Antonio Pagano
Antonio Pagano has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Concetta Pirozzi
Emergency department, San Paolo Hospital, Neaples, Italy
1 shared publication- Concetta Pirozzi
Emergency Department of Arzignano Hospital, AULSS 8 Berica, Via Parco 1, 36071, Arzignano, Vicenza, Italy
1 shared publication Fabio Giuliano Numis
Emergency department, San Paolo Hospital, Neaples, Italy
1 shared publication- Fabio Giuliano Numis
UOC Pronto Soccorso-Medicina d’Urgenza, Ospedale S. Paolo, Napoli, Italy
1 shared publication Fernando Schiraldi
Emergency department, San Paolo Hospital, Neaples, Italy
1 shared publication- Fernando Schiraldi
Emergency Dept San Paolo Hospital, Via Terracina, 80125 Naples, Italy
1 shared publication
Latest Publications
- 7 September 2015
- Published by Springer Nature in Internal and Emergency Medicine
- Vol. 10 (7) , 851-854
Lung ultrasound for diagnosis of pneumonia in emergency department
Lung ultrasound (LUS) in the emergency department (ED) has shown a significant role in the diagnostic workup of pulmonary edema, pneumothorax and pleural effusions. The aim of this study is to assess the reliability of LUS for the diagnosis of acute pneumonia compared to chest X-ray (CXR) study. The study was conducted from September 2013 to March 2015. 107 patients were admitted to the ED with a clinical appearance of pneumonia. All the patients underwent a CXR study, read by a radiologist, and an LUS, performed by a trained ED physician on duty. Among the 105 patients, 68 were given a final diagnosis of pneumonia. We found a sensitivity of 0.985 and a specificity of 0.649 for LUS, and a sensitivity of 0.735 and specificity of 0.595 for CXR. The positive predictive value for LUS was 0.838 against 0.7 for CXR. The negative predictive value of LUS was 0.960 versus 0.550 for CXR. This study has shown sensitivity, positive predictive value and negative predictive value of LUS compared to the CXR study for the diagnosis of acute pneumonia. These results suggest the use of bedside thoracic US first-line diagnostic tool in patients with suspected pneumonia.
- 7 September 2015
- Published by Springer Nature in Internal and Emergency Medicine
- Vol. 10 (7) , 851-854
Lung ultrasound for diagnosis of pneumonia in emergency department
Lung ultrasound (LUS) in the emergency department (ED) has shown a significant role in the diagnostic workup of pulmonary edema, pneumothorax and pleural effusions. The aim of this study is to assess the reliability of LUS for the diagnosis of acute pneumonia compared to chest X-ray (CXR) study. The study was conducted from September 2013 to March 2015. 107 patients were admitted to the ED with a clinical appearance of pneumonia. All the patients underwent a CXR study, read by a radiologist, and an LUS, performed by a trained ED physician on duty. Among the 105 patients, 68 were given a final diagnosis of pneumonia. We found a sensitivity of 0.985 and a specificity of 0.649 for LUS, and a sensitivity of 0.735 and specificity of 0.595 for CXR. The positive predictive value for LUS was 0.838 against 0.7 for CXR. The negative predictive value of LUS was 0.960 versus 0.550 for CXR. This study has shown sensitivity, positive predictive value and negative predictive value of LUS compared to the CXR study for the diagnosis of acute pneumonia. These results suggest the use of bedside thoracic US first-line diagnostic tool in patients with suspected pneumonia.
- Open Access
- 27 April 2014
- Published by Springer Nature in The Ultrasound Journal
- Vol. 6 (1) , 5
Immediate versus delayed integrated point-of-care-ultrasonography to manage acute dyspnea in the emergency department
Background: Dyspnea is one of the most frequent complaints in the Emergency Department. Thoracic ultrasound should help to differentiate cardiogenic from non-cardiogenic causes of dyspnea. We evaluated whether the diagnostic accuracy can be improved by adding a point-of-care-ultrasonography (POC-US) to routine exams and if an early use of this technique produces any advantage. Methods: One hundred sixty-eight patients were enrolled and randomized in two groups: Group 1 received an immediate POC-US in addition to routine laboratory and instrumental tests; group 2 received an ultrasound scan within 1 h from the admission to the Emergency Department. The concordance between initial and final diagnosis and the percentage of wrong diagnosis in the two groups were evaluated. Mortality, days of hospitalization in Emergency Medicine department and transfers to other wards were compared. Sensitivity and specificity of the routine protocol and the one including ultrasonography for the diagnosis of the causes of dyspnea were also analyzed. Results: Eighty-eight patients were randomized in group 1 and 80 in group 2. The concordance rate between initial and final diagnoses was significantly different (0.94 in group 1 vs. 0.22 in group 2, p < 0.005). The percentage of wrong initial diagnosis was 5% in group 1 and 50% in group 2 (p < 0.0001). Conclusions: Adding POC-US to routine exams improves the diagnostic accuracy of dyspnea and reduces errors in the Emergency Department.
- 27 April 2014
- Published by Springer Nature in The Ultrasound Journal
- Vol. 6 (1) , 5
Open AccessImmediate versus delayed integrated point-of-care-ultrasonography to manage acute dyspnea in the emergency department
Background: Dyspnea is one of the most frequent complaints in the Emergency Department. Thoracic ultrasound should help to differentiate cardiogenic from non-cardiogenic causes of dyspnea. We evaluated whether the diagnostic accuracy can be improved by adding a point-of-care-ultrasonography (POC-US) to routine exams and if an early use of this technique produces any advantage. Methods: One hundred sixty-eight patients were enrolled and randomized in two groups: Group 1 received an immediate POC-US in addition to routine laboratory and instrumental tests; group 2 received an ultrasound scan within 1 h from the admission to the Emergency Department. The concordance between initial and final diagnosis and the percentage of wrong diagnosis in the two groups were evaluated. Mortality, days of hospitalization in Emergency Medicine department and transfers to other wards were compared. Sensitivity and specificity of the routine protocol and the one including ultrasonography for the diagnosis of the causes of dyspnea were also analyzed. Results: Eighty-eight patients were randomized in group 1 and 80 in group 2. The concordance rate between initial and final diagnoses was significantly different (0.94 in group 1 vs. 0.22 in group 2, p < 0.005). The percentage of wrong initial diagnosis was 5% in group 1 and 50% in group 2 (p < 0.0001). Conclusions: Adding POC-US to routine exams improves the diagnostic accuracy of dyspnea and reduces errors in the Emergency Department.