Ahmed El-Olemy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ahmed El-Olemy has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Ahmed Emad F. Abbas
Analytical Chemistry Department, Faculty of Pharmacy, October 6 University, 6 October City, Egypt
3 shared publications - Sherif Mohamed Eid
Analytical Chemistry Department, Faculty of Pharmacy, October 6 University, Giza, Egypt
3 shared publications - Khalid A. M. Attia
Al-Azhar University, Faculty of Pharmacy, Pharmaceutical Analytical Chemistry Department , 11751 Nasr City, Cairo, Egypt
2 shared publications - Ahmed Serag
Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Al-Azhar University, Nasr City 11751, Cairo, Egypt
1 shared publication Khadiga M. Kelani
Analytical Chemistry Department, Faculty of Pharmacy Cairo University Cairo Egypt
1 shared publicationKhalid A.M. Attia
Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Al-Azhar University, 11751 Nasr City, Cairo, Egypt
1 shared publication
Latest Publications
- 7 August 2024
- Published by Wiley in Luminescence
- Vol. 39 (8) , e4837
An ultrasensitive green synchronous factorized spectrofluorimetric approach for the simultaneous determination of Favipiravir and Molnupiravir: Application to pharmaceutical, environmental, and biological matrices
During the pandemic, Favipiravir (FVP) and Molnupiravir (MPV) have been widely used for COVID‐19 treatment, leading to their presence in the environment. A green synchronous spectrofluorimetric method was developed to simultaneously detect them in environmental water, human plasma, and binary mixtures. Maximum fluorescence intensity was achieved at pH 8, with MPV exhibiting two peaks at 300 and 430 nm, and FVP showing one peak at 430 nm. A fluorescence subtraction method effectively removed interference, enabling direct determination of MPV at 300 nm and FVP at 430 nm. The method showed linearity within 2–13 ng/mL for FVP and 50–600 ng/mL for MPV, with recoveries of 100.35% and 100.12%, respectively. Limits of detection and quantification were 0.19 and 0.57 ng/mL for FVP and 10.52 and 31.88 ng/mL for MPV. Validation according to ICH and FDA guidelines yielded acceptable results. The method demonstrated good recoveries of FVP and MPV in pharmaceuticals, tap water and Nile water (99.62% ± 0.96% and 99.69% ± 0.64%) as per ICH guidelines and spiked human plasma (94.87% ± 2.111% and 94.79% ± 1.605%) following FDA guidelines, respectively. Its environmental friendliness was assessed using Green Analytical Procedure Index (GAPI) and the Analytical Greenness Metric (AGREE) tools.
- 7 August 2024
- Published by Wiley in Luminescence
- Vol. 39 (8) , e4837
An ultrasensitive green synchronous factorized spectrofluorimetric approach for the simultaneous determination of Favipiravir and Molnupiravir: Application to pharmaceutical, environmental, and biological matrices
During the pandemic, Favipiravir (FVP) and Molnupiravir (MPV) have been widely used for COVID‐19 treatment, leading to their presence in the environment. A green synchronous spectrofluorimetric method was developed to simultaneously detect them in environmental water, human plasma, and binary mixtures. Maximum fluorescence intensity was achieved at pH 8, with MPV exhibiting two peaks at 300 and 430 nm, and FVP showing one peak at 430 nm. A fluorescence subtraction method effectively removed interference, enabling direct determination of MPV at 300 nm and FVP at 430 nm. The method showed linearity within 2–13 ng/mL for FVP and 50–600 ng/mL for MPV, with recoveries of 100.35% and 100.12%, respectively. Limits of detection and quantification were 0.19 and 0.57 ng/mL for FVP and 10.52 and 31.88 ng/mL for MPV. Validation according to ICH and FDA guidelines yielded acceptable results. The method demonstrated good recoveries of FVP and MPV in pharmaceuticals, tap water and Nile water (99.62% ± 0.96% and 99.69% ± 0.64%) as per ICH guidelines and spiked human plasma (94.87% ± 2.111% and 94.79% ± 1.605%) following FDA guidelines, respectively. Its environmental friendliness was assessed using Green Analytical Procedure Index (GAPI) and the Analytical Greenness Metric (AGREE) tools.
- 26 July 2023
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 107 (1) , 146-157
A Green-and-White Integrative Analytical Strategy Combining Univariate and Chemometric Techniques for Quantifying Recently Approved Multi-Drug Eye Solution and Potentially Cancer-Causing Impurities: Application to the Aqueous Humor
Drug impurities are now seen as a major threat to the production of pharmaceuticals around the world and a major part of the global contamination problem, especially when it comes to carcinogenic impurities. we present the first spectrophotometric strategy based on a combination of univariate and multivariate methods as impurity profiling methods for the estimation of lignocaine (LIG) and fluorescein (FLS) with their carcinogenic impurities: 2,6-xylidine (XYL) and benzene-1,3-diol (BZD). The data processing strategy depends on overcoming unresolved bands by employing five affordable, accurate, selective, and sensitive methods. The methods applied were a direct UV univariate spectrophotometric analysis (D0) and four multivariate chemometric methods including, classical least squares (CLS), Principal component regression (PCR), Partial least squares (PLS), and genetic algorithm (GA-PLS). FLS analysis (1–16 μg/mL) was performed using the D0 method at 478 nm; then, the application of the ratio subtraction method (RSM) allowed the removal of interference caused by the FLS spectrum. From the resulting ratio spectra, LIG, XYL, and BZD can be efficiently determined by chemometrics. The calibration set was carefully selected at 5 concentration levels utilizing a partial factorial training design, resulting in 25 mixtures with central levels of 160, 40, and 3 μg/mL for LIG, XYL, and BZD, respectively. Another 13 samples were applied to validate the predictive ability. The statistical parameters demonstrated exceptional recoveries and smaller prediction errors, confirming the experimental model's predictive power. The proposed approach was effectively tested using newly FDA-approved LIG and FLS pharmaceutical preparation and aqueous humour. Additionally, it was effectively assessed for whiteness, greenness, and sustainability using five assessment tools. With its remarkable analytical performance, sustainability, affordability, simplicity, and cost-efficiency, the proposed strategy is an indispensable tool for quality control and in-situ analysis in little-equipped labs, increasing the proposed approach's surveillance ability.
- 26 July 2023
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 107 (1) , 146-157
A Green-and-White Integrative Analytical Strategy Combining Univariate and Chemometric Techniques for Quantifying Recently Approved Multi-Drug Eye Solution and Potentially Cancer-Causing Impurities: Application to the Aqueous Humor
Drug impurities are now seen as a major threat to the production of pharmaceuticals around the world and a major part of the global contamination problem, especially when it comes to carcinogenic impurities. we present the first spectrophotometric strategy based on a combination of univariate and multivariate methods as impurity profiling methods for the estimation of lignocaine (LIG) and fluorescein (FLS) with their carcinogenic impurities: 2,6-xylidine (XYL) and benzene-1,3-diol (BZD). The data processing strategy depends on overcoming unresolved bands by employing five affordable, accurate, selective, and sensitive methods. The methods applied were a direct UV univariate spectrophotometric analysis (D0) and four multivariate chemometric methods including, classical least squares (CLS), Principal component regression (PCR), Partial least squares (PLS), and genetic algorithm (GA-PLS). FLS analysis (1–16 μg/mL) was performed using the D0 method at 478 nm; then, the application of the ratio subtraction method (RSM) allowed the removal of interference caused by the FLS spectrum. From the resulting ratio spectra, LIG, XYL, and BZD can be efficiently determined by chemometrics. The calibration set was carefully selected at 5 concentration levels utilizing a partial factorial training design, resulting in 25 mixtures with central levels of 160, 40, and 3 μg/mL for LIG, XYL, and BZD, respectively. Another 13 samples were applied to validate the predictive ability. The statistical parameters demonstrated exceptional recoveries and smaller prediction errors, confirming the experimental model's predictive power. The proposed approach was effectively tested using newly FDA-approved LIG and FLS pharmaceutical preparation and aqueous humour. Additionally, it was effectively assessed for whiteness, greenness, and sustainability using five assessment tools. With its remarkable analytical performance, sustainability, affordability, simplicity, and cost-efficiency, the proposed strategy is an indispensable tool for quality control and in-situ analysis in little-equipped labs, increasing the proposed approach's surveillance ability.
- 16 July 2023
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 302, 123161
Environmentally sustainable DRS-FTIR probe assisted by chemometric tools for quality control analysis of cinnarizine and piracetam having diverged concentration ranges: Validation, greenness, and whiteness studies
- 16 July 2023
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 302, 123161
Environmentally sustainable DRS-FTIR probe assisted by chemometric tools for quality control analysis of cinnarizine and piracetam having diverged concentration ranges: Validation, greenness, and whiteness studies
- Open Access
- 1 January 2023
- Published by Elsevier in SSRN Electronic Journal
An Innovative Nanoparticle-Modified Carbon Paste Sensor for Ultrasensitive Detection of Lignocaine and its Extremely Carcinogenic Metabolite Residues in Bovine Food Samples: Application of Nemi, Esa, Agree, Complexgapi, and Rgb12 Algorithms
Nowadays, veterinary medicine residues have been viewed as a major threat to food safety worldwide, especially when dealing with carcinogenic residues. Herein, we present the first differential pulse voltammetric method for the quantification of lignocaine and its carcinogenic metabolite 2,6-xylidine residues in bovine food samples, aided by five greenness and whiteness assessment tools, including NEMI, ESA, ComplexGAPI, AGREE, and RGB12. The method is depending on the electrochemical oxidation after modification of the carbon paste sensor with recycled Al2O3-NPs functionalized multi-walled carbon nanoparticles. The produced sensor (Al2O3-NPs/MWCNTs/CPE) was characterized using XRD, FT-IR, EDX, SEM, and TEM. As expected, the active surface area and electron transfer processes were accelerated by the modification, resulting in ultra-sensitive quantification with detection limits of 19.00 and 13.94 nM for lignocaine and 2,6-xylidine, respectively. In terms of greenness, whiteness, sustainability, analytical effectiveness, and economic and practical considerations, the proposed method outperforms the reported methods.
- 1 January 2023
- Published by Elsevier in SSRN Electronic Journal
Open AccessAn Innovative Nanoparticle-Modified Carbon Paste Sensor for Ultrasensitive Detection of Lignocaine and its Extremely Carcinogenic Metabolite Residues in Bovine Food Samples: Application of Nemi, Esa, Agree, Complexgapi, and Rgb12 Algorithms
Nowadays, veterinary medicine residues have been viewed as a major threat to food safety worldwide, especially when dealing with carcinogenic residues. Herein, we present the first differential pulse voltammetric method for the quantification of lignocaine and its carcinogenic metabolite 2,6-xylidine residues in bovine food samples, aided by five greenness and whiteness assessment tools, including NEMI, ESA, ComplexGAPI, AGREE, and RGB12. The method is depending on the electrochemical oxidation after modification of the carbon paste sensor with recycled Al2O3-NPs functionalized multi-walled carbon nanoparticles. The produced sensor (Al2O3-NPs/MWCNTs/CPE) was characterized using XRD, FT-IR, EDX, SEM, and TEM. As expected, the active surface area and electron transfer processes were accelerated by the modification, resulting in ultra-sensitive quantification with detection limits of 19.00 and 13.94 nM for lignocaine and 2,6-xylidine, respectively. In terms of greenness, whiteness, sustainability, analytical effectiveness, and economic and practical considerations, the proposed method outperforms the reported methods.