Neha Dwivedi
Neha Dwivedi has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
Anil Kumar Nagarajappa
Department of Oral Medicine and Radiology, Hitkarini Dental College and Hospital, Jabalpur, Madhya Pradesh, India
1 shared publication- Anil Kumar Nagarajappa
Oral Medicine and Radiology, Department of Oral and Maxillofacial Surgery and Diagnostic Sciences, College of Dentistry, Jouf University, Sakaka, Saudi Arabia
1 shared publication Rana Tiwari
Department of Orthodontica and Dentofacial Orthopedics, Hitkarini Dental College and Hospital, Jabalpur, Madhya Pradesh, India
1 shared publication
Latest Publications
- Open Access
- 1 January 2016
- Published by Medknow in Journal of International Society of Preventive and Community Dentistry
- Vol. 6 (5) , 417-422
Morphological analysis of palatal rugae pattern in central Indian population
Aim: The aim of this study was to analyze the morphological study of palatal rugae pattern in a central Indian population and to determine sex differentiation. Objectives: To investigate the distinctive rugae patterns of the study population and determine the contribution of rugae patterns in gender identification. Material and Methods: The present cross-sectional study was conducted among a Central Indian population with a sample size of 500 participants. The study involved 250 males and 250 females who were randomly selected from the outpatient department of Oral Medicine Diagnosis and Radiology, Hitkarini Dental College and Hospital, Jabalpur, Madhya Pradesh. After collection of impression, casts were made and analyzed to evaluate the palatal rugae pattern in a central Indian population by using Thomas and Kotze classification (1983) for number, shape, direction, and unification of palatal rugae pattern. The statistical analysis was carried out using Mann–Whitney test and Chi-square (χ2) tests for categorical variables. Result: Males showed more number of rugae than females [P = 0.00 (≤0.001)]. Males had more number of wavy rugae pattern whereas females showed more number of straight rugae patterns [P = 0.00 (≤0.001)]. Males showed more backwardly directed rugae whereas females showed more forwardly directed rugae [P = 0.00 (≤0.001)]. The unification did not show any significant difference. Conclusion: This study showed that there was a significant relationship between palatoscopy, human identification, and sex determination. Thus, palatoscopy can be considered as a cost effective, easy, unique, and stable method for human identification.
- 1 January 2016
- Published by Medknow in Journal of International Society of Preventive and Community Dentistry
- Vol. 6 (5) , 417-422
Open AccessMorphological analysis of palatal rugae pattern in central Indian population
Aim: The aim of this study was to analyze the morphological study of palatal rugae pattern in a central Indian population and to determine sex differentiation. Objectives: To investigate the distinctive rugae patterns of the study population and determine the contribution of rugae patterns in gender identification. Material and Methods: The present cross-sectional study was conducted among a Central Indian population with a sample size of 500 participants. The study involved 250 males and 250 females who were randomly selected from the outpatient department of Oral Medicine Diagnosis and Radiology, Hitkarini Dental College and Hospital, Jabalpur, Madhya Pradesh. After collection of impression, casts were made and analyzed to evaluate the palatal rugae pattern in a central Indian population by using Thomas and Kotze classification (1983) for number, shape, direction, and unification of palatal rugae pattern. The statistical analysis was carried out using Mann–Whitney test and Chi-square (χ2) tests for categorical variables. Result: Males showed more number of rugae than females [P = 0.00 (≤0.001)]. Males had more number of wavy rugae pattern whereas females showed more number of straight rugae patterns [P = 0.00 (≤0.001)]. Males showed more backwardly directed rugae whereas females showed more forwardly directed rugae [P = 0.00 (≤0.001)]. The unification did not show any significant difference. Conclusion: This study showed that there was a significant relationship between palatoscopy, human identification, and sex determination. Thus, palatoscopy can be considered as a cost effective, easy, unique, and stable method for human identification.
- Open Access
- 1 January 2015
- Published by Medknow in Journal of International Society of Preventive and Community Dentistry
- Vol. 5 (6) , 440-5
Artifacts: The downturn of CBCT image
Cone-beam computed tomography (CBCT) has been accepted as a useful tool for diagnosis and treatment planning in dentistry. Despite a growing trend of CBCT in dentistry, it has some disadvantages like artifacts. Artifacts are discrepancies between the reconstructed visual image and the actual content of the subject which degrade the quality of CBCT images, making them diagnostically unusable. Additionally, structures that do not exist in the subject may appear within images. Such structures can occur because of patient motion, the image capture and reconstruction process. To optimize image quality, it is necessary to understand the types of artifacts. This article aims to throw light on the various types of artifacts associated with CBCT images.
- 1 January 2015
- Published by Medknow in Journal of International Society of Preventive and Community Dentistry
- Vol. 5 (6) , 440-5
Open AccessArtifacts: The downturn of CBCT image
Cone-beam computed tomography (CBCT) has been accepted as a useful tool for diagnosis and treatment planning in dentistry. Despite a growing trend of CBCT in dentistry, it has some disadvantages like artifacts. Artifacts are discrepancies between the reconstructed visual image and the actual content of the subject which degrade the quality of CBCT images, making them diagnostically unusable. Additionally, structures that do not exist in the subject may appear within images. Such structures can occur because of patient motion, the image capture and reconstruction process. To optimize image quality, it is necessary to understand the types of artifacts. This article aims to throw light on the various types of artifacts associated with CBCT images.