Anil Kumar Pandey
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Anil Kumar Pandey has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Rakesh Kumar
Department of Nuclear Medicine, All India Institute of Medical Sciences, Ansari Nagar, New Delhi, India
2 shared publicationsAbhishek Behera
Department of Nuclear Medicine, All India Institute of Medical Sciences, Ansari Nagar, New Delhi, India
1 shared publicationAkshima Sharma
A.I.I.M.S.
1 shared publicationC. S. Bal
A.I.I.M.S.
1 shared publicationChandrashekhar Bal
Department of Nuclear Medicine, All India Institute of Medical Sciences, Ansari Nagar, New Delhi, India
1 shared publicationChetan Patel
Department of Nuclear Medicine, All India Institute of Medical Sciences, Ansari Nagar, New Delhi, India
1 shared publication
Latest Publications
- Open Access
- 1 January 2017
- Published by Scientific Scholar in Indian Journal of Nuclear Medicine
- Vol. 32 (2) , 103-109
Development and validation of the suprathreshold stochastic resonance-based image processing method for the detection of abdomino-pelvic tumor on PET/CT scans
Purpose: The detection of abdomino-pelvic tumors embedded in or nearby radioactive urine containing 18F-FDG activity is a challenging task on PET/CT scan. In this study, we propose and validate the suprathreshold stochastic resonance-based image processing method for the detection of these tumors. Methods: The method consists of the addition of noise to the input image, and then thresholding it that creates one frame of intermediate image. One hundred such frames were generated and averaged to get the final image. The method was implemented using MATLAB R2013b on a personal computer. Noisy image was generated using random Poisson variates corresponding to each pixel of the input image. In order to verify the method, 30 sets of pre-diuretic and its corresponding post-diuretic PET/CT scan images (25 tumor images and 5 control images with no tumor) were included. For each sets of pre-diuretic image (input image), 26 images (at threshold values equal to mean counts multiplied by a constant factor ranging from 1.0 to 2.6 with increment step of 0.1) were created and visually inspected, and the image that most closely matched with the gold standard (corresponding post-diuretic image) was selected as the final output image. These images were further evaluated by two nuclear medicine physicians. Results: In 22 out of 25 images, tumor was successfully detected. In five control images, no false positives were reported. Thus, the empirical probability of detection of abdomino-pelvic tumors evaluates to 0.88. Conclusion: The proposed method was able to detect abdomino-pelvic tumors on pre-diuretic PET/CT scan with a high probability of success and no false positives.
- 1 January 2017
- Published by Scientific Scholar in Indian Journal of Nuclear Medicine
- Vol. 32 (2) , 103-109
Open AccessDevelopment and validation of the suprathreshold stochastic resonance-based image processing method for the detection of abdomino-pelvic tumor on PET/CT scans
Purpose: The detection of abdomino-pelvic tumors embedded in or nearby radioactive urine containing 18F-FDG activity is a challenging task on PET/CT scan. In this study, we propose and validate the suprathreshold stochastic resonance-based image processing method for the detection of these tumors. Methods: The method consists of the addition of noise to the input image, and then thresholding it that creates one frame of intermediate image. One hundred such frames were generated and averaged to get the final image. The method was implemented using MATLAB R2013b on a personal computer. Noisy image was generated using random Poisson variates corresponding to each pixel of the input image. In order to verify the method, 30 sets of pre-diuretic and its corresponding post-diuretic PET/CT scan images (25 tumor images and 5 control images with no tumor) were included. For each sets of pre-diuretic image (input image), 26 images (at threshold values equal to mean counts multiplied by a constant factor ranging from 1.0 to 2.6 with increment step of 0.1) were created and visually inspected, and the image that most closely matched with the gold standard (corresponding post-diuretic image) was selected as the final output image. These images were further evaluated by two nuclear medicine physicians. Results: In 22 out of 25 images, tumor was successfully detected. In five control images, no false positives were reported. Thus, the empirical probability of detection of abdomino-pelvic tumors evaluates to 0.88. Conclusion: The proposed method was able to detect abdomino-pelvic tumors on pre-diuretic PET/CT scan with a high probability of success and no false positives.
- 18 March 2015
- Published by Springer Nature
- p. 507-514
Image Noise Removal Using Principle of Suprathreshold Stochastic Resonance
- 18 March 2015
- Published by Springer Nature
- p. 507-514
Image Noise Removal Using Principle of Suprathreshold Stochastic Resonance