A.I.I.M.S.

    1 shared publication
  • C. S. Bal

    A.I.I.M.S.

    1 shared publication
  • Chandrashekhar Bal

    Department of Nuclear Medicine, All India Institute of Medical Sciences, Ansari Nagar, New Delhi, India

    1 shared publication
  • Chetan Patel

    Department of Nuclear Medicine, All India Institute of Medical Sciences, Ansari Nagar, New Delhi, India

    1 shared publication

Latest Publications

  • Open Access

    Development and validation of the suprathreshold stochastic resonance-based image processing method for the detection of abdomino-pelvic tumor on PET/CT scans

    by Anil Kumar Pandey, Kartik Saroha, Param Dev Sharma, Abhishek Behera, Chetan Patel, Chandrashekhar Bal, Rakesh Kumar

    Purpose: The detection of abdomino-pelvic tumors embedded in or nearby radioactive urine containing 18F-FDG activity is a challenging task on PET/CT scan. In this study, we propose and validate the suprathreshold stochastic resonance-based image processing method for the detection of these tumors. Methods: The method consists of the addition of noise to the input image, and then thresholding it that creates one frame of intermediate image. One hundred such frames were generated and averaged to get the final image. The method was implemented using MATLAB R2013b on a personal computer. Noisy image was generated using random Poisson variates corresponding to each pixel of the input image. In order to verify the method, 30 sets of pre-diuretic and its corresponding post-diuretic PET/CT scan images (25 tumor images and 5 control images with no tumor) were included. For each sets of pre-diuretic image (input image), 26 images (at threshold values equal to mean counts multiplied by a constant factor ranging from 1.0 to 2.6 with increment step of 0.1) were created and visually inspected, and the image that most closely matched with the gold standard (corresponding post-diuretic image) was selected as the final output image. These images were further evaluated by two nuclear medicine physicians. Results: In 22 out of 25 images, tumor was successfully detected. In five control images, no false positives were reported. Thus, the empirical probability of detection of abdomino-pelvic tumors evaluates to 0.88. Conclusion: The proposed method was able to detect abdomino-pelvic tumors on pre-diuretic PET/CT scan with a high probability of success and no false positives.


  • Image Noise Removal Using Principle of Suprathreshold Stochastic Resonance

    by Anil K. Pandey, ParamDev Sharma, S. K. Sharma, Kaushik Sarkar, Akshima Sharma, Rakesh Kumar, C. S. Bal