JHJoo-Yong Hahn

Joo-Yong Hahn

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Joo-Yong Hahn has a total of 24 co-authors. Here are the top co-authors by number of shared publications:

  • Jeong Hoon Yang

    Division of Cardiology, Department of Medicine, Heart Vascular Stroke Institute, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea

    2 shared publications
  • Jin-Ho Choi

    Emergency Medicine and Cardiovascular Imaging Center, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea

    2 shared publications
  • Kiick Sung

    Department of Thoracic and Cardiovascular Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea

    2 shared publications
  • Seung-Hyuk Choi

    Division of Cardiology, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul

    2 shared publications
  • Taek Kyu Park

    Division of Cardiology, Department of Medicine, Heart Vascular Stroke Institute, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea

    2 shared publications
  • Young Bin Song

    Division of Cardiology, Department of Medicine, Heart Vascular Stroke Institute, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea

    2 shared publications

Latest Publications

  • Open Access

    The Development of a Permanent Implantable Spacer with the Function of Size Adjustability for Customized Treatment of Regurgitant Heart Valve Disease

    by Min-Ku Chon, Su-Jin Jung, Jae-Young Seo, Dong-Hoon Shin, Jun-Hui Park, Hyun-Sook Kim, Joo-Yong Hahn, Eun-Kyoung Kim, Seung-Whan Lee, Yong-Hyun Park, et al.

    The Pivot Mandu is an innovative device featuring a leak-tight adjustable 3D balloon spacer, incorporating inner mesh support, an outer e-PTFE layer, and a compliant balloon in the middle layer with a specialized detachable system. To assess its feasibility, proof of concept was rigorously evaluated through bench testing and survival porcine animal experiments. The results demonstrated successful remote inflation of the balloon system, with the balloon spacer exhibiting sustained patent and functional integrity over an extended observation period of up to 6 months. A noteworthy feature of the newly designed 3D balloon spacer is its capability for easy size adjustment during procedures, enhancing its adaptability and practicality in clinical settings. This three-layered 3D balloon spacer, with its established long-term patency, exhibits highly encouraging outcomes that hold promise in overcoming the current limitations of spacer devices for heart valve diseases. Given the compelling results from preclinical investigations, the translation of the Pivot Mandu into human trials is strongly warranted.


  • Open Access

    The association of findings on brain computed tomography with neurologic outcomes following extracorporeal cardiopulmonary resuscitation

    by Jeong-Am Ryu, Chi Ryang Chung, Yang Hyun Cho, Kiick Sung, Gee Young Suh, Taek Kyu Park, Young Bin Song, Joo-Yong Hahn, Jin-Ho Choi, Hyeon-Cheol Gwon, et al.

    Limited data are available on imaging predictors of neurological outcomes after extracorporeal cardiopulmonary resuscitation (ECPR). We investigated the association of initial brain computed tomography (CT) findings with neurological outcomes following ECPR. Between February 2005 and December 2015, a total of 42 patients who underwent brain CT scans within 48 h after ECPR were analyzed. Loss of the boundary between gray matter and white matter (LOB) or cortical sulcal effacement (SE), gray-to-white matter ratio (GWR), and optic nerve sheath diameter (ONSD) were measured on initial brain CT. The primary outcome was the Cerebral Performance Categories (CPC) scale at discharge. Of the 42 adult ECPR patients, 23 (54.8%) patients survived to discharge and 19 (45.2%) patients had good neurological outcomes (CPC 1 and 2). The area under the curve (AUC) of GWR in the basal ganglia (GWR-BG) was 0.792 (95% confidence interval (CI), 0.639–0.901, p = 0.001). ONSD (AUC 0.745; 95% CI, 0.587 – 0.867, p = 0.007) was 5.57 (interquartile range (IQR) 5.14 – 5.98) mm in the good neurological outcome group versus 6.07 (IQR 5.71 – 6.64) mm in the poor outcome group. LOB or SE were more often detected in the poor neurological outcome group (AUC 0.817; 95% CI, 0.682–0.952, p <0.001). The predictive performance of poor neurological outcomes of a composite of GWR-BG, ONSD, and LOB/SE was significantly improved (AUC 0.904; 95% CI, 0.773–0.973) compared to when each brain CT marker was considered separately (GWR-BG, p = 0.048; ONSD, p = 0.026; LOB/SE, p = 0.028). GWR, ONSD, and LOB/SE on initial brain CT scans are associated with neurological prognosis in patients who underwent ECPR. The new risk prediction model, which uses a composite of GWR, ONCD, and LOB/SE, could provide better information on neurologic outcomes in patients underwent ECPR.


  • Open Access

    Clinical impact of intra-aortic balloon pump during extracorporeal life support in patients with acute myocardial infarction complicated by cardiogenic shock

    by Taek Kyu Park, Jeong Hoon Yang, Seung-Hyuk Choi, Young Bin Song, Joo-Yong Hahn, Jin-Ho Choi, Kiick Sung, Young Tak Lee, Hyeon-Cheol Gwon

    There is no available data on clinical outcome in patients with acute myocardial infarction (AMI) complicated by cardiogenic shock who are supported by an intra-aortic balloon pump (IABP) in combination with extracorporeal life support (ECLS).