LÁLuis Carlos Álvarez

Luis Carlos Álvarez

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Luis Carlos Álvarez has a total of 144 co-authors. Here are the top co-authors by number of shared publications:

  • Oscar Chapa

    Universidad Nacional Autónoma de México, Instituto de Astronomía, Ciudad Universitaria, Mexico City, Mexico

    7 shared publications
  • Alan M. Watson

    Univ. Nacional Autónoma de México (Mexico)

    5 shared publications
  • Beatriz Sánchez

    Universidad Nacional Autónoma de México, Instituto de Astronomía, Ciudad Universitaria, Mexico City, Mexico

    5 shared publications
  • Salvador Cuevas

    Univ. Nacional Autónoma de México (Mexico)

    5 shared publications
  • Carlos Espejo

    Universidad Nacional Autónoma de México, Instituto de Astronomía, Ciudad Universitaria, Mexico City, Mexico

    4 shared publications
  • Gerardo Lara

    Universidad Nacional Autónoma de México, Instituto de Astronomía, Ciudad Universitaria, Mexico City, Mexico

    4 shared publications

Latest Publications

  • Open Access

    Cryogenic application of an autocentering mount working at the diffraction limit

    by Beatriz Sánchez, Carolina Keiman, Jorge Fuentes-Fernández, Salvador Cuevas, Carlos Espejo, Oscar Chapa, Rubén Flores-Meza, Luis Carlos Álvarez, Gerardo Lara, Leonardo Garcés

    We present the design concept and validation of a cryogenic lens mount for a noncemented doublet for the near-infrared diffraction limited instrument FRIDA. The design uses an autocentering mount that maintains the relative alignment of the lenses, acting against any displacement that may be induced by external forces by automatically returning the lenses to their nominal positions. Autocentering techniques have been used for instruments at room temperature with relatively relaxed image quality requirements. We present in detail its application to a mount for a cryogenic instrument working at the diffraction limit. The design has been tested on the collimator of FRIDA, a noncemented doublet of CaF2 and S-FTM16. We describe the alignment requirements of the system, and we show the calculations that ensure that the lenses will suffer both appropriate stresses and temperature differences. We present the experimental validation of a prototype, demonstrating that the design delivers an excellent performance without inducing unnecessary stresses on the optical components, provided that the lenses are previously aligned with very high precision.


  • FRIDA: diffraction-limited imaging and integral-field spectroscopy for the GTC

    by Alan M. Watson, José A. Acosta-Pulido, Luis C. Álvarez-Núñez, Vicente Bringas-Rico, Nicolás Cardiel, Salvador Cardona, Oscar Chapa, José Javier Díaz García, Stephen S. Eikenberry, Carlos Espejo, et al.

    FRIDA is a diffraction-limited imager and integral-field spectrometer that is being built for the adaptive-optics focus of the Gran Telescopio Canarias. In imaging mode FRIDA will provide scales of 0.010, 0.020 and 0.040 arcsec/pixel and in IFS mode spectral resolutions of 1500, 4000 and 30,000. FRIDA is starting systems integration and is scheduled to complete fully integrated system tests at the laboratory by the end of 2017 and to be delivered to GTC shortly thereafter. In this contribution we present a summary of its design, fabrication, current status and potential scientific applications.Comment: To appear in the proceedings of SPIE conference 9908 "Ground-based and Airborne Instrumentation for Astronomy VI". 8 page


  • Systems design of COATLI: an all-sky robotic optical imager with 0.3 arcsec image quality

    by Salvador Cuevas, Rosalia Langarica, Alan M. Watson, Jorge Fuentes-Fernández, Fernando Ángeles, Alejandro S. Farah, Liliana Figueroa, Rosa L. Becerra-Godínez, Oscar Chapa, Carlos G. Román-Zúñiga, et al.


  • COATLI: an all-sky robotic optical imager with 0.3 arcsec image quality

    by Alan M. Watson, Salvador Cuevas Cardona, Luis C. Alvarez Nuñez, Fernando Ángeles, Rosa L. Becerra-Godínez, Oscar Chapa, Alejandro S. Farah, Jorge Fuentes-Fernández, Liliana Figueroa, Rosalía Langarica Lebre, et al.

    COATLI will provide 0.3 arcsec FWHM images from 550 to 900 nm over a large fraction of the sky. It consists of a robotic 50-cm telescope with a diffraction-limited fast-guiding imager. Since the telescope is small, fast guiding will provide diffraction-limited image quality over a field of at least 1 arcmin and with coverage of a large fraction of the sky, even in relatively poor seeing. The COATLI telescope will be installed at the at the Observatorio Astron\'omico Nacional in Sierra San Pedro M\'artir, M\'exico, during 2016 and the diffraction-limited imager will follow in 2017.Comment: To appear in the proceedings of SPIE conference 9908 "Ground-based and Airborne Instrumentation for Astronomy VI". 9 page


  • Applications of variable focus liquid lenses for curvature wave-front sensors in astronomy

    by J. Fuentes-Fernández, S. Cuevas, L. C. Alvarez-Nuñez, A. M. Watson

    Curvature wavefront sensors obtain the wave-front aberrations from two defocused intensity images at each side of the pupil plane. Typically, when high modulation speeds are required, as it is the case with Adaptive Optics, that defocusing is done with a fast vibrating membrane mirror. We propose an alternative defocusing mechanism based on an electrowetting variable focus liquid lens. The use of such lenses may perform the required focus modulation without the need of extra moving parts, reducing the overall size of the system.

  • FRIDA diffraction limited NIR instrument: the challenges of its verification processes

    by Be. Sánchez, C. Keiman, C. Espejo, S. Cuevas, L. C. Álvarez, O. Chapa, R. Flores-Meza, J. Fuentes, L. Garcés, G. Lara, et al.

    FRIDA (inFRared Imager and Dissector for the Adaptive optics system of the Gran Telescopio Canarias (GTC)) is designed as a diffraction limited instrument that will offer broad and narrow band imaging and integral field spectroscopy capabilities with low, intermediate and high (R ~ 30,000) spectral resolutions, to operate in the wavelength range 0.9 – 2.5 μm. The integral field unit is based on a monolithic image slicer and the imaging and IFS observing modes will use the same Teledyne 2Kx2K detector. FRIDA will be based on a Nasmyth B of GTC, behind the adaptive optics (AO) system. The key scientific objectives of the instrument include studies of solar system bodies, low mass objects, circumstellar outflow phenomena in advanced stages of stellar evolution, active galactic nuclei high redshift galaxies, including resolved stellar populations, semidetached binary systems, young stellar objects and star forming environments. FRIDA subsystems are presently being manufactured and tested. In this paper we present the challenges to perform the verification of some critical specifications of a cryogenic and diffraction limited NIR instrument as FRIDA. FRIDA is a collaborative project between the main GTC partners, namely, Spain, México and Florida.


  • FRIDA, the diffraction limited NIR imager and IFS for the Gran Telescopio Canarias: status report

    by J. A. López, J. Acosta, L. C. Alvarez, V. Bringas, N. Cardiel, D. M. Clark, A. Corrales, S. Cuevas, O. Chapa, J. J. Díaz Garcia, et al.

    FRIDA is a diffraction limited imager and integral field spectrometer that is being built for the Gran Telescopio Canarias. FRIDA has been designed and is being built as a collaborative project between institutions from México, Spain and the USA. In imaging mode FRIDA will provide scales of 0.010, 0.020 and 0.040 arcsec/pixel and in IFS mode spectral resolutions R ~ 1000, 4,500 and 30,000. FRIDA is starting systems integration and is scheduled to complete fully integrated system tests at the laboratory by the end of 2015 and be delivered to GTC shortly after. In this contribution we present a summary of its design, fabrication, current status and potential scientific applications.


  • Tests and evaluation of a variable focus liquid lens for curvature wavefront sensors in astronomy

    by Jorge Fuentes-Fernández, Salvador Cuevas, Luis C. Álvarez-Nuñez, Alan Watson

    Curvature wavefront sensors (WFSs), which obtain the wavefront aberrations from two defocused intensity images at each side of the pupil plane, have shown to be highly efficient for astronomical applications. We propose here an alternative defocusing mechanism for curvature sensors, based on an electrowetting-based variable focus liquid lens. Typically, the sampling rates of a WFS for active optics are of the order of 0.01 Hz, and the focus modulation can be done by simply moving the detector back and forth. On the other hand, adaptive optics may require speeds of up to several hundred hertz, and the modulation is then done by using a fast vibrating membrane mirror. We believe variable focus liquid lenses may be able to perform this focus modulation, reducing the overall size of the system and without the need of extra moving parts. We have done a full characterization of the Varioptic Arctic 416 liquid lens, and we have evaluated its potential performance in different curvature configurations.


  • First Light with RATIR: An Automated 6-band Optical/NIR Imaging Camera

    by Nat Butler, Chris Klein, Ori Fox, Gennadiy Lotkin, Josh Bloom, J. Xavier Prochaska, Enrico Ramirez-Ruiz, José A. de Diego, Leonid Georgiev, Jesús González, et al.


  • Current status of FRIDA: diffraction limited NIR instrument for the GTC

    by Beatriz Sánchez, José A. Acosta, Luis Carlos Álvarez, Vicente Bringas, Nicolás Cardiel, Adi Corrales, Salvador Cuevas, Oscar Chapa, José Javier Díaz, Stephen S. Eikenberry, et al.

    FRIDA (inFRared Imager and Dissector for the Adaptive optics system of the Gran Telescopio Canarias) is designed as a diffraction limited instrument that will offer broad and narrow band imaging and integral field spectroscopy capabilities with low (R ~ 1,500), intermediate (R ~ 4,500) and high (R ~ 30,000) spectral resolutions to operate in the wavelength range 0.9 - 2.5 μm. The integral field unit is based on a monolithic image slicer. The imaging and IFS observing modes will use the same Teledyne 2K x 2K detector. FRIDA will be based at the Nasmyth B platform of GTC, behind the AO system. The key scientific objectives of the instrument include studies of solar system bodies, low mass objects, circumstellar outflow phenomena in advanced stages of stellar evolution, active galactic nuclei, high redshift galaxies, resolved stellar populations, semi-detached binary systems, young stellar objects and star forming environments. FRIDA is a collaborative project between the main GTC partners, namely, Spain, México and Florida. In this paper, we present the status of the instrument design as it is currently being prepared for its manufacture, after an intensive prototypes' phase and design optimization. The CDR was held in September 2011.